Lucene search
+L

330 matches found

NVD
NVD
•added 2022/03/18 9:15 p.m.•22 views

CVE-2022-25428

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function...

10CVSS0.01692EPSS
SaveExploits1References1
attackerkb
attackerkb
•added 2022/03/18 9:15 p.m.•7 views

CVE-2022-25428

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function...

10CVSS7.2AI score0.01692EPSS
SaveExploits1References2
Prion
Prion
•added 2022/03/18 9:15 p.m.•33 views

Stack overflow

Tenda AC6 v15.03.05.09multi was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function...

10CVSS9.6AI score0.01692EPSS
SaveExploits1References1Affected Software1
Cvelist
Cvelist
•added 2022/03/18 8:53 p.m.•47 views

CVE-2022-25449

Tenda AC6 v15.03.05.09multi was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function...

9.9AI score0.01692EPSS
SaveExploits1References1
CVE
CVE
•added 2022/03/18 8:53 p.m.•108 views

CVE-2022-25449

CVE-2022-25449 affects Tenda AC6 (v15.03.05.09_multi). A stack overflow is triggered by the deviceId parameter in the saveParentControlInfo function, enabling arbitrary code execution according to CNVD/CNNVD/Red Hat and NVD entries. The vulnerability is documented across multiple sources as a mem...

10CVSS9.6AI score0.01692EPSS
SaveExploits1References1Affected Software1
Cvelist
Cvelist
•added 2022/03/18 8:53 p.m.•38 views

CVE-2022-25428

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function...

9.9AI score0.01692EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/03/18 12:00 a.m.•3 views

CVE-2022-25449: Out-of-bounds Write

Tenda AC6 v15.03.05.09multi was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function...

10CVSS8.4AI score0.01692EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/03/18 12:00 a.m.•3 views

CVE-2022-25428: Out-of-bounds Write

Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function...

10CVSS8.4AI score0.01692EPSS
SaveExploits1References2
CNNVD
CNNVD
•added 2022/03/18 12:00 a.m.•13 views

Tenda AC6 缓冲区错误漏洞

Tenda AC6 is a wireless router from Tenda, China. Tenda AC6 is vulnerable to a buffer overflow vulnerability, which stems from the deviceId parameter in the saveParentControlInfo function that does not properly validate data boundaries when performing operations on memory, and can be exploited by...

10CVSS6.3AI score0.01692EPSS
SaveExploits1References3
CNVD
CNVD
•added 2022/03/14 12:00 a.m.•27 views

Tenda AX1806 saveParentControlInfo function stack overflow vulnerability

The Tenda AX1806 is a WiFi6 wireless router from Tenda, a Chinese company. A stack overflow vulnerability exists in the Tenda AX1806 saveParentControlInfo function, which can be exploited by an attacker to cause a Denial of Service DoS via the deviceId parameter...

7.8CVSS7AI score0.01238EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/03/09 12:00 a.m.•5 views

CVE-2022-25554: Out-of-bounds Write

Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service DoS via the deviceId parameter...

7.8CVSS7.4AI score0.01238EPSS
SaveExploits1References2
VulnCheck KEV
VulnCheck KEV
•added 2021/04/12 12:00 a.m.•11 views

VulnCheck KEV: CVE-2013-7389

Multiple cross-site scripting XSS vulnerabilities in D-Link DIR-645 Router Rev. A1 with firmware before 1.04B11 allow remote attackers to inject arbitrary web script or HTML via the 1 deviceid parameter to parentalcontrols/bind.php, 2 RESULT parameter to info.php, or 3 receiver parameter to...

4.3CVSS5.9AI score0.27753EPSS
SaveIn wildExploits4References2
Tenable Nessus
Tenable Nessus
•added 2020/06/26 12:00 a.m.•38 views

Fedora 31 : fwupd (2020-ad1c74c2a1)

New upstream release - Actually reload the DFU device after upgrade has completed - Capture the dock SKU in report metadata - Correctly set the Logitech device protocol - Do not use shim for non-secure boot configurations - Ensure that the DeviceID is set for child devices - Fix an error when...

6CVSS5.9AI score0.0049EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
•added 2020/05/22 12:00 a.m.•17 views

PT-2020-13516 · Tenda · Tenda Ac6 +3

Name of the Vulnerable Software and Affected Versions: Tenda AC6 version 1.0 V15.03.05.19 multi TD01 Tenda AC9 version 1.0 V15.03.05.196318 CN Tenda AC9 version 3.0 V15.03.06.42 multi Tenda AC15 version 1.0 V15.03.05.19 multi TD01 Tenda AC18 version 15.03.05.196318 CN Description: A buffer overfl...

9.8CVSS7.8AI score0.03203EPSS
SaveExploits1References6
OSV
OSV
•added 2019/06/05 6:29 p.m.•12 views

CVE-2019-12196

A SQL injection vulnerability in /client/api/json/v2/nfareports/compareReport in Zoho ManageEngine NetFlow Analyzer 12.3 allows attackers to execute arbitrary SQL commands via the DeviceID parameter...

9.8CVSS7.6AI score0.69071EPSS
SaveExploits0References2
NVD
NVD
•added 2019/06/05 6:29 p.m.•31 views

CVE-2019-12196

A SQL injection vulnerability in /client/api/json/v2/nfareports/compareReport in Zoho ManageEngine NetFlow Analyzer 12.3 allows attackers to execute arbitrary SQL commands via the DeviceID parameter...

9.8CVSS9.9AI score0.69071EPSS
SaveExploits0References2
Prion
Prion
•added 2019/06/05 6:29 p.m.•20 views

Sql injection

A SQL injection vulnerability in /client/api/json/v2/nfareports/compareReport in Zoho ManageEngine NetFlow Analyzer 12.3 allows attackers to execute arbitrary SQL commands via the DeviceID parameter...

7.5CVSS9.8AI score0.69071EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/06/05 12:00 a.m.•3 views

CVE-2019-12196: Improper Neutralization of Special Elements used in an SQL Command

A SQL injection vulnerability in /client/api/json/v2/nfareports/compareReport in Zoho ManageEngine NetFlow Analyzer 12.3 allows attackers to execute arbitrary SQL commands via the DeviceID parameter...

9.8CVSS6.3AI score0.69071EPSS
SaveExploits0References2
CNVD
CNVD
•added 2018/03/07 12:00 a.m.•16 views

D-Link DIR Series Cross-Site Scripting Vulnerability (CNVD-2018-06630)

The D-Link DIR-868L, DIR-865L and DIR-860L are all wireless router products from AUO D-Link. A cross-site scripting vulnerability exists in the htdocs/webinc/js/advparentctrlmap.php file in the D-Link DIR-868L, DIR-865L, and DIR-860L. A remote attacker can exploit the vulnerability by sending a...

6.1CVSS6.3AI score0.01624EPSS
SaveExploits1References1
NVD
NVD
•added 2018/03/06 8:29 p.m.•25 views

CVE-2018-6527

XSS vulnerability in htdocs/webinc/js/advparentctrlmap.php in D-Link DIR-868L DIR868LA1FW112b04 and previous versions, DIR-865L DIR-865LREVAFIRMWAREPATCH1.08.B01 and previous versions, and DIR-860L DIR860LA1FW110b04 and previous versions allows remote attackers to read a cookie via a crafted...

6.1CVSS5.9AI score0.01624EPSS
SaveExploits1References4
Rows per page
Query Builder