The vulnerability of microprogramming software in embedded network control controllers of ASPECT Enterprise, NEXUS Series, and MATRIX Series systems relates to insecure privilege management, allowing attackers to elevate their privileges to the root level.
The vulnerability of microprogramming software in embedded network control controllers of ASPECT Enterprise, NEXUS Series, and MATRIX Series buildings is related to insecure privilege management. Exploiting this vulnerability can allow attackers to elevate their privileges to the root level...
The vulnerability of the FTP server function of microprogrammed logic controllers MELSEC RJ71EIP91, SW1DNN-EIPCT-BD, FX5-ENET/IP, SW1DNN-EIPCTFX5-BD allows a hacker to gain full access to the device.
The vulnerability of the FTP server functions of microprogrammed logic controllers such as MELSEC RJ71EIP91, SW1DNN-EIPCT-BD, FX5-ENET/IP, and SW1DNN-EIPCTFX5-BD is related to weak password requirements. Exploiting this vulnerability can allow a malicious actor to gain full access to the device...
The Software-Defined Car
Developers are starting to talk about the software-defined car. For decades, features have accumulated like cruft in new vehicles: a box here to control the antilock brakes, a module there to run the cruise control radar, and so on. Now engineers and designers are rationalizing the way they go...
Mitsubishi Electric 多款产品安全漏洞
The Mitsubishi Electric MELSEC iQ-R series and the Mitsubishi Electric MELSEC iQ-F series are both programmable logic controllers from Mitsubishi Electric Japan. A security vulnerability exists in several Mitsubishi Electric products, which is caused by a missing mask when entering a password fie...
Migrate Citrix Virtual Apps and Desktop databases to a new SQL server
Please follow these steps. 1.Close all instances of Citrix studio. Any configuration changes even through powershell to be stopped while following the stepsYou can power down DDCs to be extra cautious Take VM snapshot or take backup of all Delivery Controllers. 2. Take full backup of Site, Monito...
The vulnerability of the programming software for PLCs (programmable logic controllers), namely EcoStruxure Control Exper, arises from deficiencies in the separation of the controlled system area. This allows a intruder to carry out unauthorized maintenance actions.
The vulnerability of the EcoStruxure Control Exper programming tool for programmable logic controllers is related to deficiencies in the separation of the controlled system area. Exploiting this vulnerability could allow a malicious actor to perform a service failure remotely...
The vulnerability of the Modbus TCP protocol implementation in Schneider Electric Modicon programmable logic controllers allows a intruder to trigger a service failure.
The vulnerability of the Modbus TCP protocol implementation in Schneider Electric Modicon programmable logic controllers is related to insufficient checking of unusual or exceptional states. Exploiting this vulnerability could allow a malicious actor to cause malfunctions in the service operation...
The vulnerability of the PMBus interface of the VRM Voltage Regulator Module in Supermicro BMC controllers allows a hacker to physically destroy the CPU without the ability to restore it later.
The vulnerability of the PMBus interface of the VRM Voltage Regulator Module in Supermicro BMC controllers is related to the improper assignment of permissions for the critical resource. Exploiting this vulnerability may allow an attacker to physically disable the CPU without the possibility of...
The vulnerability of the Codesys software suite for industrial automation integrated into Schneider Electric’s programmable logic controllers allows a perpetrator to compromise data integrity.
The vulnerability of the Codesys software suite for industrial automation integrated into Schneider Electric’s programmable logic controllers is related to the disclosure of information in the incorrect data field. Exploiting this vulnerability could allow a malicious actor to compromise the...
The vulnerability of Rockwell Automation’s distributed controller software ArmorStart ST, related to deficiencies in input data validation by users, allows attackers to execute cross-site scripting (XSS) attacks.
The vulnerability of the microprogramming software for Rockwell Automation’s ArmorStart ST distributed controllers is related to deficiencies in the validation of user-input data. Exploiting this vulnerability could allow a malicious actor to perform cross-site scripting XSS attacks remotely...
The vulnerability of microprogrammed software in Mitsubishi Electric Corporation’s MELSEC iQ-F Series programmable logic controllers arises from buffer overflow on the stack, allowing an intruder to trigger a malfunction or execute arbitrary code.
The vulnerability of microprogrammed software in Mitsubishi Electric Corporation’s MELSEC iQ-F series programmable logic controllers arises due to buffer overflow on the stack. Exploiting this vulnerability allows a remote attacker to cause malfunctions in the system or execute arbitrary code by...
The vulnerability of the microprogramming software of Modicon PAC controllers and PLCs included in EcoStruxure Control Expert and EcoStruxure Process Expert allows a intruder to trigger maintenance failures.
The vulnerability of the microprogramming software of Modicon PAC controllers and PLCs included in EcoStruxure Control Expert and EcoStruxure Process Expert lies in the storage of data beyond the buffer boundaries. Exploiting this vulnerability could allow a malicious actor to trigger service...
The vulnerability of the microprogramming software of Schneider Electric’s programmable logic controllers Modicon M340, Modicon Quantum, and Modicon Premium allows a intruder to gain access to confidential data.
The vulnerability of microprogrammed software in Schneider Electric’s programmable logic controllers such as Modicon M340, Modicon Quantum, and Modicon Premium is related to the falsification of inter-site requests. Exploiting this vulnerability can allow a remote attacker to gain access to...
3s-smart Software Solutions CODESYS Development System 加密问题漏洞
3s-smart Software Solutions CODESYS Development System is a suite of programming tools for use in the field of industrial controllers and automation technology from 3s-smart Software Solutions GmbH 3s-smart Software Solutions of Germany. The 3s-smart Software Solutions CODESYS Development System...
The vulnerabilities of microprogrammed software in Nexx Garage Door Controllers (NXG-100B, NXG-200), Nexx Smart Plugs (NXPG-100W), and Nexx Smart Alarms (NXAL-100) stem from authentication procedures that have flaws. This allows intruders to register a signal that has already been registered by the device.
The vulnerabilities of the microprogrammed software of the Nexx Garage Door Controller NXG-100B, NXG-200, Nexx Smart Plug NXPG-100W, and Nexx Smart Alarm NXAL-100 are related to deficiencies in authentication procedures. Exploiting these vulnerabilities could allow an attacker, operating remotely...
Siemens SIMATIC Cloud Connect安全漏洞
SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices with OPC UA server interfaces to be connected as OPC UA clients. A denial of service vulnerability exists in Siemens SIMATIC Cloud Connect 7, which can be exploited b...
The vulnerability of the programming software for PLCs (programmable logic controllers), EcoStruxure Control Exper, allows a intruder to execute arbitrary code.
The vulnerability of the EcoStruxure Control Exper programming tool for programmable logic controllers is related to deficiencies in the separation of the controlled system area. Exploiting this vulnerability could allow a remote attacker to execute arbitrary code...
The vulnerability of microprogrammed software in logic controllers for building and facility control systems from Schneider Electric—such as spaceLYnk, Wiser for KNX (formerly homeLYnk), and FellerLYnk—is related to the lack of authentication for critical functions. This allows attackers to alter the configuration of the system.
The vulnerability of microprogramming software for logic controllers used in building and facility management systems from Schneider Electric—such as spaceLYnk, Wiser for KNX formerly homeLYnk, and FellerLYnk—is related to the absence of authentication for critical functions. Exploiting this...
The vulnerability of Omron CS/CJ automation controllers, related to the lack of authentication for critical functions, allows attackers to gain access to protected information.
The vulnerability of Omron CS/CJ automation controllers lies in the lack of authentication for critical functions. Exploiting this vulnerability can allow a malicious actor, operating remotely, to gain access to protected information...
Schneider Electric Easergy Builder Code Issue Vulnerability
Schneider Electric Easergy Builder is a set of configuration software for Easergy remote terminal units and controllers from Schneider Electric, France. A code issue vulnerability exists in Schneider Electric Easergy Builder version 1.7.23 and earlier, which stems from the presence of an...