Lucene search
K

31 matches found

CVE
CVE
added 2022/02/11 5:40 p.m.98 views

CVE-2020-14521

CVE-2020-14521 affects Mitsubishi Electric Factory Automation engineering software and is a vulnerability in unquoted search path or element (CWE-428) that can lead to remote code execution with high impact. Public sources indicate affected Mitsubishi products span a wide range of engineering uti...

9.8CVSS9.2AI score0.01263EPSS
Exploits0References2Affected Software41
Vulnrichment
Vulnrichment
added 2022/02/11 5:40 p.m.6 views

CVE-2020-14521 Mitsubishi Electric Factory Automation Engineering Products Unquoted Search Path or Element

Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition...

8.3CVSS9.5AI score0.01263EPSS
Exploits0References2
Positive Technologies
Positive Technologies
added 2022/02/11 12:0 a.m.5 views

PT-2022-8573 · Mitsubishi · Mitsubishi Electric Factory Automation Engineering

Name of the Vulnerable Software and Affected Versions: Mitsubishi Electric Factory Automation engineering software products affected versions not specified Description: The issue allows a malicious attacker to execute malicious code, potentially obtaining information, modifying information, and...

9.8CVSS7.1AI score0.01263EPSS
Exploits0References6
ICS
ICS
added 2020/07/30 12:0 a.m.242 views

Mitsubishi Electric Factory Automation Engineering Products (Update L)

1. EXECUTIVE SUMMARY CVSS v3 8.3 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: Mitsubishi Electric, Factory Automation Engineering products Vulnerability: Unquoted Search Path or Element 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update...

9.8CVSS7.6AI score0.01263EPSS
Exploits0References9
ICS
ICS
added 2020/07/30 12:0 a.m.447 views

ICSA-20-212-02_Mitsubishi Electric Multiple Factory Automation Engineering Software Products (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.3 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: Mitsubishi Electric, Multiple Factory Automation Engineering Software products Vulnerability: Permission Issues 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update...

9.8CVSS9.3AI score0.00827EPSS
Exploits0References2
ICS
ICS
added 2020/07/30 12:0 a.m.77 views

Mitsubishi Electric Factory Automation Products Path Traversal (Update C)

1. EXECUTIVE SUMMARY CVSS v3 8.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: Mitsubishi Electric, Factory Automation products Vulnerability: Path Traversal 2. UPDATE INFORMATION This updated advisory is a follow-up to the advisory update titled...

9.8CVSS9.5AI score0.02254EPSS
Exploits0References5
ICS
ICS
added 2020/06/30 12:0 a.m.185 views

Mitsubishi Electric Factory Automation Engineering Software Products

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Mitsubishi Electric Equipment: Factory Automation Engineering Software Products Vulnerabilities: Improper Restriction of XML External Entity Reference and Uncontrolled Resource Consumption 2. RISK...

7.5CVSS8.1AI score0.01431EPSS
Exploits0References5
Saint
Saint
added 2016/03/31 12:0 a.m.44 views

Wago Shell

Added: 03/31/2016 Background Wago PLCs are used in Factory and building automation. Wago ethernet PLCs are connected by IP and can be administered remotely. Problem Wago PLC devices use CoDeSyS protocols to program the device. If the programming ports are left open an attacker is able to upload,...

0.5AI score
Exploits0
Saint
Saint
added 2016/03/31 12:0 a.m.45 views

Wago Shell

Added: 03/31/2016 Background Wago PLCs are used in Factory and building automation. Wago ethernet PLCs are connected by IP and can be administered remotely. Problem Wago PLC devices use CoDeSyS protocols to program the device. If the programming ports are left open an attacker is able to upload,...

7.5AI score
Exploits0
Saint
Saint
added 2016/03/31 12:0 a.m.42 views

Wago Shell

Added: 03/31/2016 Background Wago PLCs are used in Factory and building automation. Wago ethernet PLCs are connected by IP and can be administered remotely. Problem Wago PLC devices use CoDeSyS protocols to program the device. If the programming ports are left open an attacker is able to upload,...

0.5AI score
Exploits0
exploitpack
exploitpack
added 2014/09/24 12:0 a.m.39 views

WS10 Data Server - SCADA Overflow (PoC)

WS10 Data Server - SCADA Overflow PoC Exploit Title: WS10 Data Server SCADA Exploit Overflow PoC Date: 09/23/2014 Author: Pedro Sánchez Version: 1.83 English Tested on: Windows 7 embedded. Notified the vendor, vendor never responded. In the new version this PoC stops working Vendor: Novus...

0.3AI score
Exploits0
Rows per page
Query Builder