Lucene search
+L

4086 matches found

CVE
CVE
added 2023/11/30 10:7 p.m.49 views

CVE-2023-46690

CVE-2023-46690 affects Delta Electronics InfraSuite Device Master (version 1.0.7 and earlier). The vulnerability is a path traversal flaw in the device master that allows an attacker to write to arbitrary files anywhere on the filesystem, potentially enabling remote code execution. Related adviso...

8.8CVSS9AI score0.01852EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2023/11/30 10:7 p.m.41 views

CVE-2023-46690 Delta Electronics InfraSuite Device Master Path Traversal

In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, which could lead to remote code execution...

8.8CVSS9.1AI score0.01852EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2023/11/30 10:5 p.m.30 views

CVE-2023-39226 Delta Electronics InfraSuite Device Master Exposed Dangerous Method Or Function

In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a single UDP packet...

9.8CVSS9.9AI score0.01175EPSS
SaveExploits0References1
CVE
CVE
added 2023/11/30 10:5 p.m.55 views

CVE-2023-39226

Delta Electronics InfraSuite Device Master (v1.0.7 and earlier) is affected by CVE-2023-39226, where an unauthenticated attacker can execute arbitrary code by sending a single UDP packet via the RunScript method (Exposed Dangerous Method or Function). The affected component is the RunScript funct...

9.8CVSS9.8AI score0.01175EPSS
SaveExploits0References1Affected Software1
CISA
CISA
added 2023/11/30 12:0 p.m.7 views

CISA Releases Four Industrial Control Systems Advisories

CISA released four Industrial Control Systems ICS advisories on November 30, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-23-334-01 Delta Electronics DOPSoft ICSA-23-334-02 Yokogawa STARDOM ICSA-23-334-03 PTC...

7.1AI score
SaveExploits0References4
CNNVD
CNNVD
added 2023/11/30 12:0 a.m.8 views

Delta Electronics InfraSuite Device Master Security Vulnerability

Delta Electronics InfraSuite Device Master is a device used to simplify and automate the monitoring of critical equipment from Delta Electronics Taiwan, China. A security vulnerability exists in Delta Electronics InfraSuite Device Master v.1.0.7 and prior versions, which originated from a...

8.8CVSS8AI score0.01852EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2023/11/30 12:0 a.m.7 views

Delta Electronics InfraSuite Device Master Security Vulnerability

Delta Electronics InfraSuite Device Master is a device used to simplify and automate the monitoring of critical equipment from Delta Electronics Taiwan, China. A security vulnerability exists in Delta Electronics InfraSuite Device Master version v.1.0.7 that originates from a vulnerability that...

9.8CVSS7.2AI score0.16573EPSS
SaveExploits0References1
Zero Day Initiative
Zero Day Initiative
added 2023/11/30 12:0 a.m.22 views

Delta Electronics InfraSuite Device Master Device-DataCollect Deserialization of Untrusted Data Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics InfraSuite Device Master. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Device-DataCollect service, which listens on TCP port 300...

9.8CVSS9.8AI score0.16573EPSS
SaveExploits0References1
Zero Day Initiative
Zero Day Initiative
added 2023/11/30 12:0 a.m.25 views

Delta Electronics InfraSuite Device Master UploadMedia Directory Traversal Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics InfraSuite Device Master. Authentication is required to exploit this vulnerability. The specific flaw exists within the UploadMedia function. The issue results from the lack of prop...

8.8CVSS9.7AI score0.01852EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2023/11/30 12:0 a.m.8 views

Delta Electronics InfraSuite Device Master Security Vulnerability

Delta Electronics InfraSuite Device Master is a device for simplifying and automating critical device monitoring from Delta Electronics, Taiwan, China. A security vulnerability exists in Delta Electronics InfraSuite Device Master version v.1.0.7, which originated from a vulnerability that could...

7.5CVSS6.8AI score0.01118EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2023/11/30 12:0 a.m.10 views

Delta Electronics InfraSuite Device Master Security Vulnerability

Delta Electronics InfraSuite Device Master is a device used to simplify and automate the monitoring of critical equipment from Delta Electronics Taiwan, China. A security vulnerability exists in Delta Electronics InfraSuite Device Master v.1.0.7 and prior versions that originated from a...

9.8CVSS7.8AI score0.01175EPSS
SaveExploits0References1
Zero Day Initiative
Zero Day Initiative
added 2023/11/30 12:0 a.m.23 views

Delta Electronics InfraSuite Device Master Device-Gateway Deserialization of Untrusted Data Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics InfraSuite Device Master. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Device-Gateway service, which listens on TCP port 3100 by...

9.8CVSS9.8AI score0.16573EPSS
SaveExploits0References1
Zero Day Initiative
Zero Day Initiative
added 2023/11/30 12:0 a.m.29 views

Delta Electronics InfraSuite Device Master RunScript Exposed Dangerous Method Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics InfraSuite Device Master. Authentication is not required to exploit this vulnerability. The specific flaw exists within the RunScript method. The issue results from an exposed...

9.8CVSS9.7AI score0.01175EPSS
SaveExploits0References1
CISA
CISA
added 2023/11/28 12:0 p.m.10 views

CISA Releases Four Industrial Control Systems Advisories

CISA released four Industrial Control Systems ICS advisories on November 28, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-23-331-01 Delta Electronics InfraSuite Device Master ICSA-23-331-02 Franklin Electric...

7AI score
SaveExploits0References4
ICS
ICS
added 2023/11/28 7:0 a.m.57 views

Delta Electronics InfraSuite Device Master

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity Vendor : Delta Electronics Equipment : InfraSuite Device Master Vulnerabilities : Path Traversal, Deserialization of Untrusted Data, Exposed Dangerous Method or Function. 2. RISK EVALUATION...

9.8CVSS9.7AI score0.16573EPSS
SaveExploits0References10
Positive Technologies
Positive Technologies
added 2023/11/28 12:0 a.m.9 views

PT-2023-7641 · Delta Electronics · Infrasuite Device Master

Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master version 1.0.7 Description: A vulnerability exists in Delta Electronics InfraSuite Device Master that allows an attacker to write to any file in any location of the filesystem, potentially leading to...

9CVSS8.9AI score0.01852EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
added 2023/11/28 12:0 a.m.11 views

PT-2023-7439 · Delta Electronics · Infrasuite Device Master

Name of the Vulnerable Software and Affected Versions: Delta Electronics InfraSuite Device Master version 1.0.7 Description: A vulnerability exists in Delta Electronics InfraSuite Device Master that allows an unauthenticated attacker to disclose user information through a single UDP packet, obtai...

7.8CVSS7.3AI score0.01118EPSS
SaveExploits0References7
BDU FSTEC
BDU FSTEC
added 2023/11/15 12:0 a.m.12 views

The vulnerability of the web server of Delta Electronics’ DX-3021L9 microprogrammed router software arises from insufficient validation of input data. This allows attackers to add, modify, or delete data.

The vulnerability of the web server of the microprogrammed routing software from Delta Electronics DX-3021L9 exists due to insufficient verification of input data. Exploiting this vulnerability can allow a remote attacker to add, modify, or delete data...

9.4CVSS7.8AI score0.04757EPSS
SaveExploits1References3Affected Software1
Zero Day Initiative
Zero Day Initiative
added 2023/11/14 12:0 a.m.24 views

Delta Electronics DIAScreen XLS File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics DIAScreen. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the...

7.8CVSS6.6AI score0.00207EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
added 2023/11/14 12:0 a.m.8 views

The vulnerability of the `git_delta_apply` function in the `delta.c` component of the Git methods implementation in the C language, Libgit2. This vulnerability allows an attacker to access confidential data and also trigger a denial-of-service attack.

The vulnerability of the gitdeltaapply function in the delta.c component of the Git methods implementation in the C language, part of Libgit2, relates to reading data beyond the allowable buffer size. Exploiting this vulnerability allows an attacker to gain access to confidential data and also...

9.4CVSS7.1AI score0.02051EPSS
SaveExploits0References9Affected Software2
Rows per page
Query Builder