40 matches found
CVE-2016-9158
A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...
PT-2016-7672
Name of the Vulnerable Software and Affected Versions SIMATIC S7-300 CPU family versions all SIMATIC S7-400 PN/DP V6 and below CPU family versions all SIMATIC S7-400 PN/DP V7 CPU family versions all SIMATIC S7-400 V6 and earlier CPU family versions all SIMATIC S7-400 V7 CPU family versions all...
CVE-2016-9158: Improper Input Validation
A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...
CVE-2016-7113
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-7113
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-7113
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...
CVE-2016-7113
Siemens SIPROTEC 4/Compact EN100 Ethernet module vulnerabilities include CVE-2016-7113 (IMPROPER INPUT VALIDATION) where specially crafted packets to Port 80/TCP may cause the EN100 module to enter defect mode. Affected firmware variants are PROFINET IO (< V1.04.01), Modbus TCP (< V1.10.01/...
CVE-2016-3949: Undefined Security Weakness
Siemens SIMATIC S7-300 Profinet-enabled CPU devices with firmware before 3.2.12 and SIMATIC S7-300 Profinet-disabled CPU devices with firmware before 3.3.12 allow remote attackers to cause a denial of service defect-mode transition via crafted 1 ISO-TSAP or 2 Profibus packets...
PT-2015-5645
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-300 CPU devices affected versions not specified Description The issue allows remote attackers to cause a denial of service, resulting in a defect-mode transition. This can be achieved by sending crafted packets on either TCP...
CVE-2015-2177: Improper Input Validation
Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service defect-mode transition via crafted packets on 1 TCP port 102 or 2 Profibus...
CVE-2014-2256: Undefined Security Weakness
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257...
CVE-2014-2254: Undefined Security Weakness
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets, a different vulnerability than CVE-2014-2255...
CVE-2014-2258: Undefined Security Weakness
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets, a different vulnerability than CVE-2014-2259...
CVE-2014-2252: Undefined Security Weakness
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted PROFINET packets, a different vulnerability than CVE-2014-2253...
Siemens SIMATIC S7-1200多个漏洞
CVE ID: CVE-2014-2249,CVE-2014-2250,CVE-2014-2252,CVE-2014-2254,CVE-2014-2256,CVE-2014-2258 SIMATIC S7-1200是可编程控制器,可实现简单却高度精确的自动化任务。 Siemens SIMATIC S7-1200 4.0.0之前版本在实现上存在多个漏洞,可被恶意利用执行跨站请求伪造、劫持用户会话、造成拒绝服务。 1、向TCP端口443发送特制的数据包造成的错误可造成设备进入defect模式。 2、随机生成器内弱熵相关错误,可导致劫持另外用户的会话。...
CVE-2014-2259: Undefined Security Weakness
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets...
CVE-2014-2253: Undefined Security Weakness
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service defect-mode transition via crafted Profinet packets...
CVE-2014-2255: Undefined Security Weakness
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTP packets...
CVE-2013-2780: Undefined Security Weakness
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service defect-mode transition and control outage via crafted packets to UDP port 161 aka the SNMP port...
Siemens SIMATIC S7-400 PN CPU DoS
Overview Siemens has reported to ICS-CERT that denial-of-service DoS vulnerabilities exist in the SIMATIC S7-400 V6 and SIMATIC S7-400 V5 PN CPU products. Siemens has produced a firmware update that mitigates the vulnerability affecting the S7-400 V6. Siemens will not fix the vulnerability that...