Lucene search
+L

4086 matches found

Positive Technologies
Positive Technologies
added 2023/03/21 12:0 a.m.7 views

PT-2023-2196 · Delta Electronics · Infrasuite Device Master

Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to a deserialization vulnerability in the Device-gateway service, which could allow deserialization of requests prior to authentication,...

9CVSS9AI score0.01255EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
added 2023/03/21 12:0 a.m.6 views

PT-2023-2188 · Delta Electronics · Infrasuite Device Master

Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to a deserialization vulnerability in the Device-DataCollect service, which could allow deserialization of requests prior to authentication,...

7.8CVSS8AI score0.00314EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2023/03/21 12:0 a.m.19 views

Delta DOPSoft All Versions Out-of-bounds Read Vulnerability

Delta DOPSoft is installed on the remote host. It is, therefore, affected by vulnerabilities as referenced in the CISA ICSA-22-244-01 advisory. - Two out-of-bounds read conditions may occur due to the affected product not properly sanitizing input while processing specific project files, which ma...

7.5CVSS7.4AI score0.00356EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2023/03/21 12:0 a.m.6 views

PT-2023-2322 · Delta Electronics · Infrasuite Device Master

Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to improper access control, which could allow an attacker to retrieve Gateway configuration files and obtain plaintext credentials. This coul...

7.8CVSS7.3AI score0.00571EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2023/03/21 12:0 a.m.6 views

PT-2023-1954 · Delta Electronics · Infrasuite Device Master

Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to a lack of authentication for a critical function, which could allow an attacker to achieve unauthenticated remote code execution in the...

9.8CVSS10AI score0.01079EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
added 2023/03/21 12:0 a.m.11 views

PT-2023-2324 · Delta Electronics · Infrasuite Device Master

Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to the installation of incorrect directory permissions, which could allow an attacker to escalate their privileges locally. Recommendations:...

7.8CVSS7.5AI score0.00164EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2023/03/21 12:0 a.m.40 views

Delta DOPSoft <= 4.00.16.22 Multiple Vulnerabilities

The version of Delta DOPSoft installed on the remote host is prior to or equal to 4.00.16.22. It is, therefore, affected by multiple vulnerabilities as referenced in the CISA ICSA-23-031-01 advisory. - Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to a stack-based buffer...

7.8CVSS8.3AI score0.00245EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2023/03/21 12:0 a.m.7 views

PT-2023-2320 · Delta Electronics · Infrasuite Device Master

Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to errors in code generation, allowing an attacker to remotely execute arbitrary code by running Lua scripts. This could enable an attacker t...

9CVSS8.7AI score0.00835EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2023/03/21 12:0 a.m.6 views

PT-2023-2346 · Delta Electronics · Infrasuite Device Master

Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to insufficient input validation in the Delta Electronics InfraSuite Device Master software, which could allow an unauthenticated attacker to...

10CVSS8AI score0.00736EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2023/03/21 12:0 a.m.5 views

PT-2023-2345 · Delta Electronics · Infrasuite Device Master

Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to insufficient authorization mechanisms in the Device-Gateway service of the Delta Electronics InfraSuite Device Master software. This can b...

9CVSS8.6AI score0.00645EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2023/03/21 12:0 a.m.7 views

PT-2023-2353 · Delta Electronics · Infrasuite Device Master

Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master versions prior to 1.0.5 Description: The issue is related to a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges...

9CVSS8.6AI score0.00659EPSS
SaveExploits0References6
BDU FSTEC
BDU FSTEC
added 2023/03/06 12:0 a.m.8 views

The vulnerability of the lform/net_diagnose component of Delta Electronics’ DX-2100-L1-CN microprogramming system allows a hacker to execute arbitrary commands.

The vulnerability of the lform/netdiagnose component of Delta Electronics’ DX-2100-L1-CN router software exists due to the lack of measures taken to neutralize the special elements used in the operating system commands. Exploiting this vulnerability allows a remote attacker to execute arbitrary...

8.3CVSS7.5AI score0.02354EPSS
SaveExploits1References5Affected Software1
BDU FSTEC
BDU FSTEC
added 2023/03/06 12:0 a.m.11 views

The vulnerability of the web configuration service of Delta Electronics DX-2100-L1-CN microprogrammed router software allows a hacker to execute arbitrary code.

The vulnerability of the web configuration service of Delta Electronics DX-2100-L1-CN microprogrammed router software exists due to the lack of measures taken to protect the web page structure. Exploiting this vulnerability allows a remote attacker to execute arbitrary code...

9CVSS8.1AI score0.011EPSS
SaveExploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2023/03/06 12:0 a.m.8 views

The vulnerability of the DOPSoft software, designed for programming operator panels of Delta Electronics, arises from buffer overflows in the stack. This allows an attacker to execute arbitrary code.

The vulnerability of the DOPSoft software, designed for programming operator panels by Delta Electronics, is due to buffer overflow on the stack. Exploiting this vulnerability allows an attacker to execute arbitrary code using a specially crafted file...

7.8CVSS8AI score0.00245EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
added 2023/03/06 12:0 a.m.11 views

The vulnerability of the Malformed File Handler component in the DOPSoft software, which is used for programming operator panels of Delta Electronics, allows a hacker to execute arbitrary code.

The vulnerability of the Malformed File Handler component in DOPSoft software, which is used for programming operator panels by Delta Electronics, relates to writing beyond the buffer boundaries. Exploiting this vulnerability could allow an attacker to execute arbitrary code using a specially...

7.8CVSS7.8AI score0.00241EPSS
SaveExploits0References2Affected Software1
CNNVD
CNNVD
added 2023/02/17 12:0 a.m.7 views

Delta Electronics DIAEnergie 授权问题漏洞

Delta Electronics DIAEnergie is an industrial energy management system from Delta Electronics Taiwan, China used to monitor and analyze energy consumption in real time, calculate energy consumption and load characteristics, optimize equipment performance, improve production processes and maximize...

8.8CVSS8AI score0.00634EPSS
SaveExploits0References2
CISA
CISA
added 2023/02/16 12:0 a.m.27 views

CISA Releases Fifteen Industrial Control Systems Advisories

CISA released fifteen 15 Industrial Control Systems ICS advisories on February 16, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. CISA encourages users and administrators to review the newly released ICS advisories f...

1.7AI score
SaveExploits0References15
SUSE CVE
SUSE CVE
added 2023/02/15 5:56 a.m.4 views

SUSE CVE-2010-3846

Array index error in the applyrcschange function in rcs.c in CVS 1.11.23 allows local users to gain privileges via an RCS file containing crafted delta fragment changes that trigger a heap-based buffer overflow...

6.9CVSS7AI score0.00392EPSS
SaveExploits0References3
SUSE CVE
SUSE CVE
added 2023/02/15 5:22 a.m.4 views

SUSE CVE-2015-0838

Buffer overflow in the C implementation of the applydelta function in pack.c in Dulwich before 0.9.9 allows remote attackers to execute arbitrary code via a crafted pack file...

7.5CVSS9.5AI score0.03351EPSS
SaveExploits0References2
SUSE CVE
SUSE CVE
added 2023/02/15 5:6 a.m.5 views

SUSE CVE-2016-2191

The bmpreadrows function in pngxtern/pngxrbmp.c in OptiPNG before 0.7.6 allows remote attackers to cause a denial of service invalid memory write and crash via a series of delta escapes in a crafted BMP image...

6.5CVSS7.1AI score0.03519EPSS
SaveExploits1References3