191 matches found
CVE-2020-10611
CVE-2020-10611 is a real, externally exploitable type-confusion vulnerability in Triangle MicroWorks SCADA Data Gateway (DNP3 Data Sets). The Red Hat and NVD entries confirm it affects versions 2.41.0213–4.0.122 and 3.02.0697–4.0.122, enabling remote code execution with no authentication required...
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway is affected by CVE-2020-10613 (and related CVEs) in versions 2.41.0213–4.0.122 and 3.02.0697–4.0.122 due to an out-of-bounds read from improper validation of user-supplied data in DNP3 Data Sets. The vulnerability allows remote attackers to disclose sensitiv...
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...
CVE-2020-10615
CVE-2020-10615 affects Triangle MicroWorks SCADA Data Gateway, specifically versions 3.02.0697–4.0.122 and 2.41.0213–4.0.122. The root cause is improper validation of the length of user-supplied data prior to copying into a fixed-length stack-based buffer, causing a stack-based buffer overflow. T...
CVE-2020-10615
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...
Triangle MicroWorks SCADA Data Gateway Type Obfuscation Vulnerability
Triangle MicroWorks SCADA Data Gateway is a SCADA data gateway product from Triangle MicroWorks, Inc. A type confusion vulnerability exists in Triangle MicroWorks SCADA Data Gateway, which can be exploited by an attacker to execute arbitrary code...
Triangle MicroWorks SCADA Data Gateway Buffer Error Vulnerability
Triangle MicroWorks SCADA Data Gateway is a SCADA data gateway product from Triangle MicroWorks, Inc. An out-of-bounds read vulnerability exists in Triangle MicroWorks SCADA Data Gateway versions 3.02.0697 through 4.0.122 and 2.41.0213 through 4.0.122. The vulnerability stems from a lack of prope...
Cisco Packet Data Network Gateway Input Validation Vulnerability
Cisco Packet Data Network Gateway is a packet data network gateway device for 4G mobile core networks from Cisco. An input validation vulnerability exists in the peer-to-peer message handling in the Cisco Packet Data Network Gateway, which arises from the program failing to properly validate...
CVE-2018-0256
A vulnerability in the peer-to-peer message processing functionality of Cisco Packet Data Network Gateway could allow an unauthenticated, remote attacker to cause the Session Manager SESSMGR process on an affected device to restart, resulting in a denial of service DoS condition. The vulnerabilit...
Cisco ASR 5000 Series Packet Data Network Gateway Denial of Service Vulnerability
Cisco ASR 5000 Series is the 5000 series of wireless controller products from Cisco.Packet Data Network Gateway aka PGW is one of the packet data gateways. A security vulnerability exists in the General Packet Radio Switching Tunneling Protocol Version 1 GTPv1 implementation of the Cisco ASR 5000...
Triangle MicroWorks SCADA Data Gateway Detection (credentialed check)
Binary data scadaapptriangledatagatewayinstalled.nbin...
Triangle MicroWorks SCADA Data Gateway < 3.0.635 Multiple DoS Vulnerabilities
Binary data scadatrianglegateway30635.nbin...
Triangle MicroWorks SCADA Data Gateway < 3.3.729 Heartbeat Information Disclosure (Heartbleed)
Binary data scadatrianglegateway33729.nbin...
CVE-2014-2342
Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service excessive data processing via a crafted DNP3 packet...
CVE-2014-2343
Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service excessive data processing via a crafted DNP request over a serial line...
Code injection
Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service excessive data processing via a crafted DNP3 packet...
Design/Logic Flaw
Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service excessive data processing via a crafted DNP request over a serial line...
CVE-2014-2342 Triangle MicroWorks SCADA Data Gateway Resource Exhaustion
Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service excessive data processing via a crafted DNP3 packet...
CVE-2014-2342
Triangle MicroWorks SCADA Data Gateway vulnerable to DoS via crafted DNP3 packets. Affected: versions before 3.00.0635. Root cause: incorrect input validation leading to uncontrolled resource consumption (IP-connected DoS; serial connections also impacted with physical access). Impact: denial of ...
CVE-2014-2343
The CVE concerns Triangle MicroWorks SCADA Data Gateway prior to 3.00.0635, where a crafted DNP3 request on a serial line can cause an input-validation-based DoS due to excessive data processing. A related Nessus entry and ICS-CERT advisory confirm a broader DoS risk in affected releases, with IP...