26146 matches found
CVE-2026-10584 HTTPS Fallback to HTTP in Graph Explorer
Proxy server in Graph Explorer before 3.0.1 falls back to HTTP when certificate files are missing, which might allow remote threat actors to obtain sensitive information via interception of requests intended to be sent over HTTPS. To remediate this issue, users should upgrade to Graph Explorer...
EUVD-2026-34011
Proxy server in Graph Explorer before 3.0.1 falls back to HTTP when certificate files are missing, which might allow remote threat actors to obtain sensitive information via interception of requests intended to be sent over HTTPS. To remediate this issue, users should upgrade to Graph Explorer...
CVE-2026-10584 HTTPS Fallback to HTTP in Graph Explorer
Proxy server in Graph Explorer before 3.0.1 falls back to HTTP when certificate files are missing, which might allow remote threat actors to obtain sensitive information via interception of requests intended to be sent over HTTPS. To remediate this issue, users should upgrade to Graph Explorer...
EUVD-2019-20154
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...
PT-2026-45817
Name of the Vulnerable Software and Affected Versions Graph Explorer versions prior to 3.0.1 Description The proxy server falls back to HTTP when certificate files are missing. This behavior may allow remote threat actors to intercept requests intended for HTTPS and obtain sensitive information...
Graph Explorer 安全漏洞
Graph Explorer is an interactive web application for visual exploration of graph databases, open-sourced by Amazon Web Services. Previous versions of Graph Explorer, such as 3.0.1, contained security vulnerabilities. These vulnerabilities stemmed from the proxy server falling back to HTTP when th...
CVE-2019-25718
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...
CVE-2026-10173
A weakness has been identified in Orthanc Explorer 2 up to 1.12.0. The impacted element is an unknown function of the file WebApplication/src/components/StudyList.vue of the component URL Handler. This manipulation of the argument remote-source causes cross site scripting. It is possible to...
CVE-2019-25718 Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...
CVE-2019-25718
Affected product: Dräger Infinity Explorer C700. Vulnerability: privilege escalation allowing kiosk-mode escape to reach the underlying OS via a specific dialog interaction. Impact: attacker can break out of kiosk mode, gain OS control, and cause the Delta Family patient monitor display to show i...
CVE-2019-25718 Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...
CVE-2019-25718
Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...
Dräger Infinity Explorer C700 安全漏洞
The Dräger Infinity Explorer C700 is an integrated medical-grade monitoring workstation component developed by the German company Dräger. The Dräger Infinity Explorer C700 has a security vulnerability that stems from privilege escalation. This vulnerability could allow attackers to break through...
CVE-2026-10173
A weakness has been identified in Orthanc Explorer 2 up to 1.12.0. The impacted element is an unknown function of the file WebApplication/src/components/StudyList.vue of the component URL Handler. This manipulation of the argument remote-source causes cross site scripting. It is possible to...
CVE-2026-10173
A weakness has been identified in Orthanc Explorer 2 up to 1.12.0. The impacted element is an unknown function of the file WebApplication/src/components/StudyList.vue of the component URL Handler. This manipulation of the argument remote-source causes cross site scripting. It is possible to...
EUVD-2026-33493
A weakness has been identified in Orthanc Explorer 2 up to 1.12.0. The impacted element is an unknown function of the file WebApplication/src/components/StudyList.vue of the component URL Handler. This manipulation of the argument remote-source causes cross site scripting. It is possible to...
CVE-2026-10173
Technical details (affected product/version, root cause, exploitation specifics) are not publicly available in the provided documents. Monitor for updates.
CVE-2026-10173 Orthanc Explorer 2 URL StudyList.vue cross site scripting
A weakness has been identified in Orthanc Explorer 2 up to 1.12.0. The impacted element is an unknown function of the file WebApplication/src/components/StudyList.vue of the component URL Handler. This manipulation of the argument remote-source causes cross site scripting. It is possible to...
CVE-2026-10173 Orthanc Explorer 2 URL StudyList.vue cross site scripting
A weakness has been identified in Orthanc Explorer 2 up to 1.12.0. The impacted element is an unknown function of the file WebApplication/src/components/StudyList.vue of the component URL Handler. This manipulation of the argument remote-source causes cross site scripting. It is possible to...
CVE-2026-10173 Orthanc Explorer 2 URL StudyList.vue cross site scripting
A weakness has been identified in Orthanc Explorer 2 up to 1.12.0. The impacted element is an unknown function of the file WebApplication/src/components/StudyList.vue of the component URL Handler. This manipulation of the argument remote-source causes cross site scripting. It is possible to...