55323 matches found
CVE-2026-34123 Whitelist Validation Bypass in TP-Link Tapo C520WS
On Tapo C520WS v2, restricted accounts for example, hub users are intended to execute only a limited set of low‑sensitivity operations. Due to a logic flaw in the device’s API authorization mechanism, an attacker can craft requests that leverage legitimate “method mapping” behavior to bypass...
CVE-2026-34123
On Tapo C520WS v2, restricted accounts for example, hub users are intended to execute only a limited set of low‑sensitivity operations. Due to a logic flaw in the device’s API authorization mechanism, an attacker can craft requests that leverage legitimate “method mapping” behavior to bypass...
MINI-X8Q5-8M3X-3W5J
Bulletin has no description...
MINI-2RPH-826P-6PM8
Bulletin has no description...
MINI-JGP4-R72P-C688
Bulletin has no description...
UPnPHostFileRead
Description Local arbitrary file read PoC exploit for the Wind...
CVE-2025-27852
The locally served web site on the Garmin WDU v1 1.4.6 and v2 5.0 allows a reflected cross site scripting XSS attack. This allows an attacker on the local network segment to execute arbitrary JavaScript code within the context of the WDU webpage. Full administrator level access to the device is...
CVE-2026-7720
A weakness has been identified in Totolink WA300 5.2cu.7112B20190227. The impacted element is the function setLanguageCfg of the file /cgi-bin/cstecgi.cgi of the component POST Request Handler. This manipulation of the argument langType causes command injection. Remote exploitation of the attack ...
CVE-2026-10719
Out of bounds write in openSeaChest’s --showSupportedFormats in Seagate’s openSeaChest v25.05.3 on all supported platforms allows for writing 1 extra byte outside of allocated memory which sets a value to 1 via a maliciously crafted NVMe device with a bogus value in the namespace FLBAS byte...
CVE-2026-36178
The factory reset functionality in GNCC GP5 v7.1.76 fails to clear sensitive cryptographic material in the JFFS2 configuration partition, possibly allowing attackers to recover and obtain sensitive user data...
CVE-2026-31159
An issue was discovered in ToToLink A3300R firmware v17.0.0cu.557B20221024 allowing attackers to execute arbitrary commands via the password parameter to /cgi-bin/cstecgi.cgi...
CVE-2026-0096
In getAppLabel of ForgetDeviceDialogFragment.java, there is a possible trick the user into forgetting a device due to misleading or insufficient UI. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation...
CVE-2026-0070
In multiple functions of DevicePolicyManagerService.java, there is a possible way to hide a system critical package due to improper input validation. This could lead to local denial of service with no additional execution privileges needed. User interaction is not needed for exploitation...
CVE-2026-0097
In multiple locations, there is a possible way to bypass user interaction when pairing an LE device due to a logic error. This could lead to remote proximal/adjacent escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation...
CVE-2025-59601
Information Disclosure when resetting device to factory default settings through powerline interface allows unauthorized access to device configuration...
CVE-2025-4386
Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal....
CVE-2026-7824
An issue was discovered in the PaperCut Hive Ricoh embedded application. When the "Deep Logging" diagnostic mode is enabled, the application inadvertently records administrative credentials in plain text within the log files. An attacker with administrative access to the PaperCut Hive management...
CVE-2026-21007
Improper check for exceptional conditions in Device Care prior to SMR Apr-2026 Release 1 allows physical attackers to bypass Knox Guard...
CVE-2026-5944
An improper access control vulnerability exists in the Cisco Intersight Device Connector for Nutanix Prism Central. The service exposes an API passthrough endpoint on TCP port 7373 that is accessible within the network scope of the deployment environment without authentication. An unauthenticated...