4668 matches found
CISA Alerts on Critical Security Vulnerabilities in Industrial Control Systems
The U.S. Cybersecurity and Infrastructure Security Agency CISA has released eight Industrial Control Systems ICS advisories on Tuesday, warning of critical flaws affecting equipment from Delta Electronics and Rockwell Automation. This includes 13 security vulnerabilities in Delta Electronics'...
CISA Alerts on Critical Security Vulnerabilities in Industrial Control Systems
The U.S. Cybersecurity and Infrastructure Security Agency CISA has released eight Industrial Control Systems ICS advisories on Tuesday, warning of critical flaws affecting equipment from Delta Electronics and Rockwell Automation. This includes 13 security vulnerabilities in Delta Electronics'...
PT-2023-2320 · Delta Electronics · Infrasuite Device Master
Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to errors in code generation, allowing an attacker to remotely execute arbitrary code by running Lua scripts. This could enable an attacker t...
PT-2023-2353 · Delta Electronics · Infrasuite Device Master
Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges...
PT-2023-2322 · Delta Electronics · Infrasuite Device Master
Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to improper access control, which could allow an attacker to retrieve Gateway configuration files and obtain plaintext credentials. This coul...
PT-2023-2346 · Delta Electronics · Infrasuite Device Master
Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to insufficient input validation in the Delta Electronics InfraSuite Device Master software, which could allow an unauthenticated attacker to...
PT-2023-2196 · Delta Electronics · Infrasuite Device Master
Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to a deserialization vulnerability in the Device-gateway service, which could allow deserialization of requests prior to authentication,...
PT-2023-2324 · Delta Electronics · Infrasuite Device Master
Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to the installation of incorrect directory permissions, which could allow an attacker to escalate their privileges locally. Recommendations:...
PT-2023-1954 · Delta Electronics · Infrasuite Device Master
Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to a lack of authentication for a critical function, which could allow an attacker to achieve unauthenticated remote code execution in the...
PT-2023-2345 · Delta Electronics · Infrasuite Device Master
Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to insufficient authorization mechanisms in the Device-Gateway service of the Delta Electronics InfraSuite Device Master software. This can b...
Delta DOPSoft <= 4.00.16.22 Multiple Vulnerabilities
The version of Delta DOPSoft installed on the remote host is prior to or equal to 4.00.16.22. It is, therefore, affected by multiple vulnerabilities as referenced in the CISA ICSA-23-031-01 advisory. - Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to a stack-based buffer...
PT-2023-2188 · Delta Electronics · Infrasuite Device Master
Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to a deserialization vulnerability in the Device-DataCollect service, which could allow deserialization of requests prior to authentication,...
Delta DOPSoft All Versions Out-of-bounds Read Vulnerability
Delta DOPSoft is installed on the remote host. It is, therefore, affected by vulnerabilities as referenced in the CISA ICSA-22-244-01 advisory. - Two out-of-bounds read conditions may occur due to the affected product not properly sanitizing input while processing specific project files, which ma...
DOPSoft Malformed File Handler Code Execution
The vulnerability of the Malformed File Handler component in DOPSoft software, which is used for programming operator panels by Delta Electronics, relates to writing beyond the buffer boundaries. Exploiting this vulnerability could allow an attacker to execute arbitrary code using a specially...
lform/net_diagnose Component Arbitrary Command Execution
The vulnerability of the lform/netdiagnose component of Delta Electronics’ DX-2100-L1-CN router software exists due to the lack of measures taken to neutralize the special elements used in the operating system commands. Exploiting this vulnerability allows a remote attacker to execute arbitrary...
Delta Electronics DX-2100-L1-CN Router Code Execution
The vulnerability of the web configuration service of Delta Electronics DX-2100-L1-CN microprogrammed router software exists due to the lack of measures taken to protect the web page structure. Exploiting this vulnerability allows a remote attacker to execute arbitrary code...
DOPSoft Buffer Overflow
The vulnerability of the DOPSoft software, designed for programming operator panels by Delta Electronics, is due to buffer overflow on the stack. Exploiting this vulnerability allows an attacker to execute arbitrary code using a specially crafted file...
Delta Electronics DIAEnergie 授权问题漏洞
Delta Electronics DIAEnergie is an industrial energy management system from Delta Electronics Taiwan, China used to monitor and analyze energy consumption in real time, calculate energy consumption and load characteristics, optimize equipment performance, improve production processes and maximize...
CISA Releases Fifteen Industrial Control Systems Advisories
CISA released fifteen 15 Industrial Control Systems ICS advisories on February 16, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. CISA encourages users and administrators to review the newly released ICS advisories f...
SUSE CVE-2010-3846