947 matches found
CVE-2022-25131
A command injection vulnerability in the function recvSlaveCloudCheckStatus of TOTOLINK Technology routers T6 V3Firmware T6V3V4.1.5cu.748B20211015 and T10 V2Firmware V4.1.8cu.5207B20210320 allows attackers to execute arbitrary commands via a crafted MQTT packet...
CVE-2022-25132
A command injection vulnerability in the function meshSlaveDlfw of TOTOLINK Technology router T6 V3Firmware T6V3V4.1.5cu.748B20211015 allows attackers to execute arbitrary commands via a crafted MQTT packet...
GO-2021-0227 Panic on crafted authentication request message in golang.org/x/crypto/ssh
Clients can cause a panic in SSH servers. An attacker can craft an authentication request message for the “gssapi-with-mic” method which will cause NewServerConn to panic via a nil pointer dereference if ServerConfig.GSSAPIWithMICConfig is nil...
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24314
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24312
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a...
CVE-2022-24315
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
Input validation
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
Out-of-bounds
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
Design/Logic Flaw
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a...
CVE-2022-24316
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...
Schneider Electric Interactive Graphical SCADA System security vulnerabilities
Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An authorization issue vulnerability exists in the Schneider Electric Interactive Graphical SCA...
CVE-2022-24311: Improper Limitation of a Pathname to a Restricted Directory
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends...
CVE-2022-24313: Buffer Copy without Checking Size of Input
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020...
CVE-2022-24312: Improper Limitation of a Pathname to a Restricted Directory
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a...
PT-2022-1814
Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System Data Server versions V15.0.0.22020 and prior Description The issue is related to an out-of-bounds read, which could cause memory leaks and potentially result in denial of service. This can happen when an...
mruby Denial of Service Vulnerability (CNVD-2022-08157)
mruby is a lightweight implementation of the Ruby language that runs Ruby code using interpreted mode and executes it in a virtual machine. A denial of service vulnerability exists in Mruby prior to version 3.2, which stems from a null pointer dereference in mruby that can be exploited by an...
Softing Industrial Automation OPC security vulnerability
Softing Industrial Automation OPC is an OPC OLE for Process Control solution from Softing Industrial Automation, Germany. A security vulnerability exists in the Softing Industrial Automation OPC UA c++ SDK, which can be exploited by a remote attacker to cause a denial of service DoS by sending a...