3132 matches found
Siemens SENTRON 7KT PAC1260 Data Manager Access Control Error Vulnerability
Siemens SENTRON 7KT PAC1260 Data Manager is a device for power monitoring and energy management from Siemens Germany. An Access Control Error vulnerability exists in the Siemens SENTRON 7KT PAC1260 Data Manager, which originates from an unauthenticated SSH service enabled endpoint, and can be...
PT-2025-29017
Name of the Vulnerable Software and Affected Versions: Linux kernel affected versions not specified Description: A potential division-by-zero error exists in the em compute costs function within the Linux kernel’s power management PM and energy management EM subsystems. This occurs when a non-CPU...
CVE-2025-31950
An unauthenticated attacker can obtain EV charger energy consumption information of other users...
CVE-2025-31147
Unauthenticated attackers can query information about total energy consumed by EV chargers of arbitrary users...
CVE-2025-31950
An unauthenticated attacker can obtain EV charger energy consumption information of other users...
CVE-2025-31147
Unauthenticated attackers can query information about total energy consumed by EV chargers of arbitrary users...
CVE-2025-31950
An unauthenticated attacker can obtain EV charger energy consumption information of other users...
CVE-2025-31147
Unauthenticated attackers can query information about total energy consumed by EV chargers of arbitrary users...
CVE-2025-31147 Growatt Cloud portal Authorization Bypass Through User-Controlled Key
Unauthenticated attackers can query information about total energy consumed by EV chargers of arbitrary users...
CVE-2025-31147
The CVE-2025-31147 entry corresponds to an information-disclosure vulnerability in Growatt Cloud Applications (China), affecting versions up to 3.6.0 and earlier. An unauthenticated attacker can query the total energy consumption information of arbitrary users’ EV chargers, exposing sensitive usa...
CVE-2025-31950 Growatt Cloud portal Authorization Bypass Through User-Controlled Key
An unauthenticated attacker can obtain EV charger energy consumption information of other users...
CVE-2025-31950 Growatt Cloud portal Authorization Bypass Through User-Controlled Key
An unauthenticated attacker can obtain EV charger energy consumption information of other users...
CVE-2025-31950
Growatt Cloud Applications (affected: version 3.6.0 and earlier) exposes an information-disclosure vulnerability allowing an unauthenticated attacker to obtain other users’ EV charger energy consumption data. Root cause: improper access control enabling retrieval of sensitive energy data. Impact ...
Growatt Cloud Applications 安全漏洞
Growatt Cloud Applications is a monitoring platform from Growatt in China. An information disclosure vulnerability exists in Growatt Cloud Applications version 3.6.0 and prior versions, which can be exploited by an unauthenticated attacker to obtain information about another user's electric vehic...
Growatt Cloud Applications 安全漏洞
Growatt Cloud Applications is a monitoring platform from Growatt in China. An information disclosure vulnerability exists in Growatt Cloud Applications version 3.6.0 and prior versions, which can be exploited by an unauthenticated attacker to query the total energy consumption information of any...
Hitachi Energy's RTU500 series NULL Pointer Deference (CVE-2024-10037)
A vulnerability exists in the RTU500 web server com- ponent that can cause a denial of service to the RTU500 CMU application if a specially crafted mes- sage sequence is executed on a WebSocket connec- tion. An attacker must be properly authenticated and the test mode function of RTU500 must be...
Hitachi Energy's RTU500 series Insufficient Resource Pool (CVE-2024-12169)
A vulnerability exists in RTU500 IEC 60870-5-104 con- trolled station functionality and IEC 61850 functional- ity, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerabil- ity only applies, if secure communication using IEC 62351-3 TLS is enabled...
Hitachi Energy's RTU500 series NULL Pointer Deference (CVE-2024-11499)
A vulnerability exists in RTU500 IEC 60870-4-104 con- trolled station functionality, that allows an authenti- cated and authorized attacker to perform a CMU re- start. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will...
ABB Cylon Aspect 3.07.01 - Hard-coded Default Credentials
Exploit Title : ABB Cylon Aspect 3.07.01 - Hard-coded Default Credentials Vendor: ABB Ltd. Product web page: https://www.global.abb Affected version: NEXUS Series, MATRIX-2 Series, ASPECT-Enterprise, ASPECT-Studio Firmware: =3.07.01 Summary: ASPECT is an award-winning scalable building energy...
CISA Releases Two Industrial Control Systems Advisories
CISA released two Industrial Control Systems ICS advisories on April 1, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-091-01 Rockwell Automation Lifecycle Services with Veeam Backup and Replication...