•added 2026/09/03 6:31 p.m.•22 views

EUVD-2026-66251

Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service...

9.3CVSS5.5AI score0.0048EPSS
SaveExploits0References4
NVD
NVD
•added 2026/08/26 6:16 a.m.•22 views

CVE-2026-15203

Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service...

9.3CVSS0.0048EPSS
SaveExploits0References3
Vulnrichment
Vulnrichment
•added 2026/08/26 5:36 a.m.•21 views

CVE-2026-15203 Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software

Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service...

9.3CVSS6AI score0.0048EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2026/08/26 5:36 a.m.•46 views

CVE-2026-15203 Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software

Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service...

9.3CVSS0.0048EPSS
SaveExploits0References3
CVE
CVE
•added 2026/08/26 5:36 a.m.•75 views

CVE-2026-15203

Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 suffer from improper access control in debug and engineering interfaces that are accessible by default. An unauthenticated, network-based attacker can read and write internal values , upload and execute unsigned applications , and upload u...

9.3CVSS6AI score0.0048EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/08/26 12:00 a.m.•9 views

CVE-2026-15203: On-Chip Debug and Test Interface With Improper Access Control

Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service...

9.3CVSS6AI score0.0048EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2026/08/26 12:00 a.m.•25 views

PT-2026-81934

Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service...

9.3CVSS5.5AI score0.0048EPSS
SaveExploits0References3