•added 2026/11/03 9:17 a.m.•5 views

CVE-2026-105981

Improper input validation in the Digital I/O function may allow a remote attacker with high privileges to inject operating system commands and execute them with root privileges...

8.6CVSS0.00358EPSS
SaveExploits0References1
NVD
NVD
•added 2026/11/03 9:17 a.m.•6 views

CVE-2026-109161

Insufficient bounds checking in the Digital I/O function may allow a remote attacker with high privileges to cause a denial of service...

6.9CVSS0.003EPSS
SaveExploits0References1
CVE
CVE
•added 2026/11/03 9:00 a.m.•7 views

CVE-2026-109161

The Welotec system is affected by a buffer overflow vulnerability (CWE-120) caused by insufficient bounds checking within the Digital I/O function . A remote attacker with high privileges could exploit this flaw to cause a denial of service (DoS). While the CVSS 4.0 score reflects a Medium severi...

6.9CVSS5.9AI score0.003EPSS
SaveExploits0References1
EUVD
EUVD
•added 2026/11/03 9:00 a.m.•7 views

EUVD-2026-115705

Insufficient bounds checking in the Digital I/O function may allow a remote attacker with high privileges to cause a denial of service...

6.9CVSS5.9AI score0.003EPSS
SaveExploits0References1
CVE
CVE
•added 2026/11/03 8:59 a.m.•7 views

CVE-2026-105981

CVE-2026-105981 identifies a command injection vulnerability in Welotec software. The root cause is improper input validation within the Digital I/O function , which could allow a remote attacker with high privileges to inject and execute operating system commands with root privileges . While the...

8.6CVSS6.2AI score0.00358EPSS
SaveExploits0References1
EUVD
EUVD
•added 2026/11/03 8:59 a.m.•5 views

EUVD-2026-115707

Improper input validation in the Digital I/O function may allow a remote attacker with high privileges to inject operating system commands and execute them with root privileges...

8.6CVSS6.2AI score0.00358EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2019/07/05 12:00 a.m.•19 views

Siemens SIMATIC ET 200eco PN 8 outputs /double assignment Digital I/O module

Binary data 764636.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/07/05 12:00 a.m.•23 views

Siemens SIMATIC ET 200eco PN 8 outputs Digital I/O module

Binary data 764640.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/07/05 12:00 a.m.•23 views

Siemens SIMATIC ET 200eco PN 16 outputs /double assignment Digital I/O module

Binary data 764639.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/07/05 12:00 a.m.•21 views

Siemens SIMATIC ET 200eco PN 8 inputs /double assignment Digital I/O module

Binary data 764633.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/07/05 12:00 a.m.•25 views

Siemens SIMATIC ET 200eco PN 8 outputs /double assignment Digital I/O module

Binary data 764637.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/07/05 12:00 a.m.•21 views

Siemens SIMATIC ET 200eco PN 8 inputs /single assignment Digital I/O module

Binary data 764634.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/07/05 12:00 a.m.•20 views

Siemens SIMATIC ET 200eco PN 8 outputs /double assignment Digital I/O module

Binary data 764638.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•13 views

Honeywell 2MLI-D28B Digital I/O Module Detection

Binary data 750854.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•14 views

Yokogawa SDV53A Safety Digital I/O Module Detection

Binary data 758895.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•24 views

Honeywell 2MLF-AC8A-CC Digital I/O Module Detection

Binary data 750811.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•11 views

ABB 1SAP231900R0000 DC562 S500 I O Digital I/O Module Detection

Binary data 756412.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•18 views

Acromag ES2117 General Purpose Digital I/O Detection

Binary data 762540.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•14 views

Beckhoff Multi-touch built-in Panel PC General Purpose Digital I/O Detection

Binary data 762644.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/05/08 12:00 a.m.•13 views

Yokogawa S2MD Safety Digital I/O Module Detection