Lucene search
+L

1087 matches found

CNVD
CNVD
added 2021/05/21 12:00 a.m.34 views

Emerson Rosemount X-STREAM Gas Analyzer Path Traversal Vulnerability

The Emerson Rosemount X-STREAM Gas Analyzer is an Emerson gas analyzer for industrial environments. The device supports up to five component gas analyzers and features NDIR/UV/VIS photometry, paramagnetic and electrochemical O2, thermal conductivity and humidity sensors. A path traversal...

7.5CVSS6.7AI score0.01397EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/05/21 12:00 a.m.32 views

Emerson Rosemount X-STREAM Gas Analyzer Code Issue Vulnerability

The Emerson Rosemount X-STREAM Gas Analyzer is an Emerson gas analyzer for industrial environments. The device supports up to five component gas analyzers and features NDIR/UV/VIS photometry, paramagnetic and electrochemical O2, thermal conductivity and humidity sensors. The Emerson Rosemount...

9.8CVSS7.8AI score0.01752EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/05/21 12:00 a.m.12 views

Emerson Rosemount X-STREAM Gas Analyzer Cross-Site Scripting Vulnerability

The Emerson Rosemount X-STREAM Gas Analyzer is an Emerson gas analyzer for industrial environments. The device supports up to five component gas analyzers and features NDIR/UV/VIS photometry, paramagnetic and electrochemical O2, thermal conductivity and humidity sensors. A cross-site scripting...

6.1CVSS6.1AI score0.00642EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/05/21 12:00 a.m.15 views

Unspecified Vulnerability in Emerson Rosemount X-STREAM Gas Analyzer

The Emerson Rosemount X-STREAM Gas Analyzer is an Emerson gas analyzer for industrial environments. The device supports up to five component gas analyzers and features NDIR/UV/VIS photometry, paramagnetic and electrochemical O2, thermal conductivity and humidity sensors. A security vulnerability...

5.3CVSS6.7AI score0.009EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/05/21 12:00 a.m.9 views

Unspecified Vulnerability in Emerson Rosemount X-STREAM Gas Analyzer (CNVD-2021-37939)

The Emerson Rosemount X-STREAM Gas Analyzer is an Emerson gas analyzer for industrial environments. The device supports up to five component gas analyzers and features NDIR/UV/VIS photometry, paramagnetic and electrochemical O2, thermal conductivity and humidity sensors. A security vulnerability...

6.1CVSS6.9AI score0.00699EPSS
SaveExploits0References1
NVD
NVD
added 2021/05/20 12:15 p.m.18 views

CVE-2021-27461

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected webserver applications allow access to stored data that can be obtained by using specially crafted URLs...

7.5CVSS0.01397EPSS
SaveExploits0References1
NVD
NVD
added 2021/05/20 12:15 p.m.20 views

CVE-2021-27463

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications utilize persistent cookies where the session cookie attribute is not properly invalidated, allowing an attacker to intercept the cookies and gain access to sensitive...

5.3CVSS0.009EPSS
SaveExploits0References1
NVD
NVD
added 2021/05/20 12:15 p.m.15 views

CVE-2021-27459

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The webserver of the affected products allows unvalidated files to be uploaded, which an attacker could utilize to execute arbitrary code...

9.8CVSS0.01752EPSS
SaveExploits0References1
NVD
NVD
added 2021/05/20 12:15 p.m.20 views

CVE-2021-27467

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected product’s web interface allows an attacker to route click or keystroke to another page provided by the attacker to gain unauthorized access to sensitive information...

6.1CVSS0.00699EPSS
SaveExploits0References1
NVD
NVD
added 2021/05/20 12:15 p.m.27 views

CVE-2021-27457

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access...

7.5CVSS0.00452EPSS
SaveExploits0References1
NVD
NVD
added 2021/05/20 12:15 p.m.15 views

CVE-2021-27465

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications do not validate webpage input, which could allow an attacker to inject arbitrary HTML code into a webpage. This would allow an attacker to modify the page and display incorre...

6.1CVSS0.00642EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2021/05/20 12:15 p.m.6 views

CVE-2021-27457

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access...

7.5CVSS7.1AI score0.00452EPSS
SaveExploits0References2
Prion
Prion
added 2021/05/20 12:15 p.m.19 views

Design/Logic Flaw

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access...

5CVSS7.9AI score0.00452EPSS
SaveExploits0References1
Prion
Prion
added 2021/05/20 12:15 p.m.16 views

Code injection

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The webserver of the affected products allows unvalidated files to be uploaded, which an attacker could utilize to execute arbitrary code...

7.5CVSS9.6AI score0.01752EPSS
SaveExploits0References1
Prion
Prion
added 2021/05/20 12:15 p.m.17 views

Design/Logic Flaw

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications do not validate webpage input, which could allow an attacker to inject arbitrary HTML code into a webpage. This would allow an attacker to modify the page and display incorre...

4.3CVSS6.9AI score0.00642EPSS
SaveExploits0References1
Prion
Prion
added 2021/05/20 12:15 p.m.18 views

Design/Logic Flaw

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected webserver applications allow access to stored data that can be obtained by using specially crafted URLs...

5CVSS7.9AI score0.01397EPSS
SaveExploits0References1
Prion
Prion
added 2021/05/20 12:15 p.m.19 views

Information disclosure

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected product’s web interface allows an attacker to route click or keystroke to another page provided by the attacker to gain unauthorized access to sensitive information...

5.8CVSS7AI score0.00699EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2021/05/20 12:15 p.m.6 views

CVE-2021-27465

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications do not validate webpage input, which could allow an attacker to inject arbitrary HTML code into a webpage. This would allow an attacker to modify the page and display incorre...

6.1CVSS5.9AI score0.00642EPSS
SaveExploits0References2
Prion
Prion
added 2021/05/20 12:15 p.m.18 views

Information disclosure

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications utilize persistent cookies where the session cookie attribute is not properly invalidated, allowing an attacker to intercept the cookies and gain access to sensitive...

5CVSS6.4AI score0.009EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2021/05/20 11:51 a.m.24 views

CVE-2021-27461

A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected webserver applications allow access to stored data that can be obtained by using specially crafted URLs...

7.6AI score0.01397EPSS
SaveExploits0References1
Rows per page