Lucene search
+L

267 matches found

ICS
ICS
added 2016/07/31 6:0 a.m.73 views

Honeywell Experion PKS Improper Input Validation Vulnerability

OVERVIEW Honeywell reported a denial-of-service condition caused by an improper input validation vulnerability in Honeywell’s Experion Process Knowledge System PKS platform. Honeywell has produced patches to mitigate this vulnerability. This vulnerability could be exploited remotely. AFFECTED...

4.3CVSS4.5AI score0.01546EPSS
Exploits0References10
ThreatPost
ThreatPost
added 2015/09/30 11:21 a.m.15 views

Honeywell Experion PKS Security Vulnerabilities

Update – Unsupported versions of Honeywell distributed control system software are vulnerable to publicly available remote exploits. The Industrial Control System Cyber Emergency Response Team ICS-CERT published on Tuesday an advisory warning organizations to upgrade to supported versions of...

0.5AI score
Exploits0References3
ICS
ICS
added 2015/07/02 6:0 a.m.88 views

Honeywell Experion PKS Directory Traversal Vulnerability

OVERVIEW Independent researcher Joel Langill identified a directory traversal vulnerability in Honeywell’s Experion PKS application. This vulnerability exists in all unsupported phased out versions of the application that is still in use by some customers. Honeywell has recommended users of the...

5CVSS6.9AI score0.10361EPSS
Exploits6References10
ICS
ICS
added 2014/09/20 6:0 a.m.164 views

Honeywell Experion PKS Vulnerabilities

OVERVIEW Alexander Tlyapov, Gleb Gritsai, Kirill Nesterov, Artem Chaykin and Ilya Karpov of the Positive Technologies Research Team and Security Lab have identified vulnerabilities in Honeywell’s Experion Process Knowledge System EPKS application. Honeywell has produced several patch updates...

10CVSS10AI score0.05234EPSS
Exploits0References10
Prion
Prion
added 2012/09/08 10:28 a.m.11 views

Stack overflow

Stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control in Honeywell Process Solutions HPS Experion R2xx, R30x, R31x, and R400.x; Honeywell Building Solutions HBS Enterprise Building Manager R400 and R410.1; and Honeywell Environmental Combustion and Controls ECC Symmetr...

7.5CVSS8.8AI score0.04083EPSS
Exploits0References2Affected Software3
CVE
CVE
added 2012/09/08 10:0 a.m.54 views

CVE-2012-0254

CVE-2012-0254 denotes a stack-based buffer overflow in the HMIWeb Browser HSCDSPRenderDLL ActiveX control, affecting Honeywell HPS Experion (R2xx, R30x, R31x, R400.x); HBS Enterprise Building Manager (R400, R410.1); and ECC SymmetrE (R410.1). The vulnerability can allow remote attackers to execut...

7.5CVSS8.3AI score0.04083EPSS
Exploits0References2Affected Software3
ICS
ICS
added 2012/03/02 7:0 a.m.65 views

Honeywell HMIWeb Browser Buffer Overflow Vulnerability

OVERVIEW This advisory was originally posted on the the US-CERT secure portal library titled ICSA-12-150-01P Honeywell HMIWeb Browser Buffer Overflow Vulnerability to allow customers time to download the vendor patch prior to full public disclosure. ICS-CERT received a report from Honeywell and t...

7.5CVSS7.5AI score0.04083EPSS