added yesterday5 views

EUVD-2022-55996

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS5.8AI score0.00045EPSS
Exploits0References3
NVD
NVD
added 2 days ago6 views

CVE-2022-4992

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS0.00045EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 2 days ago5 views

CVE-2022-4992

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...

8.8CVSS5.8AI score0.00045EPSS
Exploits0References3
Cvelist
Cvelist
added 2 days ago24 views

CVE-2019-25721 Dräger Infinity M300 VG2.3.1 Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS0.00016EPSS
Exploits0References2
EUVD
EUVD
added 2 days ago3 views

EUVD-2019-20157

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS5.8AI score0.00016EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 2 days ago3 views

CVE-2019-25721 Dräger Infinity M300 VG2.3.1 Network-Based Denial of Service

Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...

7.1CVSS5.8AI score0.00016EPSS
Exploits0References2
EUVD
EUVD
added 2 days ago3 views

EUVD-2019-20156

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00017EPSS
Exploits0References2
ATTACKERKB
ATTACKERKB
added 2 days ago4 views

CVE-2019-25719

Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...

8.8CVSS5.8AI score0.00017EPSS
Exploits0References4
EUVD
EUVD
added 2 days ago1 views

EUVD-2019-20155

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS5.8AI score0.00012EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 2 days ago4 views

CVE-2019-25717 Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS5.8AI score0.00012EPSS
Exploits0References2
Cvelist
Cvelist
added 2 days ago29 views

CVE-2019-25717 Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS0.00012EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 3 days ago6 views

CVE-2019-25718 Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass

Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause...

8.6CVSS5.8AI score0.00013EPSS
Exploits0References1
Cvelist
Cvelist
added 3 days ago24 views

CVE-2019-25716 Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...

7.1CVSS0.00046EPSS
Exploits0References2
Prion
Prion
added 2019/01/28 10:29 p.m.13 views

Design/Logic Flaw

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about internals of the...

3.3CVSS6.8AI score0.00187EPSS
Exploits0References2
Prion
Prion
added 2019/01/28 10:29 p.m.13 views

Default configuration

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient...

3.3CVSS6.5AI score0.00179EPSS
Exploits0References2
Cvelist
Cvelist
added 2019/01/28 10:0 p.m.11 views

CVE-2018-19010

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient...

6.4AI score0.00179EPSS
Exploits0References2
Prion
Prion
added 2019/01/28 9:29 p.m.12 views

Design/Logic Flaw

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker ...

7.2CVSS7.6AI score0.00067EPSS
Exploits0References2
NVD
NVD
added 2019/01/28 9:29 p.m.8 views

CVE-2018-19012

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker ...

7.8CVSS7.7AI score0.00067EPSS
Exploits0References2
Cvelist
Cvelist
added 2019/01/28 9:0 p.m.10 views

CVE-2018-19012

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker ...

7.7AI score0.00067EPSS
Exploits0References2
CVE
CVE
added 2019/01/28 9:0 p.m.42 views

CVE-2018-19012

The CVE-2018-19012 issue affects Dräger Infinity Delta, Delta XL, Kappa, and Infinity Explorer C700 (all versions). The root cause is improper privilege management in a dialog that allows breaking out of kiosk mode, enabling an attacker to reach the underlying OS and take control of the system. T...

7.8CVSS7.6AI score0.00067EPSS
Exploits0References2Affected Software1