CVE-2020-12048
Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption e.g., TLS/SSL when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker wi...
Design/Logic Flaw
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
Design/Logic Flaw
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
Design/Logic Flaw
Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption e.g., TLS/SSL when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker wi...
CVE-2020-12036
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
CVE-2020-12037
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...
CVE-2020-12048
CVE-2020-12048 affects Baxter’s Phoenix Hemodialysis Delivery System software versions 3.36 and 3.40. The vulnerability is cleartext transmission of sensitive data (CWE-319): the system does not support data-in-transit encryption (e.g., TLS/SSL) when sending treatment and prescription data over t...
CVE-2020-12048
Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption e.g., TLS/SSL when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker wi...
CVE-2020-5367
Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this...
Input validation
Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this...
BIOTRONIK CardioMessenger II-S Authorization Issue Vulnerability (CNVD-2020-52054)
The Biotronik CardioMessenger II-S is a portable medical monitoring device from Biotronik Germany. A security vulnerability exists in the Biotronik CardioMessenger II-S T-Line T4APP version 2.20 and II-S GSM T4APP version 2.20, which originates from a program that can recover format-stored...
The vulnerability of the Enterprise Resource Management System “Galaktika ERP” allows a perpetrator to execute arbitrary codes.
The vulnerability of the “Update Manager” component of the enterprise resource management system Galaktika ERP is related to the lack of protection for transmitted data. Exploiting this vulnerability allows a malicious actor, who operates remotely and has access to the update server, to execute...
CVE-2019-3751
Dell EMC Enterprise Copy Data Management eCDM versions 1.0, 1.1, 2.0, 2.1, and 3.0 contain a certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and...
Input validation
Dell EMC Enterprise Copy Data Management eCDM versions 1.0, 1.1, 2.0, 2.1, and 3.0 contain a certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and...
CVE-2019-3751
Dell EMC Enterprise Copy Data Management eCDM versions 1.0, 1.1, 2.0, 2.1, and 3.0 contain a certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this vulnerability to carry out a man-in-the-middle attack by supplying a crafted certificate and...
Moderate severity vulnerability that affects com.rabbitmq:amqp-client and org.springframework.amqp:spring-amqp
Pivotal Spring AMQP, 1.x versions prior to 1.7.10 and 2.x versions prior to 2.0.6, expose a man-in-the-middle vulnerability due to lack of hostname validation. A malicious user that has the ability to intercept traffic would be able to view data in transit...
CVE-2018-11087
Pivotal Spring AMQP, 1.x versions prior to 1.7.10 and 2.x versions prior to 2.0.6, expose a man-in-the-middle vulnerability due to lack of hostname validation. A malicious user that has the ability to intercept traffic would be able to view data in transit...
Static Versus Dynamic Data Masking
Most participants in the trench warfare of IT security agree that the best way to protect data is to apply a layered approach to security. Data masking is a security and privacy enhancing technology recommended by industry analysts as a must-have data protection layer. While terminology varies...