Lucene search
K

1568 matches found

ICS
ICS
added 2022/09/29 12:0 a.m.47 views

Hitachi Energy MicroSCADA Pro X SYS600

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: MicroSCADA Pro/X SYS600 Vulnerability: NULL Pointer Dereference, Infinite Loop 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause the affected...

7.5CVSS8.9AI score0.07539EPSS
Exploits2References5
ICS
ICS
added 2022/09/22 12:0 p.m.25 views

Control System Defense: Know the Opponent

Summary Traditional approaches to securing OT/ICS do not adequately address current threats. Operational technology/industrial control system OT/ICS assets that operate, control, and monitor day-to-day critical infrastructure and industrial processes continue to be an attractive target for...

9.6AI score
Exploits0References46
CISA
CISA
added 2022/09/22 12:0 a.m.21 views

CISA and NSA Publish Joint Cybersecurity Advisory on Control System Defense

CISA and the National Security Agency NSA have published a joint cybersecurity advisory about control system defense for operational technology OT and industrial control systems ICSs. Control System Defense: Know the Opponent is intended to provide critical infrastructure owners and operators wit...

2.6AI score
Exploits0References5
BDU FSTEC
BDU FSTEC
added 2022/09/19 12:0 a.m.3 views

The vulnerability of the centralized Subversion version control system, related to improper authorization, allows a violator to gain access to confidential data.

The vulnerability of the centralized version control system Subversion is related to improper authorization. Exploiting this vulnerability allows a malicious actor, operating remotely, to gain access to confidential data...

4.3CVSS5.8AI score0.0036EPSS
Exploits1References17Affected Software12
Positive Technologies
Positive Technologies
added 2022/09/19 12:0 a.m.3 views

PT-2022-18490 · Kingspan · Kingspan Tms300 Cs

Name of the Vulnerable Software and Affected Versions: Kingspan TMS300 CS versions affected versions not specified Description: The issue is due to the lack of adequately implemented access-control rules, allowing an attacker to view and modify application settings without authenticating by...

9.8CVSS8.8AI score0.00227EPSS
Exploits0References4
NVD
NVD
added 2022/08/31 4:15 p.m.11 views

CVE-2022-30317

Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access CDA EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell...

9.1CVSS0.00302EPSS
Exploits0References2
Prion
Prion
added 2022/08/31 4:15 p.m.18 views

Authentication flaw

Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access CDA EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell...

6.4CVSS9.2AI score0.00302EPSS
Exploits0References2Affected Software1
ICS
ICS
added 2022/08/30 12:0 a.m.42 views

Honeywell Experion LX

1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Honeywell Equipment: Experion LX Vulnerability: Missing Authentication for Critical Function CISA is aware of a public report known as “OT:ICEFALL” that details vulnerabilities found in multiple...

9.1CVSS9.6AI score0.00302EPSS
Exploits0References4
ICS
ICS
added 2022/08/30 12:0 a.m.44 views

Hitachi Energy RTU500 series

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 series Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could cause an internal buffer overflow, which can...

7.8CVSS7.9AI score0.00296EPSS
Exploits0References5
Trellix
Trellix
added 2022/08/25 12:0 a.m.15 views

A Door Isn’t a Door When It’s Ajar - Part 3

A Door Isn’t a Door When It’s Ajar - Part III By Trellix · August 25, 2022 This story was also written by Steve Povolny and Sam Quinn Contents Installing OnGuard by Third Party Vendor Exploitation and Hacking the Planet! Putting it all Together Building the Final Demo System The Demo Lessons and...

7.6AI score
Exploits0
BDU FSTEC
BDU FSTEC
added 2022/08/22 12:0 a.m.1 views

The vulnerability of the SCADA system AVEVA Edge’s script creation function, related to insufficient warning for dangerous actions, allows a violator to execute arbitrary code.

The vulnerability of the SCADA system AVEVA Edge’s script creation function is related to insufficient warnings about dangerous actions. Exploiting this vulnerability allows a perpetrator to execute arbitrary codes...

7.8CVSS5.8AI score
Exploits0References1
OSV
OSV
added 2022/08/19 9:15 p.m.1 views

CVE-2022-2788

Emerson Electric's Proficy Machine Edition Version 9.80 and prior is vulnerable to CWE-29 Path Traversal: '..\Filename', also known as a ZipSlip attack, through an upload procedure which enables attackers to implant a malicious .BLZ file on the PLC. The file can transfer through the engineering...

7.3CVSS5.8AI score0.00099EPSS
Exploits0References1
ICS
ICS
added 2022/08/16 6:0 a.m.38 views

LS ELECTRIC PLC and XG5000 (Update A)

1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor : LS ELECTRIC, LS Industrial Systems LSIS Co. Ltd Equipment: LS ELEC PLC and XG5000 Vulnerability: Inadequate Encryption Strength 2. UPDATE This updated advisory is a follow-up to the original advisory...

6.5CVSS6.3AI score0.00116EPSS
Exploits0References10
ICS
ICS
added 2022/08/16 12:0 a.m.44 views

Sequi PortBloque S

1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Sequi Equipment: Sequi PortBloque S Vulnerabilities : Improper Authentication, Improper Authorization 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in unauthorized...

9.9CVSS9.8AI score0.00291EPSS
Exploits0References6
BDU FSTEC
BDU FSTEC
added 2022/08/12 12:0 a.m.2 views

The vulnerability of Siemens SIMATIC process control system’s API interface allows a hacker to obtain the password hash.

The vulnerability of Siemens SIMATIC process control system APIs is related to the disclosure of information. Exploiting this vulnerability can allow a remote attacker to obtain the password hash...

6.3CVSS7.7AI score0.00264EPSS
Exploits0References2
ICS
ICS
added 2022/08/11 12:0 a.m.25 views

Siemens SICAM TOOLBOX II

1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SICAM TOOLBOX II Vulnerability: Use of Hard-coded Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability results in full access to the database. 3. TECHNICAL...

6.5CVSS6.7AI score0.00219EPSS
Exploits0References8
Tenable Nessus
Tenable Nessus
added 2022/08/04 12:0 a.m.35 views

Emerson DeltaV Distributed Control System Use of Hard-Coded Credentials (CVE-2022-29964)

The Emerson DeltaV Distributed Control System DCS controllers and IO cards through 2022-04-29 misuse passwords. WIOC SSH provides access to a shell as root, DeltaV, or backup via hardcoded credentials. NOTE: this is different from CVE-2014-2350. - The Emerson DeltaV Distributed Control System DCS...

7.5CVSS5.6AI score0.00254EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2022/08/04 12:0 a.m.51 views

Emerson DeltaV Distributed Control System Use of Hard-Coded Credentials (CVE-2022-29962)

The Emerson DeltaV Distributed Control System DCS controllers and IO cards through 2022-04-29 misuse passwords. FTP has hardcoded credentials but may often be disabled in production. This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350. - The Emerson...

5.5CVSS5.5AI score0.00072EPSS
Exploits0References3
BDU FSTEC
BDU FSTEC
added 2022/08/01 12:0 a.m.2 views

The vulnerability of the mySCADA myPRO system for visualizing and controlling industrial processes, related to the lack of measures for cleaning input data, allows a intruder to execute arbitrary commands.

The vulnerability of the mySCADA myPRO industrial process visualization and control system is related to the lack of measures for cleaning incoming data. Exploiting this vulnerability allows a remote attacker to execute arbitrary commands...

9CVSS8AI score0.00366EPSS
Exploits0References2Affected Software1
OSV
OSV
added 2022/07/26 10:15 p.m.2 views

CVE-2022-29963

The Emerson DeltaV Distributed Control System DCS controllers and IO cards through 2022-04-29 misuse passwords. TELNET on port 18550 provides access to a root shell via hardcoded credentials. This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350...

5.5CVSS5.8AI score
Exploits0References2
Rows per page