818 matches found
EUVD-2026-48745
The web management interface of Tycon Systems TPDIN-Monitor-WEB2 does not perform server-side validation of credentials during the login process. By submitting empty values for both credential fields, an unauthenticated remote attacker can bypass the authentication check and establish a valid...
CVE-2026-55732
Out-of-bounds Read CWE-125 in BACnet packet parsing bacdtdatetimetotod in Loytec LIP-ME201C, L-INX, L-GATE, L-ROC, L-IOB, L-DALI, L-VIS and L-PAD through 8.4.18 on LINX-A64 allows an unauthenticated remote attacker to crash linxa64.exe and ultimately reboot the device via a malformed BACnet...
EUVD-2026-48597
Out-of-bounds Read CWE-125 in BACnet packet parsing bacdtdatetimetotod in Loytec LIP-ME201C, L-INX, L-GATE, L-ROC, L-IOB, L-DALI, L-VIS and L-PAD through 8.4.18 on LINX-A64 allows an unauthenticated remote attacker to crash linxa64.exe and ultimately reboot the device via a malformed BACnet...
PT-2026-64420
Name of the Vulnerable Software and Affected Versions Tycon Systems TPDIN-Monitor-WEB2 affected versions not specified Description The web management interface fails to perform server-side validation of credentials during the login process. An unauthenticated remote attacker can bypass the...
CVE-2026-22099
The charging station does not require authentication for Bluetooth commands to perform actions. The functionality exposed includes sensitive information leakage, triggering reboots, or pushing a firmware update URL...
TP-Link TL-WR841N Web interface stack buffer overflow vulnerability
The TP-Link TL-WR841N v14 is a wireless router produced by the Chinese company TP-Link. The TP-Link TL-WR841N v14 has a stack buffer overflow vulnerability in its web interface. This vulnerability arises from improper handling of specially crafted HTTP requests, leading to a buffer overflow...
CVE-2026-10825
A denial-of-service vulnerability exists in the WebSocket API due to insufficient validation and handling of JSON-based requests. A low-privileged authenticated attacker can send a specially crafted request that causes service disruption and may result in an unexpected device reboot...
EUVD-2026-37043
A denial-of-service vulnerability exists in the WebSocket API due to insufficient validation and handling of JSON-based requests. A low-privileged authenticated attacker can send a specially crafted request that causes service disruption and may result in an unexpected device reboot...
CVE-2026-10825 Improper JSON Input Validation in WebSocket API Leads to Denial of Service
A denial-of-service vulnerability exists in the WebSocket API due to insufficient validation and handling of JSON-based requests. A low-privileged authenticated attacker can send a specially crafted request that causes service disruption and may result in an unexpected device reboot...
CVE-2026-1871
TP-Link Tapo C200 v5 contains a stack-based buffer overflow flaw in RTSP authentication handling due to improper validation of Authorization header field lengths, which can be triggered by a crafted authentication request. Successful exploitation causes the affected RTSP core service process to...
CVE-2019-25720 Dräger SC Monitoring Devices DoS via Malformed Network Packet
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packet...
CVE-2022-4992
CVE-2022-4992 affects Dräger Infinity Acute Care System and Standalone Infinity M540, VG4.1.1, VG4.0.3 and lower (VG4.2 partially affected). The issue is a network message handling vulnerability that lets remote attackers inject spoofed/tampered data to cause denial-of-service, potentially modify...
CVE-2022-4992 Dräger Infinity M540 VG4.1.1 Spoofed Network Message Handling DoS/Tampering
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors versions VG4.1.1, VG4.0.3, and lower with VG4.2 partially affected contain a network message handling vulnerability that allows remote attackers to inject spoofed or tampered data and cause denial-of-service condition...
CVE-2019-25721
Dräger Infinity M300 patient worn monitors with software version VG2.3.1 and earlier contain a network-based denial of service vulnerability that allows network-adjacent attackers to repeatedly trigger device reboots by sending malicious requests over the Infinity Network. Attackers can exploit...
CVE-2019-25724 Dräger Infinity M300 VG2.x Network-Based Denial of Service
Dräger Infinity M300 patient worn monitors with software version VG2.x and earlier contain a network-based denial of service vulnerability that allows attackers with access to the hospital or Infinity Network to repeatedly trigger device reboots until the device enters a fail state requiring manu...
CVE-2019-25722
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...
CVE-2019-25722 Dräger SC Monitoring Devices Hard-coded Credentials and DoS
Dräger SC Monitoring devices SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL contain hard-coded plaintext credentials in source code and a denial-of-service vulnerability that allows local and remote attackers to compromise device integrity across all software versions. A local attacker with...
CVE-2019-25722
The CVE-2019-25722 entry concerns Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL). Affected component: source code contains hard-coded plaintext credentials that can be used by a local attacker to access service and clinical accounts; a remote attacker can send m...
CVE-2019-25719
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...
EUVD-2019-20156
Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attacke...