Lucene search
+L

7 matches found

NVD
NVD
•added 2020/06/15 8:15 p.m.•39 views

CVE-2020-12001

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 an...

9.8CVSS0.11503EPSS
SaveExploits0References2
osv_cve
osv_cve
•added 2020/06/15 8:15 p.m.•19 views

CVE-2020-11999

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 an...

8.1CVSS7.3AI score0.02805EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2020/06/15 12:00 a.m.•1 views

PT-2020-12976

Name of the Vulnerable Software and Affected Versions FactoryTalk Linx versions 6.00 through 6.11 RSLinx Classic versions 4.11.00 and prior Connected Components Workbench versions 12 and prior ControlFLASH versions 14 and later ControlFLASH Plus versions 1 and later FactoryTalk Asset Centre...

7.5CVSS0.0523EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/06/15 12:00 a.m.•7 views

CVE-2020-12005: Unrestricted Upload of File with Dangerous Type

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 an...

7.8CVSS5.8AI score0.01842EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/06/15 12:00 a.m.•9 views

CVE-2020-11999: Improper Input Validation

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 an...

8.1CVSS6AI score0.02805EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2020/06/15 12:00 a.m.•7 views

PT-2020-12972

Name of the Vulnerable Software and Affected Versions FactoryTalk Linx versions 6.00 through 6.11 RSLinx Classic versions 4.11.00 and prior Connected Components Workbench versions 12 and prior ControlFLASH versions 14 and later ControlFLASH Plus versions 1 and later FactoryTalk Asset Centre...

8.1CVSS0.02805EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2020/06/15 12:00 a.m.•8 views

PT-2020-12974

Name of the Vulnerable Software and Affected Versions FactoryTalk Linx versions 6.00 through 6.11 RSLinx Classic versions 4.11.00 and prior Connected Components Workbench versions 12 and prior ControlFLASH versions 14 and later ControlFLASH Plus versions 1 and later FactoryTalk Asset Centre...

9.8CVSS0.11503EPSS
SaveExploits0References5
Rows per page
Query Builder