1620 matches found
vulhub
This repository is an offensive tool for web application security training and testing. It is a collection of vulnerable web applications and tools for testing and training purposes. The repository contains a variety of vulnerable applications, including web servers, databases, and other web-base...
Keysight N6854A Geolocation server and N6841A RF Sensor software
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Keysight Technologies, Inc. Equipment: N6854A Geolocation server and N6841A RF Sensor software Vulnerabilities: Relative Path Traversal, Deserialization of Untrusted Data 2. RISK EVALUATION Successful...
subversion security update
An update is available for subversion. This update affects Rocky Linux 9. A Common Vulnerability Scoring System CVSS base score, which gives a detailed severity rating, is available for each vulnerability from the CVE list Subversion SVN is a concurrent version control system which enables one or...
CVE-2021-33021
xArrow SCADA versions 7.2 and prior is vulnerable to cross-site scripting due to parameter ‘edate’ of the resource xhisalarm.htm, which may allow an unauthorized attacker to execute arbitrary code...
Important: Red Hat Security Advisory: subversion:1.10 security update
An update for the subversion:1.10 module is now available for Red Hat Enterprise Linux 8.4 Extended Update Support. Red Hat Product Security has rated this update as having a security impact of Important. A Common Vulnerability Scoring System CVSS base score, which gives a detailed severity ratin...
Siemens SIMATIC WinCC Kiosk Mode Incorrect Initialization Vulnerability
SIMATIC PCS 7 is a process control system.SIMATIC WinCC is an automated data acquisition and monitoring SCADA system.SIMATIC WinCC Runtime Professional is a visual runtime platform for operators to control and monitor machines and equipment. A security vulnerability exists in Siemens SIMATIC WinC...
Siemens Desigo PXC and DXR Devices have unspecified vulnerabilities
Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...
Eaton Intelligent Power Manager
1. EXECUTIVE SUMMARY CVSS v3 5.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Eaton Equipment: Intelligent Power Manager IPM v1 Vulnerability: Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code...
The vulnerability of the server virtualization automation design (Automation Design) SCADA system Yokogawa CENTUM VP’s network protocol implementation allows a hacker to exploit the functions provided by the AD server.
The vulnerability of the server network protocol implementation in the Automation Design SCADA system of Yokogawa CENTUM VP is related to errors during the authentication process. Exploiting this vulnerability allows a malicious actor to utilize the features provided by the AD server...
Rockwell Automation ISaGRAF5 Runtime Cleartext Transmission of Sensitive Information (CVE-2020-25178)
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote...
Rockwell Automation ISaGRAF5 Runtime Uncontrolled Search Path Element (CVE-2020-25182)
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft...
Schneider Electric Cleartext Transmission of Sensitive Information in embedded Rockwell Automation ISaGRAF5 Runtime (CVE-2020-25178)
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote...
Elcomplus SmartPPT 跨站脚本漏洞
Elcomplus SmartPPT is an integrated voice and data scheduling software from Elcomplus USA. A cross-site scripting vulnerability exists in SmartPPT SCADA Server version v1.4, which allows an authenticated attacker to inject arbitrary JavaScript into critical parameters...
CVE-2021-46662
creationtimestamp| type| source ---|---|--- 2022-04-17 20:59:51+00:00| seen| https://t.me/cibsecurity/36611 2026-01-27 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02...
CVE-2022-27447
creationtimestamp| type| source ---|---|--- 2022-04-17 00:02:20+00:00| seen| https://t.me/cibsecurity/40769 2026-01-27 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02...
CVE-2022-27448
creationtimestamp| type| source ---|---|--- 2022-04-14 16:19:05+00:00| seen| https://t.me/cibsecurity/40761 2026-01-27 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02...
CVE-2022-27457
creationtimestamp| type| source ---|---|--- 2022-04-14 16:19:00+00:00| seen| https://t.me/cibsecurity/40758 2026-01-27 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02...
CVE-2022-27445
creationtimestamp| type| source ---|---|--- 2022-04-14 16:18:55+00:00| seen| https://t.me/cibsecurity/40753 2026-01-27 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02...
Feds: APTs Have Tools That Can Take Over Critical Infrastructure
Threat actors have built and are ready to deploy tools that can take over a number of widely used industrial control system ICS devices, which spells trouble for critical infrastructure providers—particularly those in the energy sector, federal agencies have warned. In a joint advisory, the...
CVE-2022-27381
creationtimestamp| type| source ---|---|--- 2022-04-13 00:17:09+00:00| seen| https://t.me/cibsecurity/40687 2026-01-27 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-02...