9619 matches found
firefox: thunderbird: Privilege escalation in Firefox Updater
A flaw was found in Firefox. The Mozilla Foundation's Security Advisory describes the following issue: Mozilla Firefox's update mechanism allowed a medium-integrity user process to interfere with the SYSTEM-level updater by manipulating the file-locking behavior. By injecting code into the...
CVE-2025-4660
A remote code execution vulnerability exists in the Windows agent component of SecureConnector due to improper access controls on a named pipe. The pipe is accessible to the Everyone group and does not restrict remote connections, allowing any network-based attacker to connect without...
CVE-2025-4660 Remote Code Execution in Windows Secure Connector/ HPS Inspection Engine via Insecure Named Pipe Access
A remote code execution vulnerability exists in the Windows agent component of SecureConnector due to improper access controls on a named pipe. The pipe is accessible to the Everyone group and does not restrict remote connections, allowing any network-based attacker to connect without...
CVE-2025-29973
Azure File Sync Elevation of Privilege (CVE-2025-29973): improper access control allows an authorized local attacker to escalate privileges. Affected product: Microsoft Azure File Sync. CVSS v3.1 base score 7.0 (HIGH). Remediation: patch/update from Microsoft; NCSC confirms fixes have been releas...
Schneider Electric Galaxy VS, Galaxy VL, Galaxy VXL (Update A)
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
Schneider Electric Modicon Controllers (Update B)
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
Schneider Electric PrismaSeT Active - Wireless Panel Server
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install physical controls so no unauthorized personnel can access...
Schneider Electric EcoStruxure Power Build Rapsody
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
CVE-2025-4660: Incorrect Default Permissions
A remote code execution vulnerability exists in the Windows agent component of SecureConnector due to improper access controls on a named pipe. The pipe is accessible to the Everyone group and does not restrict remote connections, allowing any network-based attacker to connect without...
PT-2025-21022
Name of the Vulnerable Software and Affected Versions Forescout SecureConnector versions 11.1.02.1019 through 11.3.6 Description A remote code execution vulnerability exists in the Windows agent component of SecureConnector due to improper access controls on a named pipe. The pipe is accessible t...
CVE-2025-31250
An information disclosure issue was addressed with improved privacy controls. This issue is fixed in macOS Sequoia 15.5. An app may be able to access sensitive user data...
CVE-2025-31250
An information disclosure issue was addressed with improved privacy controls. This issue is fixed in macOS Sequoia 15.5. An app may be able to access sensitive user data...
CVE-2025-31236
An information disclosure issue was addressed with improved privacy controls. This issue is fixed in macOS Sequoia 15.5. An app may be able to access sensitive user data...
CVE-2025-31236
An information disclosure issue was addressed with improved privacy controls. This issue is fixed in macOS Sequoia 15.5. An app may be able to access sensitive user data...
CVE-2025-31236
An information disclosure issue was addressed with improved privacy controls. This issue is fixed in macOS Sequoia 15.5. An app may be able to access sensitive user data...
CVE-2025-31236
An information disclosure issue exists in macOS , where an application may be able to access sensitive user data . The vulnerability was addressed by Apple through improved privacy controls . This issue is fixed in macOS Sequoia 15.5 . While the documents do not specify a particular component or ...
CVE-2025-31236
An information disclosure issue was addressed with improved privacy controls. This issue is fixed in macOS Sequoia 15.5. An app may be able to access sensitive user data...
CVE-2025-31250
An information disclosure issue in macOS Sequoia 15.5 allows an application to potentially access sensitive user data . The vulnerability was addressed by Apple through improved privacy controls . This issue is officially fixed in version 15.5 . Exploitation details are not provided in the docume...