Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56781)
powerpc/prominit: missing powermac size-cells. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504722; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-44949)
parisc: fix a possible DMA corruption ARCHDMAMINALIGN was defined as 16 - this is too small - it may be possible that two unrelated 16-byte allocations share a cache line. If one of these allocations is written using DMA and the other is written using cached write, the value that was written with...
Siemens SCALANCE and RUGGEDCOM Devices NULL Pointer Dereference (CVE-2024-50198)
iio: light: veml6030: fix IIO device retrieval from embedded device. The dev pointer that is received as an argument in the inilluminanceperiodavailableshow function references the device embedded in the IIO device, not in the i2c client. devtoiiodev must be used to accessthe right data. The...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49966)
ocfs2: cancel dqisyncwork before freeing oinfo ocfs2globalreadinfo will initialize and schedule dqisyncwork at the end. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; i...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56586)
f2fs: fix f2fsbugon when uninstalling filesystem call f2fsevictinode. creating a large files during checkpoint disable until it runs out of space and then delete it, then remount to enable checkpoint again, and then unmount the filesystem triggers the f2fsbugon. This plugin only works with...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56596)
jfs: array-index-out-of-bounds in jfsreaddir. The stbl might contain some invalid values. Added a check to return error code in that case. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...
Siemens SCALANCE and RUGGEDCOM Devices NULL Pointer Dereference (CVE-2024-46677)
gtp: fix NULL pointer dereference. When sockfdlookup fails, gtpencapenablesocket returns a NULL pointer, but its callers only check for error pointers thus miss the NULL pointer case. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-49985)
i2c: stm32f7: In case there is any sort of clock controller attached to the I2C bus controller, for example Versaclock or even an AIC32x4 I2C codec, then an I2C transfer triggered from the clock controller clkops .prepare callback may trigger a deadlock on drivers/clk/clk.c preparelock mutex. Thi...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-53172)
ubi: fastmap: The duplicate slab cache names can be detected and a kernel WARNING is thrown out. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...
Siemens SCALANCE and RUGGEDCOM Devices Missing Release of Memory after Effective Lifetime (CVE-2024-44971)
net: dsa: bcmsf2: vulnerability caused a memory leak by not decrementing the reference count after finding and removing PHY devices, which has been fixed by adding a call to phydevicefree to balance the reference count. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-56645)
can: j1939: vulnerability involves a reference count underflow issue in j1939sessionnew, which is fixed by adding an extra skbget to match the behavior of j1939sessionskbqueue. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-40929)
wifi: iwlwifi: mvm: check nssids before accessing the ssids.In some versions of cfg80211, the ssids poinet might be a valid one even though nssids is 0. Accessing the pointer in this case will cuase an out-of-bound access. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-42247)
wireguard: allowedips: unaligned 64-bit memory accesses. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504555; scriptversion"1.2";...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-40947)
ima: Avoid blocking in RCU read-side critical section, a panic happens in imamatchpolicy. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504587;...
CVE-2025-63258
A remote command execution RCE vulnerability was discovered in all H3C ERG3/ERG5 series routers and XiaoBei series routers, cloud gateways, and wireless access points versions R0162P07, UAP700-WPT330-E2265, UAP672-WPT330-R2262, UAP662E-WPT330-R2262P03, WAP611-WPT330-R1348-OASIS,...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-46758)
hwmon: lm95234 underflows seen when writing limit attributes DIVROUNDCLOSEST after kstrtol results in an underflow if a large negative number such as -9223372036854775808 is provided by the user. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50181)
clk: imx: Remove CLKSETPARENTGATE for DRAM mux for i.MX7D. For i.MX7D DRAM related mux clock, the clock source change should ONLY be done done in low level asm code without accessing DRAM, and then calling clk API to sync the HW clock status with clk tree, it should never touch real clock source...
Siemens SCALANCE and RUGGEDCOM Devices NULL Pointer Dereference (CVE-2024-47756)
PCI: keystone: Fix if-statement expression in kspciequirk. This code accidentally uses && where || was intended. It potentially results in a NULL dereference. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-50290)
media: cx24116: prevent overflows on SNR calculus as reported by Coverity, if reading SNR registers fail, a negative number will be returned, causing an underflow when reading SNR registers. Prevent that. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE and RUGGEDCOM Devices Improper Input Validation (CVE-2024-41034)
nilfs2: kernel bug on rename operation of broken directory. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504476; scriptversion"1.2";...