CVE-2023-28713: Cleartext Storage of Sensitive Information
Plaintext storage of a password exists in CONPROSYS HMI System CHS versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information ...
CVE-2023-28657
Improper access control vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user...
CVE-2023-28713
The CVE-2023-28713 entry concerns CONPROSYS HMI System (CHS) prior to version 3.5.3, where account information for the database is stored in plaintext in a local file. This allows someone with access to the host PC to obtain sensitive data and potentially modify database contents. The vulnerabili...
CVE-2023-28824
CVE-2023-28824 affects Contec CONPROSYS HMI System (CHS) prior to version 3.5.3. The issue is a server-side request forgery (SSRF) vulnerability where an administrator can bypass the query-setting database restrictions and connect to a user-unintended database. Root cause details in connected doc...
CVE-2023-28824
Server-side request forgery vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database...
CVE-2023-29154
CVE-2023-29154 affects Contec CONPROSYS HMI System (CHS) prior to version 3.5.3. The vulnerability is an SQL injection that allows a user with administrative privileges to execute arbitrary SQL commands through specially crafted input on the query setting page. Several sources (including CVE list...
CVE-2023-28657: Missing Authorization
Improper access control vulnerability exists in CONPROSYS HMI System CHS versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user...
CVE-2023-2758
A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time...
CVE-2023-2758
A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time...
Denial of service
A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time...
CVE-2023-2758
Contec CONPROSYS HMI System (CHS) versions 3.5.2 and earlier are affected by CVE-2023-2758: a time-zone mismatch in certain configuration files allows a remote, unauthenticated attacker to deny logins for an extended period. A fix is available in Ver.3.5.3 as reported by the vendor/developer coor...
CVE-2023-2758 Contec CONPROSYS HMI System (CHS) v3.5.2 Denial of Service
A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time...
CVE-2023-2758 Contec CONPROSYS HMI System (CHS) v3.5.2 Denial of Service
A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time...
Contec CONPROSYS HMI System 跨站脚本漏洞
Contec CONPROSYS HMI System is an HTML5-based HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System versions prior to 3.5.3, which stems from a cross-site scripting vulnerabilit...
PT-2023-21222 · Contec · Contec Conprosys Hmi System
Name of the Vulnerable Software and Affected Versions: Contec CONPROSYS HMI System versions 3.5.2 and prior Description: A denial of service issue exists due to a time-zone mismatch in certain configuration files. This allows a remote, unauthenticated attacker to deny logins for an extended perio...
CVE-2023-2758: Improper Control of Interaction Frequency
A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time...
Contec CONPROSYS HMI System 安全漏洞
Contec CONPROSYS HMI System is an HTML5-based HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System version 3.5.2 and earlier, which stems from the presence of a denial of servi...
Contec CONPROSYS HMI System SQL注入漏洞
Contec CONPROSYS HMI System is an HTML5-based HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System versions prior to 3.5.3, which originates from the presence of SQL injection...
Contec CONPROSYS HMI System 代码问题漏洞
Contec CONPROSYS HMI System is an HTML5-based HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System versions prior to 3.5.3 that stems from a server-side request forgery...
Contec CONPROSYS HMI System 安全漏洞
Contec CONPROSYS HMI System is an HTML5 technology-based HMI Human Machine Interface/SCADA Supervisory Control and Data Acquisition software product from Contec Japan. A security vulnerability exists in Contec CONPROSYS HMI System versions prior to 3.5.3, which stems from database account details...