503 matches found
PT-2022-21183 · Siemens · Sinema Remote Connect Server
Name of the Vulnerable Software and Affected Versions: SINEMA Remote Connect Server versions prior to V3.1 Description: A vulnerability has been identified in the affected application, which contains an older feature that allows importing device configurations via a specific endpoint. An attacker...
Siemens SINEMA Remote Connect Server 安全漏洞
SINEMA Remote Connect is a remote network management platform that makes it easy to manage tunnel connections VPNs between headquarters, service technicians, and installed machines or plants.A parameter handling error vulnerability exists in Siemens SINEMA Remote Connect Server, which stems from ...
PT-2022-21187 · Siemens · Sinema Remote Connect Server
Name of the Vulnerable Software and Affected Versions: SINEMA Remote Connect Server versions prior to V3.1 Description: A vulnerability has been identified in the SINEMA Remote Connect Server, where the affected application contains a file upload server that is vulnerable to command injection. Th...
Siemens SINEMA Remote Connect Server 跨站脚本漏洞
SINEMA Remote Connect is a remote network management platform that makes it easy to manage tunnel connections VPNs between headquarters, service technicians, and installed machines or plants.A cross-site scripting vulnerability exists in Siemens SINEMA Remote Connect Server, which could be...
Siemens OpenSSL Affecting Industrial Products
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEMA Remote Connect Server Vulnerabilities: Multiple 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges, disclose...
Open redirect
A vulnerability has been identified in SINEMA Remote Connect Server All versions V2.0. Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks...
CVE-2022-23102
The CVE-2022-23102 entry affects SINEMA Remote Connect Server (all versions
Siemens SINEMA Remote Connect Server 输入验证错误漏洞
Siemens SINEMA Remote Connect Server is a remote network management platform from Siemens, Germany. The platform is used to remotely access, maintain, control and diagnose the underlying network. The Siemens SINEMA Remote Connect Server open redirect vulnerability can be exploited by an attacker ...
Siemens SINEMA Remote Connect Server
1. EXECUTIVE SUMMARY CVSS v3 5.4 ATTENTION : Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEMA Remote Connect Server Vulnerability: Open Redirect 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to use a specially crafted link to...
CVE-2021-39002
IBM DB2 for Linux, UNIX and Windows includes DB2 Connect Server 9.7, 10.1, 10.5, 11.1, and 11.5 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information...
CVE-2021-38931
IBM Db2 for Linux, UNIX and Windows includes DB2 Connect Server 11.1, and 11.5 is vulnerable to an information disclosure as a result of a connected user having indirect read access to a table where they are not authorized to select from. IBM X-Force ID: 210418...
CVE-2021-39002
IBM DB2 for Linux, UNIX and Windows includes DB2 Connect Server 9.7, 10.1, 10.5, 11.1, and 11.5 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information...
CVE-2021-29825
CVE-2021-29825 affects IBM Db2 for Linux, UNIX and Windows (including Db2 Connect Server). The vulnerability could disclose sensitive information when using ADMIN_CMD with LOAD or BACKUP. IBM’s Security Bulletin for CVE-2021-29825 notes affected Db2 LUW versions include 11.1.x and 11.5.x; remedia...
Siemens SINEMA Remote Connect Server Access Control Error Vulnerability
Siemens SINEMA Remote Connect Server is a remote network management platform from Siemens, Germany. The platform is used to remotely access, maintain, control and diagnose the underlying network. An access control error vulnerability exists in SINEMA Remote Connect Server, which can be exploited ...
Unspecified Vulnerability in Siemens SINEMA Remote Connect Server
Siemens SINEMA Remote Connect Server is a remote network management platform from Siemens, Germany. The platform is used to remotely access, maintain, control and diagnose the underlying network. A security vulnerability exists in Siemens SINEMA Remote Connect Server versions prior to 3.0 SP2,...
CVE-2021-37193
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.0 SP2. An unauthenticated attacker in the same network of the affected system could manipulate certain parameters and set a valid user of the affected software as invalid or vice-versa...
CVE-2021-37193
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.0 SP2. An unauthenticated attacker in the same network of the affected system could manipulate certain parameters and set a valid user of the affected software as invalid or vice-versa...
CVE-2021-37192
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.0 SP2. The affected software has an information disclosure vulnerability that could allow an attacker to retrieve a list of network devices a known user can manage...
CVE-2021-37191
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.0 SP2. An unauthenticated attacker in the same network of the affected system could brute force the usernames from the affected software...
CVE-2021-37183
A vulnerability has been identified in SINEMA Remote Connect Server All versions V3.0 SP2. The affected software allows sending send-to-sleep notifications to the managed devices. An unauthenticated attacker in the same network of the affected system can abuse these notifications to cause a...