3173 matches found
Code injection
A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client...
CVE-2022-3353 IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products
A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client...
CVE-2022-3353 IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products
A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client...
CVE-2022-3353
CVE-2022-3353 affects Hitachi Energy devices operating the IEC 61850 MMS-Server across multiple product lines (FOX61x/TEGO1, GMS600, ITT600 SA Explorer, MICROSACDA X SYS600, MMS, PWC600, REB500, Relion 650/670/SAM600-IO, RTU500 CMU, TXpert Hub CoreTec 4/5, SYS600, and related variants). The vulne...
Hitachi Energy FOX61x 安全漏洞
The Hitachi Energy FOX61x series is an outstanding multi-service multiplexer from Hitachi, Japan that extends existing communication infrastructures and enables smooth migration to future technologies. A security vulnerability exists in Hitachi Energy FOX61x TEGO1, which stems from a problem in t...
PT-2023-13314 · Hitachi Energy · Hitachi Energy Products
Name of the Vulnerable Software and Affected Versions: Hitachi Energy products affected versions not specified fox61x tego1 versions r15b08 through r2a16 fox61x tego1 version r1e01 fox61x tego1 version r1d02 fox61x tego1 version r1c07 fox61x tego1 version r1b02 gms600 version 1.3.0 itt600 sa...
Friday Squid Blogging: Thermal Batteries from Squid Proteins
Researchers are making thermal batteries from "a synthetic material thats derived from squid ring teeth protein." As usual, you can also use this squid post to talk about the security stories in the news that I havent covered. Read my blog posting guidelines here...
Delta Electronics DIAEnergie 授权问题漏洞
Delta Electronics DIAEnergie is an industrial energy management system from Delta Electronics Taiwan, China used to monitor and analyze energy consumption in real time, calculate energy consumption and load characteristics, optimize equipment performance, improve production processes and maximize...
Hitachi Energy IEC 61850 MMS-Server (Update B)
1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Hitachi Energy Equipment: IEC 61850 MMS-Server Vulnerability: Improper Resource Shutdown or Release 2. RISK EVALUATION Successful exploitation of this vulnerability could cause products using the IEC 61850 MMS-server...
CVE-2022-4557
Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.This issue affects Smartpower Web: before 23.01.01...
CVE-2022-4557
Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection. This issue affects Smartpower Web: before 23.01.01...
CVE-2022-4557
Improper Neutralization of Special Elements used in an SQL Command 'SQL Injection' vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection. This issue affects Smartpower Web: before 23.01.01...
CVE-2022-45085
Server-Side Request Forgery SSRF vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery. This issue affects Smartpower Web: before 23.01.01...
CVE-2022-45085
Server-Side Request Forgery SSRF vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery.This issue affects Smartpower Web: before 23.01.01...
CVE-2022-45087
Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting XSS. This issue affects Smartpower Web: before 23.01.01...
CVE-2022-45089
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.This issue affects Smartpower Web: before 23.01.01...
CVE-2022-45089
Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection. This issue affects Smartpower Web: before 23.01.01...
CVE-2022-45086
Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting XSS. This issue affects Smartpower Web: before 23.01.01...
CVE-2022-45086
Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting XSS. This issue affects Smartpower Web: before 23.01.01...
CVE-2022-45091
Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting XSS. This issue affects Smartpower Web: before 23.01.01...