Lucene search
+L

126 matches found

NVD
NVD
added 2020/08/26 4:15 p.m.17 views

CVE-2020-15483

An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access...

7.2CVSS6.5AI score0.00424EPSS
SaveExploits1References2
Prion
Prion
added 2020/08/26 4:15 p.m.26 views

Default credentials

An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access...

7.2CVSS6.5AI score0.00424EPSS
SaveExploits1References2
Cvelist
Cvelist
added 2020/08/26 3:37 p.m.32 views

CVE-2020-15483

An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access...

6.5AI score0.00424EPSS
SaveExploits1References2
CVE
CVE
added 2020/08/26 3:37 p.m.61 views

CVE-2020-15483

CVE-2020-15483 affects Nescomed Multipara Monitor M1000 devices. The issue is a passwordless, full-access shell via the physical UART debug port, granting local/physical access with high impact on confidentiality, integrity, and availability. Public documentation in NVD/Red Hat confirms the UART ...

7.2CVSS6.5AI score0.00424EPSS
SaveExploits1References2Affected Software1
Positive Technologies
Positive Technologies
added 2020/08/26 12:00 a.m.14 views

PT-2020-14450 · Nescomed · Nescomed Multipara Monitor M1000

Name of the Vulnerable Software and Affected Versions: Nescomed Multipara Monitor M1000 devices affected versions not specified Description: An issue was discovered where the physical UART debug port on the devices provides a shell without requiring a password, giving complete access...

7.2CVSS6.5AI score0.00424EPSS
SaveExploits1References3
CNVD
CNVD
added 2020/08/04 12:00 a.m.17 views

Schneider Electric Tricon TCM Model Information Disclosure Vulnerability

Schneider Electric Tricon TCM Model 4351 and others are a communication module from Schneider Electric, France. An information disclosure vulnerability exists in the Schneider Electric Tricon TCM Model that stems from an older version of the program's debug port account being visible on the...

7.5CVSS6.5AI score0.01308EPSS
SaveExploits0References1
NVD
NVD
added 2020/07/23 9:15 p.m.25 views

CVE-2020-7491

VERSION NOT SUPPORTED WHEN ASSIGNED A legacy debug port account in TCMs installed in Tricon system versions 10.2.0 through 10.5.3 is visible on the network and could allow inappropriate access. This vulnerability was remediated in TCM version 10.5.4...

7.5CVSS8AI score0.01308EPSS
SaveExploits0References2
OSV
OSV
added 2020/07/23 9:15 p.m.10 views

CVE-2020-7491

VERSION NOT SUPPORTED WHEN ASSIGNED A legacy debug port account in TCMs installed in Tricon system versions 10.2.0 through 10.5.3 is visible on the network and could allow inappropriate access. This vulnerability was remediated in TCM version 10.5.4...

7.5CVSS7.2AI score0.01308EPSS
SaveExploits0References2
Prion
Prion
added 2020/07/23 9:15 p.m.27 views

Design/Logic Flaw

VERSION NOT SUPPORTED WHEN ASSIGNED A legacy debug port account in TCMs installed in Tricon system versions 10.2.0 through 10.5.3 is visible on the network and could allow inappropriate access. This vulnerability was remediated in TCM version 10.5.4...

5CVSS7.9AI score0.01308EPSS
SaveExploits0References2Affected Software7
attackerkb
attackerkb
added 2020/07/23 9:15 p.m.5 views

CVE-2020-7491

VERSION NOT SUPPORTED WHEN ASSIGNED A legacy debug port account in TCMs installed in Tricon system versions 10.2.0 through 10.5.3 is visible on the network and could allow inappropriate access. This vulnerability was remediated in TCM version 10.5.4...

7.5CVSS7.3AI score0.01308EPSS
SaveExploits0References4
CVE
CVE
added 2020/07/23 8:46 p.m.68 views

CVE-2020-7491

CVE-2020-7491 is an improper access control flaw in Schneider Electric Triconex legacy equipment. A legacy debug port account in Tricon system TCMs (Models 4351/4352, 4351A/B, 4352A/B) installed in Tricon v10.0–10.5.3 is visible on the network, potentially allowing inappropriate access. This vuln...

7.5CVSS7.5AI score0.01308EPSS
SaveExploits0References2Affected Software1
NVD
NVD
added 2020/04/14 8:15 p.m.18 views

CVE-2019-10939

A vulnerability has been identified in TIM 3V-IE incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE Advanced incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE DNP3 incl. SIPLUS NET variants All versions V3.3, TIM 4R-IE incl. SIPLUS NET variants All versions V2.8, TIM 4R-IE DNP3 incl...

9.8CVSS9.2AI score0.01116EPSS
SaveExploits0References1
OSV
OSV
added 2020/04/14 8:15 p.m.11 views

CVE-2019-10939

A vulnerability has been identified in TIM 3V-IE incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE Advanced incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE DNP3 incl. SIPLUS NET variants All versions V3.3, TIM 4R-IE incl. SIPLUS NET variants All versions V2.8, TIM 4R-IE DNP3 incl...

9.8CVSS7.2AI score0.01116EPSS
SaveExploits0References1
Prion
Prion
added 2020/04/14 8:15 p.m.19 views

Design/Logic Flaw

A vulnerability has been identified in TIM 3V-IE incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE Advanced incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE DNP3 incl. SIPLUS NET variants All versions V3.3, TIM 4R-IE incl. SIPLUS NET variants All versions V2.8, TIM 4R-IE DNP3 incl...

6.8CVSS9AI score0.01116EPSS
SaveExploits0References1Affected Software5
CVE
CVE
added 2020/04/14 7:50 p.m.76 views

CVE-2019-10939

The CVE-2019-10939 issue affects Siemens TIM 3V-IE, TIM 3V-IE Advanced, TIM 3V-IE DNP3, TIM 4R-IE, and TIM 4R-IE DNP3 (SIPLUS NET variants) with open debug port exposure under the condition that the device IP is 192.168.1.2. The root cause is an open debug port that can be accessed by a network-a...

9.8CVSS8.9AI score0.01116EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/04/14 7:50 p.m.36 views

CVE-2019-10939

A vulnerability has been identified in TIM 3V-IE incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE Advanced incl. SIPLUS NET variants All versions V2.8, TIM 3V-IE DNP3 incl. SIPLUS NET variants All versions V3.3, TIM 4R-IE incl. SIPLUS NET variants All versions V2.8, TIM 4R-IE DNP3 incl...

9AI score0.01116EPSS
SaveExploits0References1
ICS
ICS
added 2020/04/14 12:00 a.m.51 views

Siemens TIM 3V-IE and 4R-IE Family Devices

1. EXECUTIVE SUMMARY CVSS v3 9.0 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: TIM 3V-IE and 4R-IE Family Devices Vulnerability: Active Debug Code 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker with network access to gain full...

9.8CVSS9.8AI score0.01116EPSS
SaveExploits0References9
OpenVAS
OpenVAS
added 2020/01/29 12:00 a.m.65 views

RICOH Printers 'CVE-2019-14302' Debug Port Vulnerability

Multiple RICOH printers and multifunction printers are prone to a vulnerability where a debug port can be used. Copyright C 2020 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifie...

7.2CVSS7.3AI score0.00374EPSS
SaveExploits0References1
OSV
OSV
added 2020/01/10 6:15 p.m.15 views

CVE-2019-14302

On Ricoh SP C250DN 1.06 devices, a debug port can be used...

6.8CVSS6.7AI score0.00374EPSS
SaveExploits0References2
NVD
NVD
added 2020/01/10 6:15 p.m.26 views

CVE-2019-14302

On Ricoh SP C250DN 1.06 devices, a debug port can be used...

7.2CVSS6.6AI score0.00374EPSS
SaveExploits0References2