177 matches found
CVE-2023-22331
Use of default credentials vulnerability in CONPROSYS HMI System CHS Ver.3.4.5 and earlier allows a remote unauthenticated attacker to alter user credentials information...
CVE-2023-22324
SQL injection vulnerability in the CONPROSYS HMI System CHS Ver.3.5.0 and earlier allows a remote authenticated attacker to execute an arbitrary SQL command. As a result, information stored in the database may be obtained...
CVE-2023-22334
Use of password hash instead of password for authentication vulnerability in CONPROSYS HMI System CHS Ver.3.4.5 and earlier allows a remote authenticated attacker to obtain user credentials information via a man-in-the-middle attack...
CVE-2023-23575
Improper access control vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker to bypass access restriction and access Network Maintenance page, which may result in obtaining the network information of the product. The affected products and versions are as follows:...
CVE-2023-27917
OS command injection vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker who can access Network Maintenance page to execute arbitrary OS commands with a root privilege. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 a...
CVE-2023-27389
Inadequate encryption strength vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker with an administrative privilege to apply a specially crafted Firmware update file, alter the information, cause a denial-of-service DoS condition, and/or execute arbitrary code...
CVE-2022-44456
CONPROSYS HMI System CHS Ver.3.4.4?and earlier allows a remote unauthenticated attacker to execute an arbitrary OS command on the server where the product is running by sending a specially crafted request...
The vulnerability of the software for creating and managing graphical user interfaces in industrial automation systems like SCADA CONPROSYS HMI Systems lies in the use of a password hash instead of a password for authentication. This allows attackers to exploit this flaw to disclose sensitive information through a “man-in-the-middle” attack.
The vulnerability of the SCADA CONPROSYS HMI System lies in the use of a password hash instead of a plain-text password for authentication. Exploiting this vulnerability allows an attacker, operating remotely, to disclose sensitive information through a “man-in-the-middle” attack...
The vulnerability of HMI/SCADA CONPROSYS HMI, which stems from insufficient verification of incoming requests, allows a hacker to perform an SSRF attack.
The vulnerability of HMI/SCADA CONPROSYS HMI is related to insufficient checking of incoming requests. Exploiting this vulnerability can allow a malicious actor to perform an SSRF attack remotely...
The vulnerability of HMI/SCADA CONPROSYS HMI, related to the storage of account data in plaintext format, allows a intruder to gain unauthorized access to protected information.
The vulnerability of HMI/SCADA CONPROSYS HMI lies in the storage of account data in plain text. Exploiting this vulnerability can allow an intruder to gain unauthorized access to protected information...
CVE-2023-29154
SQL injection vulnerability exists in the CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page...
CVE-2023-28713
Plaintext storage of a password exists in CONPROSYS HMI System CHS versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information ...
CVE-2023-28651
Cross-site scripting vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is...
CVE-2023-28651
Cross-site scripting vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is...
CVE-2023-28657
Improper access control vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user...
CVE-2023-28399
Incorrect permission assignment for critical resource exists in CONPROSYS HMI System CHS versions prior to 3.5.3. ACL Access Control List is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC whe...
CVE-2023-28399
Incorrect permission assignment for critical resource exists in CONPROSYS HMI System CHS versions prior to 3.5.3. ACL Access Control List is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC whe...
CVE-2023-29154
SQL injection vulnerability exists in the CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page...
CVE-2023-28713
Plaintext storage of a password exists in CONPROSYS HMI System CHS versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information ...
CVE-2023-29154
SQL injection vulnerability exists in the CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page...