CVE-2022-32520
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-2988
A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC Versions prior to V2.1.0, EcoStruxure Machine Expert – HVAC Versions prior to V1.4.0...
CVE-2022-32748
A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise...
CVE-2022-32518
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-45788
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...
CVE-2022-2988
A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC Versions prior to V2.1.0, EcoStruxure Machine Expert – HVAC Versions prior to V1.4.0...
CVE-2022-32519
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-32521
A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-45788
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...
CVE-2022-45788: Improper Check for Unusual or Exceptional Conditions
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...
CVE-2022-32518
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-2988
The CVE-2022-2988 entry concerns a CWE-787 Out-of-bounds Write vulnerability in Schneider Electric SoMachine HVAC and EcoStruxure Machine Expert – HVAC. Affects SoMachine HVAC prior to V2.1.0 and EcoStruxure Machine Expert – HVAC prior to V1.4.0. Root cause/impact: when a malicious web page is ac...
CVE-2022-32518
CVE-2022-32518 affects Schneider Electric Data Center Expert prior to version 7.9.0. It is a CWE-522 Insufficiently Protected Credentials flaw that could allow unauthorized access to a DCE instance over a network by a malicious third party. The vulnerability impact is described as high/critical i...
CVE-2022-32520
The CVE-2022-32520 entry affects Schneider Electric Data Center Expert before version 7.9.0. It describes a CWE-522 vulnerability (insufficiently protected credentials) that could allow a malicious remote actor to gain unauthorized access to a DCE instance over a network. The connected sources co...
CVE-2022-32747: Authentication Bypass by Spoofing
A CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause legitimate users to be locked out of devices or facilitate backdoor account creation by spoofing a device on the local network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert CAE Versions prior to 2.2...
CVE-2022-32519
CVE-2022-32519 affects Schneider Electric StruxureWare Data Center Expert prior to V7.9.0. The root cause is storing passwords in a recoverable format, which could allow a malicious third party to gain unauthorized, potentially full control over a DCE instance when accessed over a network. Affect...
CVE-2022-32519: Storing Passwords in a Recoverable Format
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-32520
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-32518: Insufficiently Protected Credentials
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert Versions prior to V7.9.0...
CVE-2022-32748
A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise...