EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2019-16369

Malware in sbrugna...

9.1CVSS9.3AI score0.00374EPSS
Exploits0References2
RedhatCVE
RedhatCVE
added 2025/05/22 8:47 a.m.4 views

CVE-2019-6815

In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration when using Ethernet/IP protocol...

9.1CVSS7.2AI score0.00374EPSS
Exploits0References1
SUSE CVE
SUSE CVE
added 2023/02/15 4:28 a.m.1 views

SUSE CVE-2018-10244

Suricata version 4.0.4 incorrectly handles the parsing of an EtherNet/IP PDU. A malformed PDU can cause the parsing code to read beyond the allocated data because DecodeENIPPDU in app-layer-enip-commmon.c has an integer overflow during a length check...

9.8CVSS9.5AI score0.00668EPSS
Exploits0References3
CVE
CVE
added 2019/05/22 7:52 p.m.63 views

CVE-2019-6815

The CVE-2019-6815 entry concerns Modicon Quantum PLCs (all firmware versions) with CWE-264 (Permissions, Privileges, and Access Control). The vulnerability arises via Ethernet/IP, enabling denial of service or unauthorized modifications of the PLC configuration due to improper access control. Doc...

9.1CVSS9AI score0.00374EPSS
Exploits0References1Affected Software1
OpenVAS
OpenVAS
added 2018/12/12 12:0 a.m.31 views

Rockwell Automation MicroLogix Detection (EtherNet/IP)

Detection of Rockwell Automation MicroLogix PLC SPDX-FileCopyrightText: 2018 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

7AI score
Exploits0
Positive Technologies
Positive Technologies
added 2013/01/24 12:0 a.m.4 views

PT-2013-1950

Name of the Vulnerable Software and Affected Versions Rockwell Automation EtherNet/IP products versions 18 and earlier Rockwell Automation EtherNet/IP products versions 19 and earlier Rockwell Automation EtherNet/IP products versions 20 and earlier 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB...

7.8CVSS5.5AI score0.07783EPSS
Exploits0References9