14 matches found

NVD
NVD
added 2026/06/02 2:16 p.m.12 views

CVE-2019-25717

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS0.00165EPSS
Exploits0References2
Cvelist
Cvelist
added 2026/06/02 1:42 p.m.34 views

CVE-2019-25717 Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS0.00165EPSS
Exploits0References2
EUVD
EUVD
added 2026/06/02 1:42 p.m.8 views

EUVD-2019-20155

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration...

5.3CVSS5.8AI score0.00165EPSS
Exploits0References2
CNNVD
CNNVD
added 2026/06/02 12:0 a.m.2 views

Dräger多款产品 安全漏洞

Dräger Infinity Delta, among others, are products of the German company Dräger. The Dräger Infinity Delta is a multi-parameter clinical monitor. The Dräger Infinity Kappa is a multi-parameter patient monitor. The Dräger Infinity Delta XL is a high-performance multi-parameter patient monitor...

5.3CVSS5.5AI score0.00165EPSS
Exploits0References2
NVD
NVD
added 2026/06/01 10:16 p.m.10 views

CVE-2019-25716

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...

7.1CVSS0.00204EPSS
Exploits0References2
Cvelist
Cvelist
added 2026/06/01 9:15 p.m.29 views

CVE-2019-25716 Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet

Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the...

7.1CVSS0.00204EPSS
Exploits0References2
CNNVD
CNNVD
added 2026/06/01 12:0 a.m.6 views

Dräger多款产品 安全漏洞

Dräger Infinity Delta, among others, are products of the German company Dräger. The Dräger Infinity Delta is a multi-parameter clinical monitor. The Dräger Infinity Kappa is a multi-parameter patient monitor. The Dräger Infinity Delta XL is a high-performance multi-parameter patient monitor...

7.1CVSS5.5AI score0.00204EPSS
Exploits0References1
Prion
Prion
added 2019/01/28 10:29 p.m.18 views

Design/Logic Flaw

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about internals of the...

3.3CVSS6.8AI score0.0078EPSS
Exploits0References2
Prion
Prion
added 2019/01/28 10:29 p.m.20 views

Default configuration

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient...

3.3CVSS6.5AI score0.00762EPSS
Exploits0References2
Cvelist
Cvelist
added 2019/01/28 10:0 p.m.21 views

CVE-2018-19010

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient...

6.4AI score0.00762EPSS
Exploits0References2
NVD
NVD
added 2019/01/28 9:29 p.m.18 views

CVE-2018-19012

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker ...

7.8CVSS7.7AI score0.0039EPSS
Exploits0References2
Prion
Prion
added 2019/01/28 9:29 p.m.19 views

Design/Logic Flaw

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker ...

7.2CVSS7.6AI score0.0039EPSS
Exploits0References2
CVE
CVE
added 2019/01/28 9:0 p.m.48 views

CVE-2018-19012

The CVE-2018-19012 issue affects Dräger Infinity Delta, Delta XL, Kappa, and Infinity Explorer C700 (all versions). The root cause is improper privilege management in a dialog that allows breaking out of kiosk mode, enabling an attacker to reach the underlying OS and take control of the system. T...

7.8CVSS7.6AI score0.0039EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2019/01/28 9:0 p.m.19 views

CVE-2018-19012

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker ...

7.7AI score0.0039EPSS
Exploits0References2