•added 2022/10/31 7:19 p.m.•77 views

CVE-2022-41779

Delta Electronics InfraSuite Device Master is affected by CVE-2022-41779. The issue is a deserialization of untrusted data in network packets that can be received from an attacker-controlled server, enabling remote code execution on versions 00.00.01a and prior. Evidence across sources confirms t...

9.8CVSS9.5AI score0.01191EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2022/10/31 7:19 p.m.•37 views

CVE-2022-41779

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote...

8.8CVSS9.7AI score0.01191EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2022/10/31 7:04 p.m.•9 views

CVE-2022-38142

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization...

9.8CVSS9.7AI score0.18212EPSS
SaveExploits0References1
CVE
CVE
•added 2022/10/31 7:04 p.m.•107 views

CVE-2022-38142

CVE-2022-38142 affects Delta Electronics InfraSuite Device Master, versions 00.00.01a and prior. The vulnerability arises from deserialization of untrusted data received through the Device-DataCollect/Device-Gateway interfaces, with the ZDI advisory noting a lack of proper validation on the port ...

9.8CVSS9.7AI score0.18212EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2022/10/31 7:04 p.m.•43 views

CVE-2022-38142

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization...

9.8CVSS9.9AI score0.18212EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/10/31 12:00 a.m.•5 views

CVE-2022-41644: Missing Authentication for Critical Function

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges...

8.8CVSS7.8AI score0.00766EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/10/31 12:00 a.m.•5 views

CVE-2022-41772: Improper Limitation of a Pathname to a Restricted Directory

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution...

9.8CVSS8.6AI score0.24945EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/10/31 12:00 a.m.•11 views

CVE-2022-41688: Missing Authentication for Critical Function

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to th...

9.8CVSS7.5AI score0.00714EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/10/31 12:00 a.m.•4 views

CVE-2022-41657: Improper Limitation of a Pathname to a Restricted Directory

Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces APIs. This could create arbitrary files, which could be used in API operations and could ultimately...

9.8CVSS7.7AI score0.20898EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/10/31 12:00 a.m.•6 views

CVE-2022-41779: Deserialization of Untrusted Data

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote...

9.8CVSS8.5AI score0.01191EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/10/31 12:00 a.m.•8 views

CVE-2022-40202: Missing Authentication for Critical Function

The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication...

9.8CVSS8.5AI score0.01404EPSS
SaveExploits0References2
Check Point Advisories
Check Point Advisories
•added 2022/10/31 12:00 a.m.•38 views

Delta Electronics DIAEnergie SQL Injection (CVE-2022-1366)

An SQL injection exists in Delta Industrial Automation DIAEnergie. The vulnerability is due to insufficient input validation when processing requests...

10CVSS4AI score0.19345EPSS
SaveExploits0
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/10/31 12:00 a.m.•9 views

CVE-2022-41629: Missing Authentication for Critical Function

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as...

9.1CVSS7.4AI score0.00667EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/10/31 12:00 a.m.•5 views

CVE-2022-38142: Deserialization of Untrusted Data

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization...

9.8CVSS8.6AI score0.18212EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2022/10/31 12:00 a.m.•12 views

CVE-2022-41776: Missing Authentication for Critical Function

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrativ...

7.5CVSS7.2AI score0.00579EPSS
SaveExploits0References2
Vulnrichment
Vulnrichment
•added 2022/10/27 8:15 p.m.•10 views

CVE-2022-41651 Delta Electronics DIAEnergie

The affected product DIAEnergie versions prior to v1.9.01.002 is vulnerable to a stored cross-site scripting vulnerability through the SetPF API...

8.7CVSS8AI score0.11111EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2022/10/27 8:15 p.m.•38 views

CVE-2022-41702 Delta Electronics DIAEnergie

The affected product DIAEnergie versions prior to v1.9.01.002 is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API...

8.7CVSS8.2AI score0.11111EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2022/10/27 8:15 p.m.•10 views

CVE-2022-41702 Delta Electronics DIAEnergie

The affected product DIAEnergie versions prior to v1.9.01.002 is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API...

8.7CVSS8AI score0.11111EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2022/10/27 8:15 p.m.•35 views

CVE-2022-41651 Delta Electronics DIAEnergie

The affected product DIAEnergie versions prior to v1.9.01.002 is vulnerable to a stored cross-site scripting vulnerability through the SetPF API...

8.7CVSS8.2AI score0.11111EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2022/10/27 8:15 p.m.•12 views

CVE-2022-40967 Delta Electronics DIAEnergie

The affected product DIAEnergie versions prior to v1.9.01.002 is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries...

8.8CVSS8.9AI score0.07686EPSS
SaveExploits0References1