Lucene search
+L

3173 matches found

BDU FSTEC
BDU FSTEC
added 2022/08/31 12:00 a.m.13 views

The vulnerability of microprogrammed software in industrial software-hardware equipment from General Electric’s Renewable Energy iNET, iNET II, TD220X, and TD220MAX models is related to uncontrolled resource consumption. This vulnerability allows a perpetrator to cause malfunctions in the equipment.

The vulnerability of microprogrammed software in industrial software-hardware equipment from General Electric’s Renewable Energy iNET, iNET II, TD220X, and TD220MAX models is related to uncontrolled resource consumption. Exploiting this vulnerability can allow attackers to cause malfunctions in t...

8CVSS7.7AI score0.00631EPSS
SaveExploits0References4Affected Software5
ThreatPost
ThreatPost
added 2022/08/30 4:00 p.m.72 views

Watering Hole Attacks Push ScanBox Keylogger

A China-based threat actor has ramped up efforts to distribute the ScanBox reconnaissance framework to victims that include domestic Australian organizations and offshore energy firms in the South China Sea. The bait used by the advanced threat group APT is targeted messages that supposedly link...

7.3AI score
SaveExploits0References8
ICS
ICS
added 2022/08/30 12:00 a.m.66 views

Hitachi Energy FACTS Control Platform (FCP) Product

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: FACTS Control Platform FCP Product Vulnerability: Inconsistent Interpretation of HTTP Requests, Use After Free, Classic Buffer Overflow, Integer Underflow, Improper Certificate...

9.3CVSS8AI score0.07646EPSS
SaveExploits2References5
ICS
ICS
added 2022/08/30 12:00 a.m.61 views

Hitachi Energy MSM Product

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: MSM Product Vulnerability: Reliance on Uncontrolled Component 2. RISK EVALUATION Successful exploitation of this vulnerability could disrupt the functionality of the MSM web...

9.1CVSS8.8AI score0.2258EPSS
SaveExploits3References5
ICS
ICS
added 2022/08/30 12:00 a.m.63 views

Hitachi Energy Gateway Station (GWS) Product

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: Gateway Station GWS Product Vulnerability: Inconsistent Interpretation of HTTP Requests, Use After Free, Classic Buffer Overflow, Integer Underflow, Improper Certificate...

4.3CVSS7.9AI score0.04764EPSS
SaveExploits0References5
ICS
ICS
added 2022/08/30 12:00 a.m.54 views

Hitachi Energy RTU500 series

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 series Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could cause an internal buffer overflow, which can...

7.8CVSS7.9AI score0.00951EPSS
SaveExploits0References5
CISA
CISA
added 2022/08/29 12:00 a.m.34 views

CISA Releases 12 Industrial Control Systems Advisories

CISA has released 12 Industrial Control Systems ICS advisories on August 30, 2022. These advisories provides timely information about current security issues, vulnerabilities, and exploits surrounding ICS. CISA encourages users and administrators to review the newly released ICS advisories for...

SaveExploits0References12
Openbugbounty
Openbugbounty
added 2022/08/27 9:18 a.m.22 views

yorkshireenergydoctor.org.uk Cross Site Scripting vulnerability OBB-2867916

Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...

6.2AI score
SaveExploits0
CNVD
CNVD
added 2022/08/26 12:00 a.m.70 views

Hitachi Energy RTU500 series CMU firmware buffer overflow vulnerability

RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A buffer overflow vulnerability exists in the Hitachi Energy RTU500 series CMU firmware HCI Modbus TCP function. The vulnerability, which originates when HCI Modbus TCP is enabled a...

7.5CVSS7.3AI score0.00636EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2022/08/23 12:00 a.m.10 views

PT-2022-4414 · Hitachi Energy · Rtu500

Name of the Vulnerable Software and Affected Versions: Hitachi Energy RTU500 versions affected versions not specified Description: The issue is related to a vulnerability in the HCI interface, functioning via the Modbus TCP protocol, which can cause a buffer overflow in memory. This can be...

7.8CVSS7.7AI score0.00636EPSS
SaveExploits0References7
ICS
ICS
added 2022/08/23 12:00 a.m.204 views

Measuresoft ScadaPro Server

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Measuresoft Equipment: ScadaPro Server Vulnerability: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of this vulnerability may allow arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The...

7.8CVSS7.8AI score0.00308EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2022/08/23 12:00 a.m.9 views

Hitachi Energy RTU500 安全漏洞

RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A buffer overflow vulnerability exists in the Hitachi Energy RTU500 series CMU firmware HCI Modbus TCP function. The vulnerability, which originates when HCI Modbus TCP is enabled a...

7.5CVSS7.1AI score0.00636EPSS
SaveExploits0References3
ICS
ICS
added 2022/08/23 12:00 a.m.81 views

Measuresoft ScadaPro Server and Client

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Measuresoft Equipment: ScadaPro Server and Client Vulnerabilities: Untrusted Pointer Dereference, Stack-based Buffer Overflow, Use After Free, Link Following. 2. RISK EVALUATION Successful exploitation of these...

7.8CVSS7.6AI score0.00323EPSS
SaveExploits0References5
ICS
ICS
added 2022/08/23 12:00 a.m.48 views

Hitachi Energy RTU500

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 Series Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to send a specially crafted...

7.5CVSS8AI score0.00636EPSS
SaveExploits0References5
hivepro
hivepro
added 2022/08/22 5:20 p.m.17 views

Iranian-linked hacker group victimized Israel’s shipping industry

Threat Level Actor Report For a detailed advisory, download the pdf file here Summary Iranian threat group UNC3890 used social engineering lures and a watering hole to jeopardize Israels shipping, government, energy, aviation, and healthcare sectors. This campaign has been running since at least...

1.6AI score
SaveExploits0
Openbugbounty
Openbugbounty
added 2022/08/17 3:47 a.m.12 views

energy-speakers.com Cross Site Scripting vulnerability OBB-2850965

Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...

6.2AI score
SaveExploits0
Rapid7 Blog
Rapid7 Blog
added 2022/08/10 1:30 p.m.16 views

Navigating the Evolving Patchwork of Incident Reporting Requirements

In March 2022, President Biden signed into law the Cyber Incident Reporting for Critical Infrastructure Act CIRCIA, a bipartisan initiative that empowers CISA to require cyber incident reporting from critical infrastructure owners and operators. Rapid7 is supportive of CIRCIA and cyber incident...

SaveExploits0
CNVD
CNVD
added 2022/08/09 12:00 a.m.67 views

Siemens SICAM A8000 Web Server Module Authentication Bypass Vulnerability

The SICAM A8000 RTU Remote Terminal Unit series is a modular device family for remote control and automation applications in all energy supply areas.An authentication bypass vulnerability exists in the Siemens SICAM A8000 Web Server Module, which is caused by the component allowing the activation...

7.5CVSS3AI score0.0067EPSS
SaveExploits0References1
ICS
ICS
added 2022/08/09 12:00 a.m.53 views

Siemens SICAM A8000 Web Server Module

1. EXECUTIVE SUMMARY CVSS v3 4.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SICAM A8000 CP-8000, CP-8021, CP-8022 Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow unauthenticated access to the...

7.5CVSS7.7AI score0.0067EPSS
SaveExploits0References11
Malwarebytes
Malwarebytes
added 2022/08/08 11:38 a.m.28 views

A week in security (August 1 – 7)

Last week on Malwarebytes Labs: Have we lost the fight for data privacy? Lock and Code S03E16 Wrestling star Mick Foley’s Twitter compromised, selling PS5 consoles Millions of Arris routers are vulnerable to path traversal attacks When a sextortion victim fights back How to protect yourself and...

1.7AI score
SaveExploits0
Rows per page