Lucene search
+L

819 matches found

OSV
OSV
added 2022/02/09 11:15 p.m.9 views

CVE-2022-24316

A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS5.8AI score0.01273EPSS
SaveExploits0References2
OSV
OSV
added 2022/02/09 11:15 p.m.6 views

CVE-2022-24315

A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS5.8AI score0.19255EPSS
SaveExploits0References2
OSV
OSV
added 2022/02/09 11:15 p.m.8 views

CVE-2022-24312

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a...

9.8CVSS6.3AI score0.03463EPSS
SaveExploits0References2
NVD
NVD
added 2022/02/09 11:15 p.m.26 views

CVE-2022-24316

A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS0.01273EPSS
SaveExploits0References2
OSV
OSV
added 2022/02/09 11:15 p.m.9 views

CVE-2022-24314

A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS7.1AI score0.18178EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2022/02/09 11:15 p.m.8 views

CVE-2022-24316

A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5CVSS6.6AI score0.01273EPSS
SaveExploits0References3
Prion
Prion
added 2022/02/09 11:15 p.m.20 views

Design/Logic Flaw

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a...

7.5CVSS9.6AI score0.03463EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2022/02/09 11:15 p.m.17 views

Out-of-bounds

A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

5CVSS7.4AI score0.19255EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2022/02/09 11:15 p.m.16 views

Input validation

A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

5CVSS7.4AI score0.01273EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2022/02/09 10:5 p.m.34 views

CVE-2022-24316

A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server V15.0.0.22020 and prior...

7.5AI score0.01273EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2022/02/09 12:0 a.m.7 views

Schneider Electric Interactive Graphical SCADA System 安全漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An authorization issue vulnerability exists in the Schneider Electric Interactive Graphical SCA...

7.5CVSS5.7AI score0.01206EPSS
SaveExploits0References7
CNVD
CNVD
added 2022/01/25 12:0 a.m.72 views

mruby Denial of Service Vulnerability (CNVD-2022-08157)

mruby is a lightweight implementation of the Ruby language that runs Ruby code using interpreted mode and executes it in a virtual machine. A denial of service vulnerability exists in Mruby prior to version 3.2, which stems from a null pointer dereference in mruby that can be exploited by an...

5.5CVSS5.4AI score0.0081EPSS
SaveExploits1References1
CNNVD
CNNVD
added 2021/11/10 12:0 a.m.10 views

Softing Industrial Automation OPC 安全漏洞

Softing Industrial Automation OPC is an OPC OLE for Process Control solution from Softing Industrial Automation, Germany. A security vulnerability exists in the Softing Industrial Automation OPC UA c++ SDK, which can be exploited by a remote attacker to cause a denial of service DoS by sending a...

7.5CVSS7.4AI score0.01267EPSS
SaveExploits0References2
OSV
OSV
added 2021/09/29 11:15 p.m.14 views

CVE-2021-41821

Wazuh Manager in Wazuh through 4.1.5 is affected by a remote Integer Underflow vulnerability that might lead to denial of service. A crafted message must be sent from an authenticated agent to the manager...

6.5CVSS6.6AI score
SaveExploits0References2
OSV
OSV
added 2021/09/17 6:15 p.m.7 views

CVE-2020-12080

A Denial of Service vulnerability has been identified in FlexNet Publisher's lmadmin.exe version 11.16.6. A certain message protocol can be exploited to cause lmadmin to crash...

7.5CVSS7AI score0.02111EPSS
SaveExploits1References3
CNNVD
CNNVD
added 2021/09/09 12:0 a.m.11 views

OpenBMC 授权问题漏洞

OpenBMC is a Linux distribution for managing controllers used in devices such as servers, top-of-rack switches or RAID devices. It uses Yocto, OpenEmbedded, systemd and D-Bus to easily customize your platform. OpenBMC suffers from an authorization issue vulnerability, which originates in OpenBMC...

10CVSS8.3AI score0.0301EPSS
SaveExploits1References6
CNNVD
CNNVD
added 2021/08/02 12:0 a.m.15 views

Swisslog Healthcare Nexus Panel 数字错误漏洞

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare. A buffer overflow vulnerability exists in Nexus Control Panel versions prior to 7.2.5.7. An attacker can exploit this vulnerability by sending a specially crafted message to the HMI to enable remote code execution...

9.8CVSS6.5AI score0.03264EPSS
SaveExploits0References6
Hacker One
Hacker One
added 2021/07/07 4:59 p.m.29 views

Mattermost: Specially crafted message request crashes the webapp for users who view the message

A specially crafted message request with a modified deletedat JSON parameter could crash the webapp for all users viewing the channel, or for anyone viewing a different channel if they switch to that channel afterward. This vulnerability could be exploited to prevent users from accessing a channe...

5.7CVSS5.4AI score0.00835EPSS
SaveExploits0
OSV
OSV
added 2021/06/22 7:15 p.m.11 views

CVE-2021-22383

There is an out-of-bounds read vulnerability in eCNS280TD V100R005C10 and eSE620X vESS V100R001C10SPC200, V100R001C20SPC200, V200R001C00SPC300. The vulnerability is due to a message-handling function that contains an out-of-bounds read vulnerability. An attacker can exploit this vulnerability by...

4.9CVSS5.8AI score0.00599EPSS
SaveExploits0References1
NCSC
NCSC
added 2021/06/17 12:0 a.m.16 views

Vulnerabilities fixed in Cisco Jabber for Windows

Vulnerabilities have been fixed in Cisco Jabber for Windows. A malicious party could exploit the vulnerabilities to obtain sensitive information or to cause a denial-of-service to the recipient of a specially prepared XMPP message. Cisco has released updates to fix the vulnerabilities. For more...

6.5CVSS6.8AI score0.00796EPSS
SaveExploits0
Rows per page
Query Builder