Lucene search
+L

3172 matches found

OSV
OSV
added 2017/04/28 5:59 p.m.6 views

CVE-2017-1141

IBM Insights Foundation for Energy 1.0, 1.5, and 1.6 could allow an authenticated user to obtain sensitive information from error messages. IBM X-Force ID: 121907...

4.3CVSS5.8AI score0.00773EPSS
SaveExploits0References2
NVD
NVD
added 2017/04/28 5:59 p.m.21 views

CVE-2017-1141

IBM Insights Foundation for Energy 1.0, 1.5, and 1.6 could allow an authenticated user to obtain sensitive information from error messages. IBM X-Force ID: 121907...

4.3CVSS4.2AI score0.00773EPSS
SaveExploits0References2
Prion
Prion
added 2017/04/28 5:59 p.m.14 views

Information disclosure

IBM Insights Foundation for Energy 1.0, 1.5, and 1.6 could allow an authenticated user to obtain sensitive information from error messages. IBM X-Force ID: 121907...

4CVSS4.1AI score0.00773EPSS
SaveExploits0References2Affected Software1
CVE
CVE
added 2017/04/28 5:00 p.m.59 views

CVE-2017-1141

IBM Insights Foundation for Energy versions 1.0, 1.5, and earlier (

4.3CVSS4.2AI score0.00773EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2017/04/28 5:00 p.m.27 views

CVE-2017-1141

IBM Insights Foundation for Energy 1.0, 1.5, and 1.6 could allow an authenticated user to obtain sensitive information from error messages. IBM X-Force ID: 121907...

4.2AI score0.00773EPSS
SaveExploits0References2
ICS
ICS
added 2017/04/04 12:00 a.m.58 views

Schneider Electric Interactive Graphical SCADA System Software

CVSS v3 6.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Schneider Electric Equipment: Interactive Graphical SCADA System IGSS Software Vulnerability: DLL Hijacking AFFECTED PRODUCTS Schneider Electric reports that the vulnerability affects the following IGSS HMI desktop...

7.8CVSS7.7AI score0.0134EPSS
SaveExploits0References3
ICS
ICS
added 2017/03/02 12:00 a.m.89 views

Schneider Electric Conext ComBox

CVSS v3 7.5 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Schneider Electric Equipment: Conext ComBox Vulnerability: Resource Exhaustion AFFECTED PRODUCTS Schneider Electric reports that the vulnerability affects the following Conext ComBox solar battery monitor: Conext...

7.8CVSS7.7AI score0.36943EPSS
SaveExploits4References3
NVD
NVD
added 2017/02/13 9:59 p.m.20 views

CVE-2016-5782

An issue was discovered in Locus Energy LGate prior to 1.05H, LGate 50, LGate 100, LGate 101, LGate 120, and LGate 320. Locus Energy meters use a PHP script to manage the energy meter parameters for voltage monitoring and network configuration. The PHP code does not properly validate information...

8.6CVSS8.6AI score0.0207EPSS
SaveExploits0References3
Prion
Prion
added 2017/02/13 9:59 p.m.13 views

Cross site request forgery (csrf)

An issue was discovered in Locus Energy LGate prior to 1.05H, LGate 50, LGate 100, LGate 101, LGate 120, and LGate 320. Locus Energy meters use a PHP script to manage the energy meter parameters for voltage monitoring and network configuration. The PHP code does not properly validate information...

7.5CVSS7AI score0.0207EPSS
SaveExploits0References3
CVE
CVE
added 2017/02/13 9:00 p.m.157 views

CVE-2016-5782

The CVE affects Locus Energy LGate devices (LGate firmware prior to 1.05H and models 50, 100, 101, 120, 320). The root cause is improper validation of POST data in the PHP-based web interface, enabling command injection via the LGate web server. Impact: remote, unauthenticated attackers could exe...

8.6CVSS8.4AI score0.0207EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2017/02/13 9:00 p.m.33 views

CVE-2016-5782

An issue was discovered in Locus Energy LGate prior to 1.05H, LGate 50, LGate 100, LGate 101, LGate 120, and LGate 320. Locus Energy meters use a PHP script to manage the energy meter parameters for voltage monitoring and network configuration. The PHP code does not properly validate information...

8.6AI score0.0207EPSS
SaveExploits0References3
Metasploit
Metasploit
added 2017/02/11 5:48 a.m.74 views

Carlo Gavazzi Energy Meters - Login Brute Force, Extract Info and Dump Plant Database

This module scans for Carlo Gavazzi Energy Meters login portals, performs a login brute force attack, enumerates device firmware version, and attempt to extract the SMTP configuration. A valid, admin privileged user is required to extract the SMTP password. In some older firmware versions, the SM...

7.5CVSS7AI score0.09317EPSS
SaveExploits2
ICS
ICS
added 2017/02/07 12:00 a.m.82 views

ICSA-17-038-01_Sielco Sistemi Winlog SCADA Software

CVSS v3 7.2 Vendor: Sielco Sistemi Equipment: Winlog SCADA Software Vulnerability: Uncontrolled Search Path Element AFFECTED PRODUCTS The following Sielco Sistemi products are affected: Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to...

9.3CVSS7.3AI score0.00938EPSS
SaveExploits1References2
ICS
ICS
added 2017/02/02 12:00 a.m.74 views

Honeywell XL Web II Controller Vulnerabilities

OVERVIEW Independent researcher Maxim Rupp has identified vulnerabilities in Honeywell’s XL Web II controller application. Honeywell has produced a new version to mitigate these vulnerabilities. These vulnerabilities could be exploited remotely. AFFECTED PRODUCTS The following XL Web II controlle...

9.8CVSS8.7AI score0.02251EPSS
SaveExploits0References2
The Hacker News
The Hacker News
added 2017/01/05 8:04 p.m.15 views

KillDisk Ransomware Targets Linux; Demands $250,000 Ransom, But Won't Decrypt Files

What you'll do if Ransomware infects you? Should you pay or not to recover your files? Believe me, the FBI advises - Pay off the criminals to get your files back if you don't have a backup. But paying off a ransom to cyber criminals is definitely not a wise option because there is no guarantee...

6.6AI score
SaveExploits0
Openbugbounty
Openbugbounty
added 2017/01/02 2:30 p.m.12 views

bordgaisenergy.ie XSS vulnerability

Vulnerable URL: http://www.bordgaisenergy.ie/search.php?q=moving=1=all=10=281 Details: Description| Value ---|--- Patched:| No Latest check for patch:| 30.07.2017 Vulnerability type:| XSS Vulnerability status:| Publicly disclosed Alexa Rank| 162422 VIP website status:| No Check bordgaisenergy.ie...

6.3AI score
SaveExploits0
ICS
ICS
added 2016/12/19 7:00 a.m.49 views

ABB Panel Builder 800 DLL Hijacking Vulnerability (Update A)

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-16-077-01 ABB Panel Builder 800 DLL Hijacking Vulnerability that was published March 17, 2016, on the NCCIC/ICS-CERT web site. Ivan Sanchez from Nullcode Team has identified a DLL Hijacking vulnerability in the ABB...

7.2CVSS7.3AI score0.00305EPSS
SaveExploits0References10
CNVD
CNVD
added 2016/12/09 12:00 a.m.9 views

Multiple Locus Energy LGate Products OS Command Injection Vulnerabilities

Locus Energy LGate is a web-based data collection system from Locus Energy, Inc. An input validation vulnerability exists in multiple Locus Energy LGate products, which allows remote attackers to submit a special request, inject and execute arbitrary commands...

8.6CVSS7.5AI score0.0207EPSS
SaveExploits0References1
ThreatPost
ThreatPost
added 2016/12/08 8:30 a.m.14 views

Some Solar Power Meters are Vulnerable to Command Injection Attacks

Solar software and analytics firm Locus Energy has pushed out a patch to its residential and commercial power meters to address a vulnerability that could allow hackers to access equipment and remotely execute code. According to independent security researcher Daniel Reich, who privately disclose...

0.7AI score
SaveExploits0References1
Openbugbounty
Openbugbounty
added 2016/12/03 9:44 p.m.11 views

cpsenergy.com XSS vulnerability

Vulnerable URL: https://cpsenergy.com/en/solrsearch.html?q=prompt/XSSPOSED/...

6.9AI score
SaveExploits0
Rows per page
Query Builder