46 matches found
[SECURITY] Fedora 38 Update: libindi-2.0.0-3.fc38
INDI is a distributed control protocol designed to operate astronomical instrumentation. INDI is small, flexible, easy to parse, and scalable. It supports common DCS functions such as remote control, data acquisition, monitoring, and a lot more...
Emerson DeltaV Distributed Control System Insufficient Verification of Data Authenticity (CVE-2022-30260)
Emerson DeltaV Distributed Control System DCS has insufficient verification of firmware integrity an inadequate checksum approach, and no signature. This affects versions before 14.3 of DeltaV M-series, DeltaV S-series, DeltaV P-series, DeltaV SIS, and DeltaV CIOC/EIOC/WIOC IO cards. This plugin...
CVE-2022-30317
Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access CDA EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell...
Authentication flaw
Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access CDA EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell...
Emerson DeltaV Distributed Control System Use of Hard-Coded Credentials (CVE-2022-29962)
The Emerson DeltaV Distributed Control System DCS controllers and IO cards through 2022-04-29 misuse passwords. FTP has hardcoded credentials but may often be disabled in production. This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350. - The Emerson...
Emerson DeltaV Distributed Control System Use of Hard-Coded Credentials (CVE-2022-29964)
The Emerson DeltaV Distributed Control System DCS controllers and IO cards through 2022-04-29 misuse passwords. WIOC SSH provides access to a shell as root, DeltaV, or backup via hardcoded credentials. NOTE: this is different from CVE-2014-2350. - The Emerson DeltaV Distributed Control System DCS...
CVE-2022-29963
The Emerson DeltaV Distributed Control System DCS controllers and IO cards through 2022-04-29 misuse passwords. TELNET on port 18550 provides access to a root shell via hardcoded credentials. This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350...
CVE-2022-29964
The Emerson DeltaV Distributed Control System DCS controllers and IO cards through 2022-04-29 misuse passwords. WIOC SSH provides access to a shell as root, DeltaV, or backup via hardcoded credentials. NOTE: this is different from CVE-2014-2350...
CVE-2022-29957
The Emerson DeltaV Distributed Control System DCS through 2022-04-29 mishandles authentication. It utilizes several proprietary protocols for a wide variety of functionality. These protocols include Firmware upgrade 18508/TCP, 18518/TCP; Plug-and-Play 18510/UDP; Hawk services 18507/UDP; Managemen...
Emerson DeltaV Distributed Control System 信任管理问题漏洞
Emerson DeltaV Distributed Control System is an automated distributed control system from Emerson. The system includes features such as network security management, alarm management, batch control, and change management. The Emerson DeltaV Distributed Control System is vulnerable to a trust...
Emerson DeltaV Distributed Control System
1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable on adjacent network/high attack complexity Vendor: Emerson Equipment: DeltaV Distributed Control System Vulnerabilities: Missing Authentication for Critical Function, Use of Hard-coded Credentials, Insufficient Verification of Data...
PT-2022-3160 · Emerson · Emerson Deltav Distributed Control System
Name of the Vulnerable Software and Affected Versions: Emerson DeltaV Distributed Control System DCS controllers and IO cards through 2022-04-29 Description: The issue is related to the misuse of passwords and the use of hardcoded credentials in the TELNET service on port 18550, which provides...
Emerson DeltaV Distributed Control System Use of Hard-Coded Credentials (CVE-2022-29962, CVE-2022-29963, CVE-2022-29964, CVE-2022-29965, CVE-2022-30261, CVE-2022-30263, CVE-2022-30266)
The device may be vulnerable to flaws related to OT:ICEFALL. These vulnerabilities identify the insecure-by-design nature of OT devices and may not have a clear remediation path. As such, Nessus is unable to test specifically for these vulnerabilities but has identified the device to be one that...
CISA Releases Security Advisories Related to OT:ICEFALL (Insecure by Design) Report
CISA is aware that Forescout researchers have released OT:ICEFALL, a report on 56 vulnerabilities caused by insecure-by-design practices in operational technology across multiple vendors. The vulnerabilities are divided into four main categories: insecure engineering protocols, weak cryptography ...
Siemens TIA Administrator Denial of Service Vulnerability
SIMATIC PCS neo is a distributed control system DCS.TIA Administrator is a web-based framework.Siemens Network Planner SINETPLAN supports you as a planner of PROFINET-based automation systems.TIA Portal is a PC A denial of service vulnerability exists in Siemens TIA Administrator, which can be...
FritzFrog: P2P Botnet Hops Back on the Scene
FritzFrog is a peer-to-peer botnet, which means its command and control server is not limited to a single, centralized machine, but rather can be done from every machine in its distributed network. In other words, every host running the malware process becomes part of the network, and is capable ...
The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, allows a perpetrator to write arbitrary files.
The vulnerability of the centralized system for managing emergency messages and events in CAMS for HIS distributed control systems CENTUM VP and CENTUM VP Entry Class, along with the OPC-server Exaopc, is related to errors in processing the relative path to the catalog. Exploiting this...
Emerson Electric Emerson DeltaV Distributed Control System 访问控制错误漏洞
Emerson Electric Emerson DeltaV Distributed Control System is an automated distributed control system from Emerson Electric. The system includes features such as network security management, alarm management, batch control, and change management. An access control error vulnerability exists in...
The vulnerability of distributed control systems like CENTUM, related to access control errors, allows attackers to gain unauthorized access to protected information.
The vulnerability of distributed control systems like CENTUM is related to access control errors. Exploiting this vulnerability can allow an attacker to gain unauthorized access to protected information...
Denial of Service Vulnerability in Honeywell DCS C300 Controller (CNVD-2020-67880)
The CC-PCNT02 is a controller for Honeywell DCS C300 systems that supports Ethernet communication. A denial of service vulnerability exists in the Honeywell DCS C300 controller that can be exploited by an attacker to cause a denial of service...