The vulnerabilities of HCI (Host Controller Interface) and SCI interfaces, which operate according to the IEC 60870-5-104 standard, and are found in Hitachi Energy RTU500 programmable logic controllers, allow a perpetrator to trigger a service failure.
The vulnerabilities of HCI Host Controller Interface and SCI interfaces, which operate according to the IEC 60870-5-104 standard, in Hitachi Energy RTU500 programmable logic controllers, are related to insufficient verification of input data. Exploiting these vulnerabilities can allow an attacker...
The vulnerability of the Bluetooth LE component of the microprogramming software for biometric locks, Ultraloq UL3 2nd Gen Smart Lock, allows a intruder to disclose the protected information.
The vulnerability of the Bluetooth LE component of the microprogrammed biometric lock Ultraloq UL3 2nd Gen Smart Lock is related to session management errors. Exploiting this vulnerability could allow a remote attacker to disclose the protected information...
The vulnerability of Hitachi Energy RTU500 CMU series programmable logic controllers’ web servers allows attackers to perform cross-site scripting attacks.
The vulnerability of the Hitachi Energy RTU500 CMU series programmable logic controllers’ web servers is related to the lack of protective measures for the website structure. Exploiting this vulnerability allows a remote attacker to perform cross-site scripting attacks...
Hitachi Energy RTU500 Scripting interface Trust Management Issue Vulnerability
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used for industrial control systems.RTU500 Scripting interface is part of Hitachi Energy RTU500 series of industrial control components, mainly used to provide scripting programming interface to realize specific...
EFACEC UC 500E
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : EFACEC Equipment : UC 500 Vulnerabilities : Cleartext Transmission of Sensitive Information, Open Redirect, Exposure of Sensitive Information to an Unauthorized Actor, Improper Access Contro...
EFACEC BCU 500
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.6 ATTENTION : Exploitable remotely/low attack complexity Vendor : EFACEC Equipment : BCU 500 Vulnerabilities : Uncontrolled Resource Consumption, Cross-site Request Forgery 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an...
SUSE CVE-2023-46447
The POPS! Rebel application 5.0 for Android, in POPS! Rebel Bluetooth Glucose Monitoring System, sends unencrypted glucose measurements over BLE...
The vulnerability of Hitachi Energy RTU500 CMU series programmable logic controllers’ web servers allows attackers to perform cross-site scripting attacks.
The vulnerability of the Hitachi Energy RTU500 CMU series programmable logic controllers’ web servers is related to the lack of protective measures for the website structure. Exploiting this vulnerability allows a remote attacker to perform cross-site scripting attacks...
Hitachi Energy RTU500 信任管理问题漏洞
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used for industrial control systems.RTU500 Scripting interface is part of Hitachi Energy RTU500 series of industrial control components, mainly used to provide scripting programming interface to realize specific...
Hitachi Energy RTU500 输入验证错误漏洞
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. An input validation error vulnerability exists in the Hitachi Energy RTU500 series CMU Firmware, which arises from a specially crafted message sent to the component that is not...
Hitachi Energy RTU500 series CMU Firmware Cross-Site Scripting Vulnerability (CNVD-2025-02739)
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A cross-site scripting vulnerability exists in Hitachi Energy RTU500 series CMU Firmware, which originates from user input not being properly cleaned, and can be exploited by an...
energy-powerhaus.de Improper Access Control vulnerability OBB-3816669
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
Hitachi Energy RTU500 跨站脚本漏洞
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A cross-site scripting vulnerability exists in Hitachi Energy RTU500 series CMU Firmware, which originates from user input not being properly cleaned, and can be exploited by an...
Hitachi Energy RTU500 series CMU Firmware Cross-Site Scripting Vulnerability
RTU500 is a series of industrial control components from Hitachi, Japan, mainly used in industrial control systems. A cross-site scripting vulnerability exists in Hitachi Energy RTU500 series CMU Firmware, which originates from an RDT language file that is not properly cleaned up, and can be...
Hitachi Energy RTU500 series CMU Firmware Denial of Service Vulnerability
Hitachi Energy RTU500 is a series of industrial control components from Hitachi, Japan. A denial of service vulnerability exists in Hitachi Energy RTU500 series CMU Firmware, which arises from an incomplete or incorrect layout of received APDU frames, and can be exploited by an attacker to cause ...
Russian FSB Cyber Actor Star Blizzard Continues Worldwide Spear-phishing Campaigns
The Russia-based actor is targeting organizations and individuals in the UK and other geographical areas of interest. OVERVIEW The Russia-based actor Star Blizzard formerly known as SEABORGIUM, also known as Callisto Group/TA446/COLDRIVER/TAG-53/BlueCharlie continues to successfully use...
BlueBunny - BLE Based C2 For Hak5's Bash Bunny
C2 solution that communicates directly over Bluetooth-Low-Energy with your Bash Bunny Mark II. Send your Bash Bunny all the instructions it needs just over the air. Overview Structure Installation & Start 1. Install required dependencies pip install pygatt "pygattGATTTOOL" Make sure BlueZ is...
Schweitzer Engineering Laboratories SEL-411L
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 4.3 ATTENTION : Exploitable remotely/low attack complexity Vendor : Schweitzer Engineering Laboratories Equipment : SEL-411L Vulnerability : Improper Restriction of Rendered UI Layers or Frames 2. RISK EVALUATION Successful exploitation of this vulnerability...
CVE-2023-46916
Maxima Max Pro Power 1.0 486A devices allow BLE traffic replay. An attacker can use GATT characteristic handle 0x0012 to perform potentially disruptive actions such as starting a Heart Rate monitor...
PT-2023-18914 · Undefined · Undefined
ParsedReport CompletenessMedium 07-12-2023 Fighting Ursa Aka APT28: Illuminating a Covert Campaign https://unit42.paloaltonetworks.com/russian-apt-fighting-ursa-exploits-cve-2023-233397 Report completeness: Medium Actors/Campaigns: Fancy bear Forest blizzard Threats: Wildfire Victims: Organizatio...