Lucene search
+L

1415 matches found

EUVD
EUVD
added 2026/08/24 5:07 p.m.7 views

EUVD-2026-64989

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setTime function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute...

8.6CVSS6.2AI score
SaveExploits0References2
CVE
CVE
added 2026/08/24 5:07 p.m.11 views

CVE-2026-71929

Multiple DrayTek VigorSwitch models contain an OS command injection vulnerability in the setDevProto function, caused by insufficient filtering of the username and password fields before command execution. A remote attacker with valid administrative credentials for the device's web management int...

8.6CVSS6.1AI score
SaveExploits0References2
CVE
CVE
added 2026/08/24 5:07 p.m.11 views

CVE-2026-71930

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setTime function, caused by insufficient filtering of username and password fields before command execution. A remote attacker with valid administrative credentials on the device's web management interface can cr...

8.6CVSS6.1AI score
SaveExploits0References2
Cvelist
Cvelist
added 2026/08/24 5:07 p.m.26 views

CVE-2026-71929 DrayTek VigorSwitch Multiple Models OS Command Injection via setDevProto

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevProto function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to...

8.6CVSS
SaveExploits0References2
EUVD
EUVD
added 2026/08/24 5:07 p.m.10 views

EUVD-2026-64988

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevProto function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to...

8.6CVSS6.2AI score
SaveExploits0References2
Cvelist
Cvelist
added 2026/08/24 5:07 p.m.24 views

CVE-2026-71930 DrayTek VigorSwitch Multiple Models OS Command Injection via setTime

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setTime function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute...

8.6CVSS
SaveExploits0References2
CVE
CVE
added 2026/08/24 5:07 p.m.10 views

CVE-2026-71928

Multiple DrayTek VigorSwitch models are affected by an OS command injection vulnerability in the fdftDevice function, caused by insufficient filtering of the username and password fields before command execution. A remote attacker with valid administrative credentials for the device's web managem...

8.6CVSS6.1AI score
SaveExploits0References2
EUVD
EUVD
added 2026/08/24 5:07 p.m.8 views

EUVD-2026-64987

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the fdftDevice function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execu...

8.6CVSS6.2AI score
SaveExploits0References2
CVE
CVE
added 2026/08/24 5:07 p.m.13 views

CVE-2026-71927

Multiple DrayTek VigorSwitch models are affected by a command injection vulnerability in the rebDevice function . The root cause is insufficient filtering of the username and password fields before they are passed to a system command execution context. A remote attacker with valid administrative ...

8.6CVSS6.1AI score
SaveExploits0References2
CVE
CVE
added 2026/08/24 5:07 p.m.13 views

CVE-2026-71926

Multiple DrayTek VigorSwitch models are affected by a command injection vulnerability in the setDevice function. The root cause is insufficient sanitization of the username, password, and location fields before command execution, allowing a remote attacker to run arbitrary commands with root priv...

8.6CVSS6.1AI score
SaveExploits0References2
EUVD
EUVD
added 2026/08/24 5:07 p.m.9 views

EUVD-2026-64986

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the rebDevice function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execut...

8.6CVSS6.2AI score
SaveExploits0References2
EUVD
EUVD
added 2026/08/24 5:07 p.m.7 views

EUVD-2026-64985

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevice function. The vulnerability is caused by insufficient sanitization of the username, password, and location fields before command execution. A remote attacker can trigger this vulnerability via crafted...

8.6CVSS6.2AI score
SaveExploits0References2
Cvelist
Cvelist
added 2026/08/24 5:07 p.m.25 views

CVE-2026-71927 DrayTek VigorSwitch Multiple Models OS Command Injection via rebDevice

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the rebDevice function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execut...

8.6CVSS
SaveExploits0References2
Cvelist
Cvelist
added 2026/08/24 5:07 p.m.23 views

CVE-2026-71925 DrayTek VigorSwitch Multiple Models OS Command Injection via getDetail

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execut...

8.6CVSS
SaveExploits0References2
CVE
CVE
added 2026/08/24 5:07 p.m.11 views

CVE-2026-71925

Multiple DrayTek VigorSwitch models are affected by an OS command injection vulnerability in the getDetail function . The root cause is insufficient filtering of the username and password fields before they are passed to command execution. A remote attacker with valid administrative credentials f...

8.6CVSS6.1AI score
SaveExploits0References2
EUVD
EUVD
added 2026/08/24 5:07 p.m.7 views

EUVD-2026-64984

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execut...

8.6CVSS6.2AI score
SaveExploits0References2
EUVD
EUVD
added 2026/08/24 5:07 p.m.11 views

EUVD-2026-64982

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the authset function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute...

8.6CVSS6.2AI score
SaveExploits0References2
CVE
CVE
added 2026/08/24 5:07 p.m.11 views

CVE-2026-71924

Multiple DrayTek VigorSwitch models are affected by an OS command injection vulnerability in the getVid function, caused by insufficient filtering of the username and password fields before command execution. A remote attacker with valid administrative credentials to the device's web management i...

8.6CVSS6.1AI score
SaveExploits0References2
CVE
CVE
added 2026/08/24 5:07 p.m.11 views

CVE-2026-71923

Multiple DrayTek VigorSwitch models are affected by a command injection vulnerability in the auth_set function. The root cause is insufficient filtering of the username and password fields before they are passed to command execution. A remote attacker with valid administrative credentials for the...

8.6CVSS6.1AI score
SaveExploits0References2
Cvelist
Cvelist
added 2026/08/24 5:07 p.m.25 views

CVE-2026-71924 DrayTek VigorSwitch Multiple Models OS Command Injection via getVid

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getVid function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute...

8.6CVSS
SaveExploits0References2
Rows per page
Query Builder