PT-2022-13834
Name of the Vulnerable Software and Affected Versions Delta Electronics DIAEnergie versions prior to 1.8.02.004 Description A blind SQL injection issue exists in the dlSlog.aspx file, allowing an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system...
PT-2022-13838
Name of the Vulnerable Software and Affected Versions Delta Electronics DIAEnergie versions prior to 1.8.02.004 Description A blind SQL injection issue exists in the DIAE privgrpHandler.ashx handler, allowing an attacker to inject arbitrary SQL queries. This enables the retrieval and modification...
CVE-2022-1367: Improper Neutralization of Special Elements used in an SQL Command
Delta Electronics DIAEnergie All versions prior to 1.8.02.004 has a blind SQL injection vulnerability exists in HandlerTCV.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands...
PT-2022-13839
Name of the Vulnerable Software and Affected Versions Delta Electronics DIAEnergie versions prior to 1.8.02.004 Description A blind SQL injection issue exists in DIAE rltHandler.ashx, allowing an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system...
CVE-2022-1378: Improper Neutralization of Special Elements used in an SQL Command
Delta Electronics DIAEnergie All versions prior to 1.8.02.004 has a blind SQL injection vulnerability exists in DIAEpgHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands...
CVE-2022-1366: Improper Neutralization of Special Elements used in an SQL Command
Delta Electronics DIAEnergie All versions prior to 1.8.02.004 has a blind SQL injection vulnerability exists in HandlerChart.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands...
CVE-2022-1403 Delta Electronics ASDA-Soft Out-of-bounds Write
ASDA-Soft: Version 5.4.1.0 and prior does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds write condition...
CVE-2022-1403 Delta Electronics ASDA-Soft Out-of-bounds Write
ASDA-Soft: Version 5.4.1.0 and prior does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds write condition...
CVE-2022-1402 Delta Electronics ASDA-Soft Out-of-bounds Read
ASDA-Soft: Version 5.4.1.0 and prior does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition...
CVE-2022-1402 Delta Electronics ASDA-Soft Out-of-bounds Read
ASDA-Soft: Version 5.4.1.0 and prior does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition...
Delta Electronics DIAEnergie SQL注入漏洞
Delta Electronics DIAEnergie is an industrial energy management system for monitoring and analyzing energy consumption in real time, calculating energy consumption and load characteristics, optimizing equipment performance, improving production processes and maximizing energy efficiency. Delta...
Delta Electronics DIAEnergie SQL注入漏洞
Delta Electronics DIAEnergie is an industrial energy management system for monitoring and analyzing energy consumption in real time, calculating energy consumption and load characteristics, optimizing equipment performance, improving production processes and maximizing energy efficiency. Delta...
Delta Industrial Automation DMARS DSCP Scope File Parsing XML External Entity Processing Information Disclosure Vulnerability
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Delta Industrial Automation DMARS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists...
(0Day) Delta Industrial Automation DRAS Project File Parsing XML External Entity Processing Information Disclosure Vulnerability
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Delta Industrial Automation DRAS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists...
(0Day) Delta Industrial Automation DRAS DSCP Scope File Parsing XML External Entity Processing Information Disclosure Vulnerability
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Delta Industrial Automation DRAS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists...
Delta Electronics DIAEnergie SQL注入漏洞
Delta Electronics DIAEnergie is an industrial energy management system for monitoring and analyzing energy consumption in real time, calculating energy consumption and load characteristics, optimizing equipment performance, improving production processes and maximizing energy efficiency. Delta...
Delta Electronics DIAEnergie SQL注入漏洞
Delta Electronics DIAEnergie is an industrial energy management system for monitoring and analyzing energy consumption in real time, calculating energy consumption and load characteristics, optimizing equipment performance, improving production processes and maximizing energy efficiency. Delta...
Delta Electronics DIAEnergie SQL注入漏洞
Delta Electronics DIAEnergie is an industrial energy management system for monitoring and analyzing energy consumption in real time, calculating energy consumption and load characteristics, optimizing equipment performance, improving production processes and maximizing energy efficiency. Delta...
Delta Electronics DIAEnergie SQL注入漏洞
Delta Electronics DIAEnergie is an industrial energy management system for monitoring and analyzing energy consumption in real time, calculating energy consumption and load characteristics, optimizing equipment performance, improving production processes and maximizing energy efficiency. Delta...
Delta Electronics DIAEnergie SQL注入漏洞
Delta Electronics DIAEnergie is an industrial energy management system for monitoring and analyzing energy consumption in real time, calculating energy consumption and load characteristics, optimizing equipment performance, improving production processes and maximizing energy efficiency. Delta...