537 matches found
EUVD-2022-28120
Malicious code in bioql PyPI...
EUVD-2022-30420
Malicious code in bioql PyPI...
EUVD-2024-51140
Malicious code in bioql PyPI...
EUVD-2024-53143
Malicious code in bioql PyPI...
CVE-2025-8679
CVE-2025-8679 affects ExtremeGuest Essentials prior to 25.5.0. The captive-portal can permit unauthorized access through a manual brute-force process; under certain captive-portal SSID configurations, repeated login attempts may cause an unauthenticated device to be marked as authenticated and gr...
SonicWall Releases Advisory for Customers after Security Incident
SonicWall released a security advisory to assist their customers with protecting systems impacted by the MySonicWall cloud backup file incident. SonicWall’s investigation found that a malicious actor performed a series of brute force techniques against their MySonicWall.com web portal to gain...
CVE-2025-54810
CVE-2025-54810 affects Cognex In-Sight Explorer and In-Sight Camera Firmware. A proprietary protocol on TCP port 1069 handles management operations, including changing system properties. User management data (usernames and passwords) are transmitted over an unencrypted channel, enabling an adjace...
PT-2025-87: Incorrect session expiration in Fastwel PLC web server
The vulnerability was identified in Fastwel programmable controllers, versions 3.4.5.0 CPM810-03, 3.4.9.1 СPM723-01. The discovered vulnerability can be exploited by an attacker to gain unlimited access to a device by brute-forcing or compromising a session token. Vulnerability status: Confirmed ...
CVE-2025-9696 Use of Hard-coded Credentials in SunPower PVS6
The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the...
SunPower PVS6
RISK EVALUATION Successful exploitation of this vulnerability could allow attackers to gain full access to the device, enabling them to replace firmware, modify settings, disable the device, create SSH tunnels, and manipulate attached devices. 2. RECOMMENDED PRACTICES CISA recommends users take...
Mitsubishi Electric MELSEC iQ-F Series CPU Module
RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker the ability to obtain credential information by intercepting SLMP communication messages, and read or write the device values of the product by using the obtained credential information. In addition, the...
CVE-2025-41689
CVE-2025-41689 affects Wiesemann & Theis Motherbox 3, a measurement data centralization device. The vulnerability allows an unauthenticated remote attacker to access stored measurement data with read-only rights due to an access-control weakness. Impact per CVSS v3.1 is High (Network, no privileg...
CVE-2025-7770
Tigo Energy's CCA device is vulnerable to insecure session ID generation in their remote API. The session IDs are generated using a predictable method based on the current timestamp, allowing attackers to recreate valid session IDs. When combined with the ability to circumvent session ID...
Packet Power EMX and EG
RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain full access to the device without authentication. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimizing...
CVE-2025-20696
In DA, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege, if an attacker has physical access to the device, with no additional execution privileges needed. User interaction is needed for exploitation. Patch ID: ALPS09915215;...
CVE-2025-41687
An unauthenticated remote attacker may use a stack based buffer overflow in the u-link Management API to gain full access on the affected devices...
The vulnerability of the user interface of Juniper Networks Junos OS allows a hacker to gain access to the device.
The vulnerability of the user interface of Juniper Networks Junos OS is related to discrepancies in the data of the user interface. Exploiting this vulnerability can allow a malicious actor to gain access to the device remotely...
CVE-2025-41668
A low privileged remote attacker with file access can replace a critical file or folder used by the service security-profile to get read, write and execute access to any file on the device...
CVE-2025-41666
A low privileged remote attacker with file access can replace a critical file used by the watchdog to get read, write and execute access to any file on the device after the watchdog has been initialized...
CVE-2025-41668
CVE-2025-41668 describes a file-replacement vulnerability affecting Phoenix Contact devices (notably AXC F 1152 and related products). An attacker with low privilege and remote file access can replace a critical file or folder used by the service security-profile, enabling read, write and execute...