1530 matches found
PT-2025-12392 · Xmedcon +1 · Xmedcon +1
Name of the Vulnerable Software and Affected Versions: xmedcon version 0.25.0 Description: A problem has been detected in the malloc function of the DICOM File Handler component, leading to an integer underflow. This issue can be exploited remotely. Recommendations: For xmedcon version 0.25.0,...
xmedcon 数字错误漏洞
xmedcon is an open source toolkit for medical image conversion from xmedcon open source. A numeric error vulnerability exists in xmedcon version 0.25.0, which stems from an integer underflow in the malloc function of the DICOM File Handler component...
CVE-2025-2480
Santesoft Sante DICOM Viewer Pro is vulnerable to an out-of-bounds write, which requires a user to open a malicious DCM file, resulting in execution of arbitrary code by a local attacker...
CVE-2025-2480
Santesoft Sante DICOM Viewer Pro is vulnerable to an out-of-bounds write, which requires a user to open a malicious DCM file, resulting in execution of arbitrary code by a local attacker...
CVE-2025-2480 Santesoft Sante DICOM Viewer Pro Out-of-bounds Write
Santesoft Sante DICOM Viewer Pro is vulnerable to an out-of-bounds write, which requires a user to open a malicious DCM file, resulting in execution of arbitrary code by a local attacker...
CVE-2025-2480
Santesoft Sante DICOM Viewer Pro is affected by an out-of-bounds write when a user opens a malicious DCM file, enabling arbitrary code execution by a local attacker. This is a local-exploit scenario, requiring user interaction to open the crafted file. Affected software is the Sante DICOM Viewer ...
CVE-2025-2480 Santesoft Sante DICOM Viewer Pro Out-of-bounds Write
Santesoft Sante DICOM Viewer Pro is vulnerable to an out-of-bounds write, which requires a user to open a malicious DCM file, resulting in execution of arbitrary code by a local attacker...
CISA Releases Five Industrial Control Systems Advisories
CISA released five Industrial Control Systems ICS advisories on March 20, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-079-01 Schneider Electric EcoStruxure™ ICSA-25-079-02 Schneider Electric Enerlin’X IFE...
Santesoft Sante DICOM Viewer Pro 缓冲区错误漏洞
Santesoft Sante DICOM Viewer Pro is a professional medical image DICOM workstation and viewer from Santesoft. It is used to view, edit and convert DICOM format medical image files. A buffer error vulnerability exists in Santesoft Sante DICOM Viewer Pro 14.1.2 and prior versions, which stems from...
SUSE CVE-2025-2357
A vulnerability was found in DCMTK 3.6.9. It has been declared as critical. This vulnerability affects unknown code of the component dcmjpls JPEG-LS Decoder. The manipulation leads to memory corruption. The attack can be initiated remotely. The exploit has been disclosed to the public and may be...
UBUNTU-CVE-2025-2357
A vulnerability was found in DCMTK 3.6.9. It has been declared as critical. This vulnerability affects unknown code of the component dcmjpls JPEG-LS Decoder. The manipulation leads to memory corruption. The attack can be initiated remotely. The exploit has been disclosed to the public and may be...
DCMTK 缓冲区错误漏洞
DCMTK is a collection of libraries and applications that implement most of the DICOM standards from the DCMTK open source. Software for examining, building, and converting DICOM image files, processing offline media, sending and receiving images over a network connection, and demonstrating image...
[SECURITY] Fedora 42 Update: dcmtk-3.6.9-2.fc42
DCMTK is a collection of libraries and applications implementing large parts the DICOM standard. It includes software for examining, constructing and converting DICOM image files, handling offline media, sending and receiving images over a network connection, as well as demonstrative image storag...
[SECURITY] Fedora 42 Update: gdcm-3.0.24-8.fc42
Grassroots DiCoM GDCM is a C++ library for DICOM medical files. It supports ACR-NEMA version 1 and 2 huffman compression is not supported, RAW, JPEG, JPEG 2000, JPEG-LS, RLE and deflated transfer syntax. It comes with a super fast scanner implementation to quickly scan hundreds of DICOM files. It...
The vulnerability of the DCM files on the medical image and data management system, as well as the Sante PACS Server, allows a perpetrator to trigger a service failure.
The vulnerability of the DCM files on the medical image and data management system, as well as those on the Sante PACS Server, is related to insufficient validation of input data. Exploiting this vulnerability can allow a malicious actor to cause service interruptions remotely...
The vulnerability of the DCM files on the medical image and data management system, as well as the Sante PACS Server, allows a hacker to write these files in the context of the current user.
The vulnerability of the DCM files on the medical image and data management system, as well as those on the Sante PACS Server, is related to incorrect restrictions on the path name for accessing the restricted catalog. Exploiting this vulnerability allows a malicious actor to write files under th...
CVE-2025-2029
A vulnerability was found in MicroDicom DICOM Viewer 2025.1 Build 3321. It has been classified as critical. Affected is an unknown function of the file mDicom.exe. The manipulation leads to memory corruption. The attack needs to be approached locally. It is recommended to upgrade the affected...
CVE-2025-2029
A vulnerability was found in MicroDicom DICOM Viewer 2025.1 Build 3321. It has been classified as critical. Affected is an unknown function of the file mDicom.exe. The manipulation leads to memory corruption. The attack needs to be approached locally. It is recommended to upgrade the affected...
CVE-2025-2029 MicroDicom DICOM Viewer mDicom.exe memory corruption
A vulnerability was found in MicroDicom DICOM Viewer 2025.1 Build 3321. It has been classified as critical. Affected is an unknown function of the file mDicom.exe. The manipulation leads to memory corruption. The attack needs to be approached locally. It is recommended to upgrade the affected...
CVE-2025-2029
The CVE-2025-2029 entry concerns MicroDicom DICOM Viewer 2025.1 Build 3321, where an unknown function in mDicom.exe allows memory corruption via local access. Affects the viewer’s ability to process certain inputs/files; impact is described as memory corruption with partial confidentiality/integr...