55 matches found
Hitachi Energy RTU500 series
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: RTU500 series Vulnerabilities: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could cause a buffer overflow and reboot of...
CVE-2023-28810
Some access control/intercom products have unauthorized modification of device network configuration vulnerabilities. Attackers can modify device network configuration by sending specific data packets to the vulnerable interface within the same local network...
Toyota RAV4 注入漏洞
The Toyota RAV4 is a utility crossover vehicle from Toyota Japan. A security vulnerability exists in Toyota RAV4 2021. An attacker exploits the vulnerability to drive the vehicle by accessing the access control CAN bus after pulling the bumper and reaching the headlight connector...
ABB Relion 650 and 670 Series Improper Input Validation (CVE-2019-18247)
An attacker may use a specially crafted message to force Relion 650 series versions 1.3.0.5 and prior or Relion 670 series versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior to reboot, which could cause a denial of service. This plugin only works with Tenable.ot. Please visit...
Hitachi Energy Relion 670/650/SAM600-IO
1. EXECUTIVE SUMMARY CVSS v3 8.1 Vendor: Hitachi Energy Equipment: Relion 670/650/SAM600-IO Vulnerability: Insecure Default Initialization of Resource 2. RISK EVALUATION Successful exploitation of this vulnerability could hijack existing TCP sessions to inject packets of their choosing or cause...
Johnsoncontrols Metasys Improper Restriction of XML External Entity Reference
XXE vulnerability exists in the Metasys family of product Web Services which has the potential to facilitate DoS attacks or harvesting of ASCII server files. This affects Johnson Controls' Metasys Application and Data Server ADS, ADS-Lite versions 10.1 and prior; Metasys Extended Application and...
Information Leakage Vulnerability in Crypto Controls Configuration Software
QuickControl Configuration Software is a monitoring software used in industrial power and other fields. An information disclosure vulnerability exists in Quick Control Configuration Software. An attacker can use the vulnerability to delete the password field in the project file, bypass the passwo...
Win-911 Enterprise Platform privilege escalation vulnerability
Summary Multiple exploitable local privilege elevation vulnerability exists in the file system permissions of the Win-911 Enterprise V4.20.13 install directory. Depending on the vector chosen, an attacker can overwrite various executables which could lead to escalation of the privileges when...
Researchers Warn of Flaw Affecting Millions of IoT Devices
Researchers are urging connected-device manufacturers to ensure they have applied patches addressing a flaw in a module used by millions of Internet-of-Things IoT devices. If exploited, researchers speculated that the flaw could allow attackers to knock out a city’s electricity or even overdose a...
CVE-2013-7333
A vulnerability in version 0.90 of the Open Floodlight SDN controller software could allow an attacker with access to the OpenFlow control network to selectively disconnect individual switches from the SDN controller, causing degradation and eventually denial of network access to all devices...
CVE-2013-7333: Improper Input Validation
A vulnerability in version 0.90 of the Open Floodlight SDN controller software could allow an attacker with access to the OpenFlow control network to selectively disconnect individual switches from the SDN controller, causing degradation and eventually denial of network access to all devices...
Siemens BACnet Field Panels Security Bypass Vulnerability
BACnet Building Automation Control Network is a data communication protocol for building automation and control networks. A security bypass vulnerability exists in Siemens BACnet Field Panels, where an attacker with network access to an integrated web server ports 80/TCP and 443 /TCP could bypass...
Major Security Vulnerability Found In Schneider Electric ICS Gear
Schneider Electric is grappling with a critical vulnerability found in its flagship industrial controller management software called Unity Pro that allows hackers to remotely execute code on industrial networks. The warning comes from Indegy, an industrial cybersecurity firm. Indegy discovered th...
ABB HART Device DTM Vulnerability
OVERVIEW Alexander Bolshev of Digital Security has identified an improper input vulnerability in the CodeWrights GmbH HART Device Type Manager DTM library used in ABB’s HART Device DTM. CodeWrights GmbH has addressed the vulnerability with a new library, which ABB have begun to integrate. AFFECTE...
[Full-disclosure] CORE-2008-0125: CitectSCADA ODBC service vulnerability
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 Core Security Technologies - CoreLabs Advisory http://www.coresecurity.com/corelabs/ CitectSCADA ODBC service vulnerability Advisory Information Title: CitectSCADA ODBC service vulnerability Advisory ID: CORE-2008-0125 Advisory URL:...