68 matches found
Design/Logic Flaw
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection', reflective DLL, vulnerability exists in EcoStruxure Control Expert all versions prior to 14.1 Hot Fix, Unity Pro all versions, Modicon M340 all versions prior to V3.20, Modicon M580 all...
Command injection
Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system...
CVE-2019-7670
Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system...
PYSEC-2019-17
In Django 1.11.x before 1.11.18, 2.0.x before 2.0.10, and 2.1.x before 2.1.5, an Improper Neutralization of Special Elements in Output Used by a Downstream Component issue exists in django.views.defaults.pagenotfound, leading to content spoofing in a 404 error page if a user fails to recognize th...
PYSEC-2019-87
In Django 1.11.x before 1.11.18, 2.0.x before 2.0.10, and 2.1.x before 2.1.5, an Improper Neutralization of Special Elements in Output Used by a Downstream Component issue exists in django.views.defaults.pagenotfound, leading to content spoofing in a 404 error page if a user fails to recognize th...
CVE-2019-3498: Improper Neutralization of Special Elements in Output Used by a Downstream Component
In Django 1.11.x before 1.11.18, 2.0.x before 2.0.10, and 2.1.x before 2.1.5, an Improper Neutralization of Special Elements in Output Used by a Downstream Component issue exists in django.views.defaults.pagenotfound, leading to content spoofing in a 404 error page if a user fails to recognize th...
CVE-2018-1000854
esigate.org esigate version 5.2 and earlier contains a CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection' vulnerability in ESI directive with user specified XSLT that can result in Remote Code Execution. This attack appear to be exploitable vi...
CVE-2017-5799: Improper Neutralization of Special Elements in Output Used by a Downstream Component
A Remote Code Execution vulnerability in HPE OpenCall Media Platform OCMP was found. The vulnerability impacts OCMP versions prior to 3.4.2 RP201 for OCMP 3.x, all versions prior to 4.4.7 RP702 for OCMP 4.x...