3174 matches found
PYSEC-2026-1453 Home Assistant has Stored XSS vulnerability in Energy dashboard from Energy Entity Name
Summary An authenticated party can add a malicious name to the Energy entity, allowing for Cross-Site Scripting attacks against anyone who can see the Energy dashboard, when they hover over any information point The blue bar in the picture below An alternative, and more impactful scenario, is tha...
Hitachi Energy e-mesh EMS
SUMMARY Hitachi Energy is aware of a buffer overflow vulnerability that affects e-mesh EMS product versions listed in this document. Successful exploitation of this vulnerability could lead to a buffer overflow condition, potentially resulting in application outages denial of service and...
CVE-2026-10593
The Zephyr Bluetooth LE Audio Basic Audio Profile BAP unicast client mishandles peer-supplied ASE state notifications. In unicastclientepqosstate subsys/bluetooth/audio/bapunicastclient.c, the handler writes attacker-controlled QoS fields interval, framing, phy, sdu, rtn, latency, pd through the...
CVE-2026-53121
A flaw was found in the Linux kernel's amd-pstate driver. When the amdpstateeppcpuinit function fails to set the Energy Performance Preference EPP, it does not properly free a previously allocated data object. This oversight leads to a memory leak, which could result in resource exhaustion over...
PT-2026-51651
Name of the Vulnerable Software and Affected Versions Hubbell Aclara Metrum affected versions not specified Description The Cellular Web Interface contains a flaw where missing authentication allows unauthenticated attackers to manipulate critical device settings and disrupt operations. This issu...
CVE-2025-4994
The SafeLine SL6 and SL6+ devices integrated into elevator emergency intercom systems are vulnerable to an authentication bypass. This vulnerability allows attackers to bypass authentication requirements and access the device's configuration service via the Bluetooth Low Energy BLE interface...
CVE-2025-4994 Authentication Bypass for SafeLine SL6 and SL6+
The SafeLine SL6 and SL6+ devices integrated into elevator emergency intercom systems are vulnerable to an authentication bypass. This vulnerability allows attackers to bypass authentication requirements and access the device's configuration service via the Bluetooth Low Energy BLE interface...
CVE-2025-4994
CVE-2025-4994 affects SafeLine SL6 and SL6+ devices used in elevator emergency intercoms. A BLE-facing authentication bypass allows an attacker within wireless range to obtain unauthorized administrative access to the device configuration. Documented impact includes high affects on confidentialit...
EUVD-2025-210297
The SafeLine SL6 and SL6+ devices integrated into elevator emergency intercom systems are vulnerable to an authentication bypass. This vulnerability allows attackers to bypass authentication requirements and access the device's configuration service via the Bluetooth Low Energy BLE interface...
PT-2026-51287
Name of the Vulnerable Software and Affected Versions SafeLine SL6 affected versions not specified SafeLine SL6+ affected versions not specified Description SafeLine SL6 and SL6+ devices integrated into elevator emergency intercom systems contain an authentication bypass. This issue allows...
CVE-2026-52866
An attacker within BLE communication range can monopolize the device's only available BLE connection slot, preventing legitimate users or applications from establishing a connection...
CVE-2026-50034
An attacker within BLE communication range can passively intercept wireless traffic and obtain sensitive health-related information, including glucose measurement values...
CVE-2026-50034
An attacker within BLE communication range can passively intercept wireless traffic and obtain sensitive health-related information, including glucose measurement values...
CVE-2026-50034 Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Cleartext Transmission of Sensitive Information
An attacker within BLE communication range can passively intercept wireless traffic and obtain sensitive health-related information, including glucose measurement values...
CVE-2026-50034
The CVE-2026-50034 entry concerns Apollo Pharmacy’s APG-01 BT Blood Glucose Monitoring System. Affected component: the device’s BLE wireless channel, where the root cause is cleartext transmission of sensitive health data. An attacker inside BLE range can passively eavesdrop traffic, potentially ...
CVE-2026-52866
The CVE-2026-52866 entry concerns the Apollo Pharmacy Blood Glucose Monitoring System APG-01 with BT lacking authorization in BLE. The connected docs provide concrete details: an attacker in BLE range can monopolize the device’s only available BLE connection slot, blocking legitimate users/applic...
CVE-2026-52866
An attacker within BLE communication range can monopolize the device's only available BLE connection slot, preventing legitimate users or applications from establishing a connection...
PT-2026-50821
Name of the Vulnerable Software and Affected Versions Apollo Pharmacy Blood Glucose Monitoring System APG-01 affected versions not specified Description An attacker within Bluetooth Low Energy BLE communication range can passively intercept wireless traffic to obtain sensitive health-related...
PT-2026-50822
Name of the Vulnerable Software and Affected Versions Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT affected versions not specified Description An attacker within Bluetooth Low Energy BLE communication range can monopolize the only available BLE connection slot of the device. This...
Hitachi Energy RTU500 NULL Pointer Dereference (CVE-2026-24515)
In libexpat before 2.7.4, XMLExternalEntityParserCreate does not copy unknown encoding handler user data, causing Denial of Service impact. Product is only affected if IEC 61850 functionality is configured. This plugin only works with Tenable.ot. Please visit...