Lucene search
+L

499 matches found

Tenable Nessus
Tenable Nessus
added 2017/05/19 12:00 a.m.84 views

Siemens SIMATIC WinCC (TIA Portal) 13 < 13 SP2 / 14 < 14 SP1 Multiple DoS

Binary data scadasiemenstiawincc13SP214SP1.nbin...

4.9CVSS6AI score0.01923EPSS
SaveExploits0References6
Prion
Prion
added 2017/05/11 10:29 a.m.32 views

Design/Logic Flaw

Specially crafted PROFINET DCP packets sent on a local Ethernet segment Layer 2 to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI...

6.1CVSS6.1AI score0.00906EPSS
SaveExploits0References4Affected Software65
NVD
NVD
added 2017/05/11 10:29 a.m.21 views

CVE-2017-2681

Specially crafted PROFINET DCP packets sent on a local Ethernet segment Layer 2 to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected...

7.1CVSS6.2AI score0.00906EPSS
SaveExploits0References5
NVD
NVD
added 2017/05/11 10:29 a.m.24 views

CVE-2017-6865

A vulnerability has been identified in Primary Setup Tool PST All versions V4.2 HF1, SIMATIC Automation Tool All versions V3.0, SIMATIC NET PC-Software All versions V14 SP1, SIMATIC PCS 7 V8.1 All versions, SIMATIC PCS 7 V8.2 All versions V8.2 SP1, SIMATIC STEP 7 TIA Portal V13 All versions V13...

6.5CVSS6.2AI score0.00469EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2017/05/11 10:00 a.m.47 views

CVE-2017-2681

Specially crafted PROFINET DCP packets sent on a local Ethernet segment Layer 2 to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected...

7.1CVSS6.2AI score0.00906EPSS
SaveExploits0References5
Vulnrichment
Vulnrichment
added 2017/05/11 10:00 a.m.18 views

CVE-2017-2681

Specially crafted PROFINET DCP packets sent on a local Ethernet segment Layer 2 to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected...

7.1CVSS6.2AI score0.00906EPSS
SaveExploits0References5
CVE
CVE
added 2017/05/11 10:00 a.m.117 views

CVE-2017-2681

CVE-2017-2681 affects Siemens PROFINET DCP; specially crafted DCP packets on a local Layer-2 Ethernet can cause denial of service in affected devices. The issue primarily impacts SIMATIC HMI Multi Panels, HMI Mobile Panels, and S7-300/S7-400 families, plus a wide range of PROFINET-enabled product...

7.1CVSS6.1AI score0.00906EPSS
SaveExploits0References5Affected Software1
OSV
OSV
added 2017/05/11 1:29 a.m.7 views

CVE-2017-2680

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment Layer 2. Human interaction is required to recover the systems. PROFIBUS interfaces are not affected...

6.5CVSS5.8AI score0.01149EPSS
SaveExploits0References10
Prion
Prion
added 2017/05/11 1:29 a.m.25 views

Design/Logic Flaw

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment Layer 2. Human interaction is required to recover the systems. PROFIBUS interfaces are not affected...

6.1CVSS6.2AI score0.01149EPSS
SaveExploits0References7Affected Software78
Cvelist
Cvelist
added 2017/05/11 1:00 a.m.45 views

CVE-2017-2680

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment Layer 2. Human interaction is required to recover the systems. PROFIBUS interfaces are not affected...

7.1CVSS6.2AI score0.01149EPSS
SaveExploits0References10
Vulnrichment
Vulnrichment
added 2017/05/11 1:00 a.m.31 views

CVE-2017-2680

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment Layer 2. Human interaction is required to recover the systems. PROFIBUS interfaces are not affected...

7.1CVSS6.4AI score0.01149EPSS
SaveExploits0References10
CVE
CVE
added 2017/05/11 1:00 a.m.172 views

CVE-2017-2680

CVE-2017-2680 is the Siemens PROFINET DCP Denial of Service vulnerability. Specially crafted PROFINET DCP broadcast packets can cause DoS on affected devices on a local Ethernet (Layer 2) segment, with recovery requiring human interaction. PROFIBUS interfaces are not affected. Affected products i...

7.1CVSS6AI score0.01149EPSS
SaveExploits0References10Affected Software1
ICS
ICS
added 2017/05/09 12:00 a.m.42 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update H)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...

7.1CVSS0.3AI score0.01149EPSS
SaveExploits0References75
ICS
ICS
added 2017/05/09 12:00 a.m.51 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update F)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...

6.5CVSS0.1AI score0.00469EPSS
SaveExploits0References40
ICS
ICS
added 2017/05/09 12:00 a.m.66 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update E)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...

6.5CVSS0.2AI score0.00469EPSS
SaveExploits0References39
ICS
ICS
added 2017/05/09 12:00 a.m.90 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update A)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the original advisory...

7.1CVSS0.5AI score0.01149EPSS
SaveExploits0References54
ICS
ICS
added 2017/05/09 12:00 a.m.49 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update E)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...

7.1CVSS0.3AI score0.01149EPSS
SaveExploits0References69
ICS
ICS
added 2017/05/09 12:00 a.m.51 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update J)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Improper Input Validation UPDATE INFORMATION This updated advisory is a follow-up to the updated...

7.1CVSS6.7AI score0.01149EPSS
SaveExploits0References80
ICS
ICS
added 2017/05/09 12:00 a.m.61 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update A)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the original advisory...

6.5CVSS0.5AI score0.00469EPSS
SaveExploits0References34
ICS
ICS
added 2017/05/09 12:00 a.m.53 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update C)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...

6.5CVSS0.4AI score0.00469EPSS
SaveExploits0References36
Rows per page