11 matches found
CVE-2026-129281
N-able N-central before 2026.4.1 HF3 checks only a view permission for ServerII2 operations that write device execution configuration. An authenticated user with view-only access to a device can set configuration that the Windows agent on that device acts on...
CVE-2026-129281
N-able N-central versions prior to 2026.4.1 HF3 are vulnerable to an incorrect authorization flaw in ServerII2 . The system fails to properly validate permissions for operations that write device execution configurations, incorrectly accepting only a view permission . This allows an authenticated...
EUVD-2026-126966
N-able N-central before 2026.4.1 HF3 checks only a view permission for ServerII2 operations that write device execution configuration. An authenticated user with view-only access to a device can set configuration that the Windows agent on that device acts on...
PT-2026-82075
Name of the Vulnerable Software and Affected Versions UniFi Enterprise Audio/Video Bridge affected versions not specified Description An improper input validation issue allows a network-based actor to perform command injection on the device. Command injection is a flaw where an attacker can execu...
Exploit for CVE-2026-13768
CVE-2026-13768: Privileged IoT Hub Credential — Fleet Enumerat...
CVE-2024-23938
Silicon Labs Gecko OS Debug Interface Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Silicon Labs Gecko OS. Authentication is not required to exploit this vulnerability. T...
CVE-2023-2003
Embedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device's data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device...
Schneider Electric Modicon M580 FTP incomplete firmware update denial-of-service vulnerability
Summary An exploitable denial-of-service vulnerability exists in the FTP firmware update function of the Schneider Electric Modicon M580 Programmable Automation Controller, firmware version SV2.80. A specially crafted set of FTP commands can cause the device to enter a recoverable fault state,...
Input validation
A vulnerability has been identified in SIMATIC STEP 7 TIA Portal and WinCC TIA Portal V10, V11, V12 All versions, SIMATIC STEP 7 TIA Portal and WinCC TIA Portal V13 All versions V13 SP2 Update 2, SIMATIC STEP 7 TIA Portal and WinCC TIA Portal V14 All versions V14 SP1 Update 6, SIMATIC STEP 7 TIA...
CVE-2018-11454
A vulnerability has been identified in SIMATIC STEP 7 TIA Portal and WinCC TIA Portal V10, V11, V12 All versions, SIMATIC STEP 7 TIA Portal and WinCC TIA Portal V13 All versions V13 SP2 Update 2, SIMATIC STEP 7 TIA Portal and WinCC TIA Portal V14 All versions V14 SP1 Update 6, SIMATIC STEP 7 TIA...
CVE-2018-11454
A vulnerability has been identified in SIMATIC STEP 7 TIA Portal and WinCC TIA Portal V10, V11, V12 All versions, SIMATIC STEP 7 TIA Portal and WinCC TIA Portal V13 All versions V13 SP2 Update 2, SIMATIC STEP 7 TIA Portal and WinCC TIA Portal V14 All versions V14 SP1 Update 6, SIMATIC STEP 7 TIA...