Lucene search
+L

2492 matches found

Cvelist
Cvelist
added 2022/11/17 10:45 p.m.29 views

CVE-2022-43457 Delta Electronics DIAEnergie SQL Injection

SQL Injection in HandlerPageKID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network...

8.8CVSS9.2AI score0.00619EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2022/11/17 10:45 p.m.11 views

CVE-2022-43457 Delta Electronics DIAEnergie SQL Injection

SQL Injection in HandlerPageKID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network...

8.8CVSS8AI score0.00619EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/11/17 10:45 p.m.28 views

CVE-2022-43447 Delta Electronics DIAEnergie SQL Injection

SQL Injection in AMEBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network...

8.8CVSS9.2AI score0.00619EPSS
SaveExploits0References1
CVE
CVE
added 2022/11/17 10:45 p.m.65 views

CVE-2022-43447

Summary: CVE-2022-43447 is a SQL injection vulnerability in Delta Electronics DIAEnergie. The issue affects DIAEnergie versions prior to v1.9.02.001 (and earlier pre–1.9.01.002, 1.9.02.001, 1.9.03.001 as per ICS updates) that process requests via web components, notably the AM_EBillAnalysis.aspx ...

8.8CVSS9.1AI score0.00619EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2022/11/17 10:45 p.m.56 views

CVE-2022-43457

CVE-2022-43457 is a SQL injection vulnerability in Delta Electronics DIAEnergie, specifically in HandlerPage_KID.ashx. Affected versions are prior to v1.9.02.001 (and referenced variants in update notes suggest gaps up to v1.9.03.001). Exploitation appears to be network-based with low attack comp...

8.8CVSS9.1AI score0.00619EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
added 2022/11/17 10:45 p.m.8 views

CVE-2022-43447 Delta Electronics DIAEnergie SQL Injection

SQL Injection in AMEBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network...

8.8CVSS9.1AI score0.00619EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2022/11/17 12:0 a.m.9 views

PT-2022-26925 · Delta Electronics · Diaenergie

Name of the Vulnerable Software and Affected Versions: Delta Electronics DIAEnergie versions prior to v1.9.02.001 Description: The issue allows an attacker to inject SQL queries via Network in FtyInfoSetting.aspx. Recommendations: For versions prior to v1.9.02.001, update to version v1.9.02.001 o...

8.8CVSS8.8AI score0.07686EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2022/11/17 12:0 a.m.5 views

Delta Electronics DIAEnergie SQL注入漏洞

Delta Electronics DIAEnergie is an industrial energy management system from Delta Electronics Taiwan, China used to monitor and analyze energy consumption in real time, calculate energy consumption and load characteristics, optimize equipment performance, improve production processes and maximize...

8.8CVSS8.1AI score0.00619EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2022/11/17 12:0 a.m.9 views

PT-2022-26951 · Delta Electronics · Delta Electronics Diaenergie

Name of the Vulnerable Software and Affected Versions: Delta Electronics DIAEnergie versions prior to v1.9.02.001 Description: The issue allows an attacker to inject SQL queries via the network. This is related to SQL Injection in HandlerTag KID.ashx. Recommendations: For versions prior to...

8.8CVSS8.9AI score0.00685EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2022/11/10 12:0 a.m.6 views

Delta Electronics DIAEnergie SQL注入漏洞

Delta Electronics DIAEnergie is an industrial energy management system from Delta Electronics Taiwan, China used to monitor and analyze energy consumption in real time, calculate energy consumption and load characteristics, optimize equipment performance, improve production processes and maximize...

8.8CVSS8.3AI score0.07686EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2022/11/10 12:0 a.m.7 views

Delta Electronics DIAEnergie SQL注入漏洞

Delta Electronics DIAEnergie is an industrial energy management system from Delta Electronics Taiwan, China used to monitor and analyze energy consumption in real time, calculate energy consumption and load characteristics, optimize equipment performance, improve production processes and maximize...

8.8CVSS8.3AI score0.00619EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2022/11/10 12:0 a.m.8 views

Delta Electronics DIAEnergie SQL注入漏洞

Delta Electronics DIAEnergie is an industrial energy management system from Delta Electronics Taiwan, China used to monitor and analyze energy consumption in real time, calculate energy consumption and load characteristics, optimize equipment performance, improve production processes and maximize...

8.8CVSS8.3AI score0.00619EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2022/11/10 12:0 a.m.5 views

Delta Electronics DIAEnergie SQL注入漏洞

Delta Electronics DIAEnergie is an industrial energy management system from Delta Electronics Taiwan, China used to monitor and analyze energy consumption in real time, calculate energy consumption and load characteristics, optimize equipment performance, improve production processes and maximize...

8.8CVSS8.3AI score0.00685EPSS
SaveExploits0References3
ICS
ICS
added 2022/11/10 12:0 a.m.60 views

Delta Electronics DIAEnergie

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Delta Electronics Equipment: DIAEnergie --------- Begin Update B part 1 of 5 --------- Vulnerabilities: Cross-site Scripting, SQL Injection, Authorization Bypass --------- End Update B part 1 of 5...

8.8CVSS8.7AI score0.26572EPSS
SaveExploits0References5
CNNVD
CNNVD
added 2022/11/04 12:0 a.m.7 views

Delta Electronics Industrial Automation DIALink 路径遍历漏洞

Delta Electronics Industrial Automation DIALink is an industrial automation IoT device from Delta Electronics of Taiwan, China. A path traversal vulnerability exists in Delta Electronics Industrial Automation DIALink because it uses external input to construct a pathname that identifies a file or...

8.1CVSS7.6AI score0.02283EPSS
SaveExploits0References3
NVD
NVD
added 2022/10/31 8:15 p.m.27 views

CVE-2022-41644

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges...

8.8CVSS0.00705EPSS
SaveExploits0References1
OSV
OSV
added 2022/10/31 8:15 p.m.9 views

CVE-2022-41779

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote...

9.8CVSS6AI score0.01097EPSS
SaveExploits0References1
NVD
NVD
added 2022/10/31 8:15 p.m.34 views

CVE-2022-41629

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as...

9.1CVSS0.00605EPSS
SaveExploits0References1
NVD
NVD
added 2022/10/31 8:15 p.m.19 views

CVE-2022-41772

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution...

9.8CVSS0.24945EPSS
SaveExploits0References1
NVD
NVD
added 2022/10/31 8:15 p.m.44 views

CVE-2022-41776

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrativ...

7.5CVSS0.00525EPSS
SaveExploits0References1
Rows per page
Query Builder