1488 matches found
CVE-2019-14199
creationtimestamp| type| source ---|---|--- 2026-05-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-16...
CVE-2019-13106
creationtimestamp| type| source ---|---|--- 2026-05-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-134-16...
Characterizing AI-Assisted Bot Traffic in Darknet Data: Implications for ICS and IIoT Security
The rise of automated scanning tools and AI assisted reconnaissance agents has significantly altered internet background traffic patterns, threatening the baseline assumptions underlying intrusion detection systems IDS deployed in critical infrastructure networks. This paper characterizes the...
On the (Non-)Resilience of Encrypted Controllers to Covert Attacks
The security of networked control systems NCS is receiving increasing attention from both cyber-security and system-theoretic perspectives. The former focuses on classical IT security goals such as confidentiality, integrity, and availability of process data, while the latter investigates tailore...
OT Cybersecurity Challenges for ICS in 2026
OT Cybersecurity Challenges for ICS in 2026 OT cybersecurity has become a board-level risk because industrial control systems are no longer isolated, predictable, or invisible to attackers. In 2026, security teams protecting manufacturing plants, utilities, transportation systems, energy...
CVE-2026-6411
creationtimestamp| type| source ---|---|--- 2026-05-07 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-127-01 2026-05-08 01:00:38+00:00| seen| https://bsky.app/profile/cve.skyfleet.blue/post/3mlcjqguyun2i...
NSA GRASSMARLIN
ADVISORY SUMMARY Successful exploitation of this vulnerability could allow an attacker to disclose sensitive information. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control...
IPDevicePenTest
IPDevicePenTest Automated penetration testing framework for...
Large Language Models As Explainable Cyberattack Detectors for Energy Industrial Control Systems
In modern energy systems, industrial control systems ICS and power-system SCADA require intrusion detection that is not only accurate but also auditable by operators. The ICS intrusion-detection landscape is currently dominated by established supervised detectors. In this paper, we study whether ...
Medoid Prototype Alignment for Cross-Plant Unknown Attack Detection in Industrial Control Systems
Deploying an intrusion detector trained in one industrial plant to another remains difficult because Industrial Control System ICS traffic is highly site-dependent, labels are scarce, and unseen attacks often appear after deployment. To address this challenge, this paper introduces a medoid...
GRASSMARLIN 代码问题漏洞
GRASSMARLIN is an open-source network security posture awareness tool for industrial control systems developed by the NSA Cybersecurity Directorate. Version GRASSMARLIN v3.2.1 contains a code vulnerability. This vulnerability stems from insufficient hardening of the XML parsing process, which may...
Hitachi Energy PCM600
SUMMARY Hitachi Energy is aware of a vulnerability that affects the Hitachi Energy PCM600 product versions listed in this document. An attacker successfully exploiting this vulnerability can impact integrity of the product. Please refer to the Recommended Immediate Actions for information about...
CVE-2026-3868
creationtimestamp| type| source ---|---|--- 2026-04-27 07:42:57+00:00| seen| https://cyber.gc.ca/en/alerts-advisories/control-systems-moxa-security-advisory-av26-393...
CVE-2026-3867
creationtimestamp| type| source ---|---|--- 2026-04-27 07:42:57+00:00| seen| https://cyber.gc.ca/en/alerts-advisories/control-systems-moxa-security-advisory-av26-393...
System-Aware Contextual Digital Twin for ICS Anomaly Diagnosis
Industrial Control Systems ICS integrate computing, physical processes, and communication to operate critical infrastructures such as power grids, water treatment plants, and oil and gas facilities. As ICS become increasingly targeted by cyberattacks, timely and reliable anomaly diagnosis is...
CVE-2026-6375
creationtimestamp| type| source ---|---|--- 2026-04-23 05:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-113-04 2026-04-23 23:26:58+00:00| seen| Telegram/EOmUzEDCCjVld0ErnrIDoAMYFcT1xcXC6s4XJmAqdlxQalE...
CVE-2026-3893
creationtimestamp| type| source ---|---|--- 2026-04-23 05:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-113-02...
On the Challenges of Holistic Intrusion Detection in ICS
Past attacks against industrial control systems ICS show that adversaries often target both the ICS network and the physical process to achieve potential catastrophic impact. To secure ICS, intrusion detection systems promise timely uncovering of such adversaries. However, as these detection...
CVE-2026-25720
creationtimestamp| type| source ---|---|--- 2026-04-21 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12...
CVE-2026-35503
creationtimestamp| type| source ---|---|--- 2026-04-21 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12 2026-04-24 01:18:04+00:00| seen| Telegram/S8ox9UMDIAxfwdU4Vdf7uPBMfOmVZYt0JmzSEaP85k3wGMs 2026-04-24 23:00:59+00:00| seen|...