560 matches found
CVE-2016-0871
Eaton Lighting EG2 Web Control 4.04P and earlier allows remote attackers to read the configuration file, and consequently discover credentials, via a direct request...
Code injection
Eaton Lighting EG2 Web Control 4.04P and earlier allows remote attackers to have an unspecified impact via a modified cookie...
Design/Logic Flaw
Eaton Lighting EG2 Web Control 4.04P and earlier allows remote attackers to read the configuration file, and consequently discover credentials, via a direct request...
CVE-2016-0871
The CVE-2016-0871 issue affects Eaton Lighting EG2 Web Control (V4.04P and prior). Root causes include CWE-565: Reliance on Cookies without Validation, and CWE-312: Cleartext Storage of Sensitive Information. A remote attacker could read configuration files and view credentials via a direct reque...
CVE-2016-2272
CVE-2016-2272 affects Eaton Lighting EG2 Web Control versions 4.04P and earlier. The ICS advisory notes an authentication bypass/root cause: reliance on cookies without proper validation/integrity, enabling a remote attacker to alter browser cookies and perform administrative actions that could c...
CVE-2016-2272
Eaton Lighting EG2 Web Control 4.04P and earlier allows remote attackers to have an unspecified impact via a modified cookie...
Eaton Lighting Systems EG2 Web Control Authentication Bypass Vulnerability (CNVD-2016-02006)
The Eaton Lighting Systems EG2 Web Control is a controller product from Eaton Lighting Systems USA for Internet and Wi-Fi LAN connections to the iLumin network. An authentication bypass vulnerability exists in Eaton Lighting Systems EG2 Web Control version 4.04P and earlier. A remote attacker cou...
Eaton Lighting Systems EG2 Web Control Authentication Bypass Vulnerability
The Eaton Lighting Systems EG2 Web Control is a controller product from Eaton Lighting Systems USA for Internet and Wi-Fi LAN connections to the iLumin network. An authentication bypass vulnerability exists in Eaton Lighting Systems EG2 Web Control V4.04P and prior versions. A remote attacker cou...
Eaton ELCSoft Programming Software Memory Vulnerabilities
OVERVIEW Ariele Calgaviano working with Zero Day Initiative has identified a heap-based memory corruption vulnerability and a stack buffer overflow vulnerability in Eaton’s ELCSoft programming software. Eaton has released a revision to mitigate these vulnerabilities. These vulnerabilities could b...
CVE-2015-6471
Eaton Cooper Power Systems ProView 4.x and 5.x before 5.1 on Form 6 controls and Idea and IdeaPLUS relays does not properly initialize padding fields in Ethernet packets, which allows remote attackers to obtain sensitive information by reading packet data...
Information disclosure
Eaton Cooper Power Systems ProView 4.x and 5.x before 5.1 on Form 6 controls and Idea and IdeaPLUS relays does not properly initialize padding fields in Ethernet packets, which allows remote attackers to obtain sensitive information by reading packet data...
CVE-2015-6471
CVE-2015-6471 affects Eaton Cooper Power Systems ProView 4.x and 5.x (before 5.1) on Form 6 controls and Idea/IdeaPLUS relays. The root cause is improper initialization of padding fields in Ethernet frames, allowing a remote attacker to read packet data and disclose information. Impact is informa...
Eaton Form 6 control和Idea/IdeaPLUS信息泄露漏洞
No description provided by source...
Eaton Form 6 control and Idea/IdeaPLUS information disclosure vulnerabilities
Eaton Form 6 control and Idea/IdeaPLUS are both products of the American company Eaton. The former is a controller product that provides instant access to operations and quickly determines the status of equipment as well as finding equipment faults, while the latter is a set of relay protection...
Eaton's Cooper Devices Improper Ethernet Frame Padding Vulnerability
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on October 22, 2015, and is being released to the ICS-CERT web site. David Formby and Raheem Beyah of Georgia Tech have identified a vulnerability caused by an Institute of Electrical and Electronics Engineers IEEE...
CVE-2014-9196
Eaton Cooper Power Systems ProView 4.0 and 5.0 before 5.0 11 on Form 6 controls and Idea and IdeaPLUS relays generates TCP initial sequence number ISN values linearly, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value...
Code injection
Eaton Cooper Power Systems ProView 4.0 and 5.0 before 5.0 11 on Form 6 controls and Idea and IdeaPLUS relays generates TCP initial sequence number ISN values linearly, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value...
CVE-2014-9196
The CVE covers Eaton Cooper Power Systems ProView Form 6 control and Idea/IdeaPLUS relays with Ethernet, affected since ProView 4.0–5.0. The root cause is a predictable, linearly generated TCP initial sequence number (ISN), enabling remote attackers to spoof sessions and mount MitM attacks. ICS-C...
CVE-2014-9196 Eaton’s Cooper Power Series Form 6 Control and Idea/IdeaPlus Relays with Ethernet
Eaton Cooper Power Systems ProView 4.0 and 5.0 before 5.0 11 on Form 6 controls and Idea and IdeaPLUS relays generates TCP initial sequence number ISN values linearly, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value...
Eaton Network Shutdown Module <= 3.21 - Remote PHP Code Injection
No description provided by source. !/usr/bin/env python Quick 'n' Dirty - Metasploit module didn't do it for me 2013 - Filip Waeytens - http://www.wsec.be Usage Example: $ python eaton.py 192.168.1.9 net user User accounts for \...